DR #71 - Repairing a Dead Parasound A23+

Duality Repair
132 followers
582 Video Views·May 25, 2026
In this video, I document the troubleshooting and repair of a Parasound A 23+ power amplifier that failed to power up properly. I show the symptoms, walk through the troubleshooting process and circuit analysis, identify the failed component, replace several critical components, and finish with testing and verification of proper operation.
AI Generated·May contain errors
Video Summary
AI GeneratedThis video demonstrates the repair of a Parasound A23 plus amplifier that failed to power up. The technician identifies a faulty relay (RY3) as the primary cause, replaces it along with other aging components, and verifies the repair through signal and power testing. The process concludes with a detailed explanation of the amplifier's power-up sequence and the logic used for troubleshooting.
This is a Parasound A23 plus amplifier with a power-up issue. I've already done a significant
amount of troubleshooting, so for now I'll show you the symptom. I'll show you which component I
suspect. I'll remove and test that component. If it does indeed test bad, I'll replace it along
with a few key other components. I'll put it all back together and we'll see if the issue is
resolved. At the very end I'll go over a bit of the circuit as well as some of my troubleshooting
steps. I'll power it up and let's listen and watch. Immediately we can hear one or more of the
power supply relays engage, but the speaker protection relays never engage,
and we also don't see any illumination from these two channel LEDs. I believe these should
be either white or blue if the channels are healthy, or red if they're not, but we get nothing
at all. This is a pretty amp, isn't it? Red transformer, black PCB, everything is clean and
tight. I'm very much looking forward to working on this. My suspect is right here. This is a 12
volt relay, specifically RY3 in the power supply section. Unfortunately, there's no removable
service panel on the bottom of this unit, so everything has to come out from the top. I'm
not sure how to do that yet, but I'll figure it out. RY3 has been removed. It's a 12 volt
double pull, double throw from Panasonic. Before I test this, let's see how a known good relay
should perform. That's what I have here. When the relay is de-energized, we should have one
set of contacts shorted and the other open. When I apply 12 volts to the coil, these conditions
should reverse. So let's watch that happen. You'll hear the click as I apply 12 volts,
just like that. This is RY3. We have the same starting conditions. I'll apply 12 volts to the
coil now. We can hear it engage. One set of contacts does flip from short to open, but the
never flips from open to short. We do indeed have a bad relay. I'll check the other side for
completeness. The other side shows the same fault. This relay is no bueno. While I'm at it, I'm also
going to replace RY4 and RY5. They're the exact same part number and age as RY3, and direct
replacements are still available. They're only a few dollars, so I might as well. I'm also going
replace all eight of these bulk capacitors. These are 6800 microfarad at 80 volts, and they're all
bulged to a certain extent. All of the old components have been removed, and the new
components have arrived. Here are the OEM part numbers. Let's replace these relays and bulged
caps. It's all back together again. I have the lights dimmed down low. Here we go. I certainly
heard at least one more relay engage this time, and we have two blue LEDs in the front. That's a
good sign. Seems to have powered up properly this time. Let's see if it works. I'll start with a
simple signal clarity test. I have a two kilohertz sine wave at each input. Take a look at these
traces on the scope as I increase the amplitude. Yeah, they look great. No problem there. Next, I'll
check the frequency response with a square wave. Those look great too. And finally, I'll verify the
power output. This amp is rated for 160 watts into 8 ohms. That's about 100 volts peak-to-peak.
At 20 volts per division on the scope, that's going to be five divisions. That's what we're
looking for. Here we go. That's two divisions or 40 volts peak-to-peak. That's four divisions or
80 volts peak-to-peak. That's about five divisions right there, and there's clipping right there.
So yeah, we're at least at 160 watts. Here's a block diagram showing the relevant sections of
the circuit. First, we'll go over the proper power-up sequence, what this should look like
when you turn it on, and then we'll go over what I actually saw and how that led me to
relay RY3. We'll start with our 120 volts AC in up here. Once the rear power switch is turned on,
it has two paths. We'll go over the second path in a minute. First, it'll hit this standby
transformer, which should produce 20 volts of AC. That'll be rectified, which should produce
something like 27 volts of DC. This then has two paths. First, it'll energize relay RY5,
and second, as soon as that front switch is turned on, it'll energize relay RY3.
Now let's come back to our second AC path. First, if RY4 was energized, it would travel through
these contacts, but it's not yet, so it'll travel through this inrush current limiter.
It'll then travel through the contacts of RY3, contacts of RY5, and finally, it should energize
the main transformer. Once this is energized, it will produce three voltages, 13, 42, and 42.
The 13 volts AC will be rectified, which should produce something like 17 volts of DC,
and this will energize relay RY4. Now that RY4 is energized, we can bypass this inrush current
limiter, travel through the contacts of RY4, 3, and 5 for sustained power. But what did I see
and measure? When I turned the rear switch on, I heard the audible click. That would have been
relay RY5 being energized. When I turned the front switch on, I heard another audible click,
which would have been relay RY3 being energized. Not only that, but I did measure voltage at both
coils, indicating this entire section of the circuit was working properly. From there, I look
for DC voltage at the coil of relay RY4, so here, and saw nothing. I then measured the input to this
bridge rectifier, looking for something like 13 volts AC, and saw nothing there as well. So from
there, I went to the main transformer. I looked for these 13 volts, 42 volts, and 42 volts directly off
the secondary of the main transformer and saw absolutely nothing. I then measured the input
to the transformer right here, saw nothing. I then measured the input to relay RY5 here,
and saw nothing. And finally, when I measured the input to relay RY3 right here, I did see 120 volts
of AC, which led me to believe that one or both of the contacts of RY3 were bad. That'll be it
for this Parasound A23 Plus. Thanks for watching.