DR #37 - Carver M-400 Repair

Duality Repair
132 followers
Mar 12, 2025
This M-400 suffers from a "ticking" noise, audible through the speakers and withiin the unit itself. During this video, I check the triac, the diac, multiple resistors and multiple caps. Ultimately, I'll replace all caps.
- 1uF @ 50V (x2) - 493-17436-1-ND
- 1uF @ 100V (x2) - 493-11540-1-ND
- 4.7uF @ 35V (x2) - 493-16017-ND
- 10uF @ 35V (x3) - 493-1314-ND
- 22uF @ 35V (x4) - 493-1315-ND
- 22uF @ 35V (x3) - 493-1315-ND
- 330uF @ 16V (x2) - 493-1521-ND
- 2,200uF @ 25V (x6) - UVY1E222MHD-ND
- 4,700uF @ 80V (x2) - 493-8967-ND
hi everyone welcome to duality repair
this is carver's m400 amplifier
this one is suffering from a problem
that even carver was aware of and they
called it ticking
so although this unit does pass an audio
signal
you can hear an audible ticking coming
from with inside the unit and also to a
certain extent through the speakers as
well
so i'll plug it in and i'll put the
microphone closer to the unit so you can
hear what i'm talking about
like other carver amplifiers the m400 is
triac controlled
meaning it uses a triac to regulate the
power supply
critical to proper power supply
performance is proper triac firing
and as you can see from the service
manual improper triac firing or what
they call rough
triac firing can lead to the ticking
noise that we're currently experiencing
so you can see we have some graphs here
as well and we have an example of good
and symmetrical firing as well as bad
and rough firing
now i've already tested the triac in
this module and i've also compared it to
a triac in another carver module
and this one certainly does appear to
have a problem uh firing the triac
so let's go to the scope all right
here's our setup
i have channel a of my scope hooked up
to mt2
of the triac from the tfm45 that i
recently repaired and channel b
is hooked up to mt2 of the triac of the
m400
let's start with the tfm45 as that is
our good example
if we look at the trace on the scope for
the tfm45 we can see it's pretty close
to matching the good or symmetrical
graph from the service manual the triac
is firing from about zero volts to just
a little bit past
the peak on the positive half cycle and
again from zero volts and just a little
bit past the peak on the negative half
cycle as well so very very close very
symmetrical
very clean and smooth firing so now i'll
plug in the m400 so we can compare
all right so the m400 signal is now on
the bottom and hopefully you can tell
just how glitchy that triac is firing
even if i change the trigger source from
channel a to channel b
which is the m400 it certainly doesn't
make the m400 signal look any better and
it really just screws up the tfm45
signal
so we can see there's definitely a
problem with the way the triax firing
now it's not necessarily the triac
that's causing this
it could be something else associated
with the regulation circuitry
due to how tightly packed everything is
in this unit it's very hard to test
in place so i'm going to start
disassembling everything so we can test
i was successful in completely
disassembling the unit it's made up of
just three boards the power supply board
two nearly identical amplifier modules
and of course the power transformer
everything on this unit seems to be
original so at the very least
i'm going to replace all of the
electrolytics now i could get lucky and
that might fix the ticking issue
but due to the amount of time and effort
that it takes to disassemble this unit
i'm not going to gamble on that and so
i'm going to do everything i possibly
can now while it's disassembled
before i reinstall and test and so next
i'm going to look at some of the
critical components that are inside
the regulation section of the supply
the first thing i'm going to test is the
triac and i'll tell you up front that
regardless of how it tests i am going to
replace it with this brand new triac
i'm going to do that because again this
is probably original
which means it's nearly 40 years old and
because the triac is so critical to
proper
power supply performance
so it does detect the triac it gives you
the pin out
it gives you the trigger current range
so in this case 10 to 25 milliamps
it gives you the gate voltage at which
it triggered so 0.98 volts at 25
milliamps and it also gives you the load
conditions as well
so this triac does test good but again
due to its age and due to the
criticality to the proper performance of
the power supply i am going to replace
it with this
and i will put the list of part numbers
that i use during this
repair in the description i'm sure that
if i didn't measure and compare the new
triac to the old
i'd get a lot of comments
so we have identical trigger current
range 10 to 25 milliamps
close gate voltage 0.94 volts versus
0.98
on the original and of course the same
load conditions
so this should work just fine i'm going
to move backwards from the triac now and
check the diac
with a multimeter in circuit pretty much
the only thing i can do is verify that
it's not shorted
no it doesn't look to be shorted
now i'm going to check these three
resistors
here's our 10 pretty close at 132k
here's r9 almost dead on at 99k
and here's r57 right on the money at 51k
so these three resistors check out
here's the last component that i was
seriously concerned about in the power
supply section this is oc1
which is an ldr or light dependent
resistor
it wasn't really measuring as i thought
it should when it was in the circuit so
i removed it and i tested it and it's
actually testing normally
so we'll go through that now what this
is is it's an led on this side
and i have that connected to my power
supply and a light dependent resistor on
this side
as you increase the current through the
led you decrease the resistance of the
light dependent resistor
so i'll slowly increase the current
through the led now
and we'll watch the resistance go from
open
and it'll gradually decrease so it'll
take a minute to turn the led on we need
about
1.6 volts to turn the led on
and there it goes i kind of overshot it
there so we're down to 2k already on the
resistor
i'll gradually increase the current and
you can see the resistance is gradually
decreasing
so this ldr seems to be functioning just
fine
everything that i was really concerned
about seems to check out again you can't
really
fully test the diac with just a
multimeter so i am going to replace that
just in case
that was a problem i'm going to start
removing all of the electrolytics and
i'm going to do a more thorough
inspection of the power supply board
if i happen to find anything i will show
you what i found if not i'll just come
back when i replace the caps
the triac and the all right i'm
completely done recapping the power
supply and i think it turned out really
well
in the course of recapping this i've
also discovered a significant problem
a problem that i believe is the source
of the ticking so i'll go over that now
here are the two filter caps for the
plus and minus 80 volt
rails on the left i'm measuring
capacitance and you can see we're in the
nanofarad range
while these caps should be 4000
microfarads on the right i'm measuring
the esr and you can see the esr of this
cap
is beyond the measurable limit of the
meter so these caps are just toast
they've been effectively useless in this
circuit for who knows how long
so how could this cause our ticking
issue well of course the purpose of a
filter cap is to filter or smooth out
pulse dc
before it sends it out to the rail and
the regulation circuitry samples all
three rails plus 12 plus 50 and plus 80
volts so
it's assuming that it's going to have
solid dc coming into that regulation
circuitry
since these caps aren't functioning
properly we're sending pulse dc
to the regulation circuitry on the 80
volt rail and that's definitely going to
screw up our regulation
i have no doubt that if these caps
aren't the only factor in the ticking
they're definitely significant factor
all right i've finished recapping both
of the amplifier modules
there are only four caps on each
everything else looks to be in really
good shape on these so i didn't touch
anything else
i did clean off the excess thermal
compound or what i could anyway
i also cleaned off the excess thermal
compound on the chassis itself
and i think i'm ready to go ahead and
reinstall everything before i reinstall
the output transistors i am going to
clean off the thermal compound
i'll test each one of these to make sure
none of them are shorted and then of
course reapply new thermal compound
before installing
and just like that everything is back
together and i think it looks really
nice
the unit's plugged in and it's virtually
silent no more ticking so we know that
those two filter caps were definitely
the source of the issue
i have my multimeter connected to the
collector of one of the output
transistors
and as you can see we're reading very
close to 75.5 volts dc
and that's exactly what the spec is to
get there you adjust this little pot
here rp1
i've already verified the biases are in
spec as well so before i put the covers
on let's go back to the scope and take a
look at the trace of the triac firing
all right our triac firing now looks
much healthier
so let's get the covers back on and
we'll do a final sound test
okay i've been listening to this for a
while now and it sounded really really
good so this one is all done
thanks for watching
you