This is the Proton AP-1000 preamp. In
the last video, I resolved an odd issue
with the tone control circuit. In this
video, I hope to resolve an issue with
the headphone circuit. Let's take a look
at what that issue
is. No output from the right channel.
Left channel seems to work just
fine. Thankfully, this has nothing to do
with dirty switches, potentiometers,
relay contacts, or anything like that.
There's an actual issue that resides in
the right channels headphone circuit
that needs to be troubleshot and
resolved. So, let's get after it. Here's
the schematic for the right channels
headphone circuit. Before we look at
this more closely, I did want to show
you that we do indeed get a signal
coming into the circuit. So, the input
is over here on the left. We already
know there's nothing coming from the
output on the right. So, I have my
oscilloscope probing this point here,
the base of this input
transistor. And there it
is. On the schematic, I've highlighted
the signal path from input to output in
orange. And looking at the bottom of the
board, I can tell that some of these
components have been replaced, likely in
an attempt to resolve this issue. That's
going to be all of these components
highlighted in orange as well. I'm not
sure if this was done by the current
owner, a former owner, a technician at
some point. That's irrelevant. Instead
of using the scope for this one, I'm
going to use the multimeter and measure
voltages at critical points around the
circuit. So I'll start with the rail
voltages which according to the
schematic should be somewhere around
plus or - 32 volts and then I'll look at
other critical points around the
circuit. I'll document it on the
schematic. We'll come back and analyze
it and see if that gives us a path
forward. Let's review the circuit. Our
signal comes in from the top left. It
first hits this input transistor Q 602.
This is responsible for current gain
which will drive our drive transistor
Q604. Q4 is responsible for voltage gain
which will ultimately drive our output
transistors Q8 and Q 606. And our signal
exits from the top
right. We'll start with the rail
voltages. These are very near what we'd
expect. Negative 33.2 at the top and
positive 32.8 at the bottom. There are
only two voltages referenced on the
schematic. Positive 0.9 volts at the
output and positive 0.63 volts very
specific at the emitter of our input
transistor Q
602. If we compare just those two
voltages to our actual measurements, we
see something is obviously wrong. - 33.2
volts at the output, - 32.6 at the
emitter of Q 602.
Everything else appears to be wildly
wrong as well. But the most concerning
measurements are around these two
transistors, Q 604 and Q
608. It's obvious that we have the rail
voltage at the emitter of Q 604, which
is - 33.2
volts. From that, we'd expect somewhere
between 6 and 7 volts more at the base,
but we only get - 33.1 volts. Only
1/10enth of a volt drop. Something's odd
there. And even more concerning is
around Q
608 we have - 33.2 volts at the emitter
and from that we'd expect somewhere
around6 to.7 volts less at the base. We
actually get a more positive voltage -
33.1. So what is going on? I think I'd
like to focus my attention on Q 604 and
Q
608. This is a tricky one, but I believe
I figured it out. Let's remove Q 604 and
Q 608 just to be sure.
Here are the two suspect transistors.
One is an NPN and that's a
BC546B. The other a PNP and that's a
BC556B. These are actually both
measuring perfect somewhere around 0.7
volts from base to emitter and base to
collector for both transistors. They're
also both reading open in the directions
that you'd expect. So where's the
problem? The problem lies in the
installation.
The PNP was installed in Q 604's
location and the NPN in Q 608's
location. That could definitely be the
cause of this issue. Since these are
both still reading properly, let's try
installing them in their proper
locations and see if that resolves our
issue.
Before checking for a good output on the
scope, let's build the suspense just a
little bit. I want to rememeasure one
voltage. The output voltage right here.
We're looking for somewhere around 0.9
volts and we were at -3.2 before. I'm
going to measure at the junction of R
610 and R
612. Let's see what we get.
1.022 volts. Much much better. I'm
liking the way things are looking so
far. Let's go to the
scope. All right, everyone, place your
bets. Did that do
it? It sure
did. Fantastic.
So, what can we make from all of this?
My guess is that output transistor Q 608
shorted. And with it, it took the
emitter resistor R612 as well as the
drive transistor
Q604. Whoever did the work to repair
this part of the circuit did a good job,
except they accidentally put these two
transistors in the wrong position. A
very simple mistake to make given their
location on the board. With these other
components being replaced, diode D604,
D602, and resistor R610, I am very
surprised that the other output
transistor Q606 is still original and
measuring okay. Out of precaution, I may
replace this.
Anyway, that's it for the repair.