DR #54 - Audio Amplifier Repair - Carver TFM-15CB

Duality Repair
132 followers
2 Video Views·Mar 12, 2025
This dead Carver TFM-15CB amplifier was sent in by a viewer. Follow along as I repair, upgrade, and test it.
Parts Used:
*** Lamp Replacement ***
https://www.ebay.com/itm/125400378382?_trkparms=amclksrc%3DITM%26aid%3D777008%26algo%3DPERSONAL.TOPIC%26ao%3D1%26asc%3D20240131095853%26meid%3De42b5c687fb14db4b6ead048c4322821%26pid%3D101949%26rk%3D1%26rkt%3D1%26itm%3D125400378382%26pmt%3D1%26noa%3D1%26pg%3D4375194%26algv%3DRecentlyViewedItemsV2%26brand%3DCarver&_trksid=p4375194.c101949.m162918&_trkparms=parentrq%3A1eddd9e71900ab9c8cc6dbf5fffe924a%7Cpageci%3Acd9ccfbd-2b87-11ef-928d-2e6b799f056a%7Ciid%3A1%7Cvlpname%3Avlp_homepage
*** Bulk Capacitors ***
https://www.digikey.com/en/products/detail/cornell-dubilier-knowles/381LX153M063A052/5430418
this is a Carver model TFM 15cb power
amplifier and it's not working properly
I'll power it up to show you what I
mean so my lights flickered a bit and I
can hear a slight hum from the
Transformer but other than that we have
no life there's no lights or movement
from either meter and the protection
relay never
engaged I do have the schematics and I
have a multimeter so I'm going to get
this
fixed after a visual inspection inside
nothing appears to be obviously damaged
however this fuse on the bottom is
open these two fuses above it are just
fine so let's go to the
schematic here's the schematic for the
entire amplifier and it's a little hard
to read so you might have to take my
word for this here's our open fuse
f003 it's leaving the power supply board
here and it's a positive 14 Volt signal
it's going in two different directions
first direction is up here it's feeding
the protection circuit and the second
direction is here it's the supply
voltage for both meter lamps so these
are the two areas that I'm going to
focus on the first thing I'll do is to
look for a short between the 14v rail
and ground this blue wire here is the
14v signal from the power supply so I'll
measure the resistance between this wire
and ground convenient place for that is
this heat sink right
here we're measuring in the mega ohm
range so there is absolutely not a short
between the 14v rail and ground this
doesn't completely rule out the
protection circuit but it is a really
good start so I'm going to move on to
the meter
lamps now I'll test the resistance of
each meter's lamp we'll start with this
one on the left the manual doesn't tell
me what this should
be this one's reading 15.4 ohms seems
low but reasonable let's check the right
meter
this is reading 6.1 megaohms effectively
this is an open filament so this lamp
wouldn't be working at
all I have a theory of what could have
happened let's do some more
testing my thought is as the lamp in
this right meter started to fail it drew
excessive current in the 14v circuit
causing our fuse f003 to blow so what
I've done is I've replace this fuse with
an exact replacement 250 volts at 1 amp
I've disconnected the connection between
the power supply and the meter lamps and
I've tied my multimeter in series with
the 14v circuit so as I power it up we
can monitor the current in that circuit
so let's see what
happens so we're drawing negligible
current in that circuit just 6 milliamps
and hopefully you could hear it but the
relay did engage so I think my theory
was proven correct the next question is
are these meters
serviceable here's the meter bracket and
and it was actually really easy to get
this out of the
amplifier start by removing these two
connectors and then remove the screw
from either side of this bracket and it
slides right out each meter was glued to
this bracket and the glue is starting to
disintegrate so we'll have to fix that
and each back plate looks to have been
glued to the inside of each meter as
well and that's starting to disintegrate
so hopefully we get in these and fix
that to get in these I think all I have
to do is to remove the tape covering all
of these edges and Corners I'm not
positive but I'm going to start with
that yes the meters are definitely
serviceable it is as simple as removing
the tape between the front cover and the
meter
backing the lamps are right in front and
they're soldered on either side so it
should be very simple to remove and
replace I have a power supply connected
to this lamp with 7 volts and it's
drawing about 50 milliamps appears to be
working just fine I have another power
supply connected to the meter and as you
can see as I increase and decrease the
voltage the needle is rising and falling
so this appears to be working
well I did the same thing on the right
meter and that seems to be working as
well of course the lamp in the right
meter is
nonfunctional and so I need to reach out
to the owner and see what he wants to do
about that while I wait to hear back
from him I'm going to test the rest of
this unit and see if there are any other
problems with it I have a 1 khz 1vt sine
wave at at the input and my input level
for each channel is turned all the way
up so let's take a look at the scope and
see what we
got two very
clean and very even sine waves so I
think this unit is actually in good
shape but everything is original so
let's see what other kind of work we
might want to
do this is the power supply board and
there's not a lot going on here
obviously I've already replaced the 1
amp fuse I'm also going to clean this
glue off and maybe reapply some new glue
if I find that it's necessary and I'll
change these to electrolytic capacitors
that's about it the power supply board
is done I replaced both electrolytics I
cleaned off all of that old glue and
applied some new electronic grayed
silicone I touched up the solder on all
five of these Taps from the Transformer
some of them were pretty loose so they
needed some fresh solder and then I
perform just a general cleaning of the
entire board let's move on to the
amplifier board on the amplifier board I
plan on replacing all of the
electrolytics including the main filter
capacitors here these are actually
underrated they're 15,000 microf at 50
volts and they're being fed by plus and
minus 52 volt rails so I'm pretty
surprised that these lasted as long as
they have in addition to that I'm going
to clean and replace the thermal
compound for all of the heat sink
mounted transistors there's five on this
heat sink five on this heat sink and
then four in the middle
here and the relay ideally I'd replace
this with something new but I'm not sure
I'm going to be able to find a suitable
replacement so I'll probably pull it and
clean it to the best of my ability that
should be
it I'm all done with the work on the
amplifier board I've replaced all of the
electrolytic capacitors on the board
including the main capacitors here these
are now 15,000 microfarad at 63 volts so
they're properly rated for the 52 or so
volts they'll see I added some electron
grade silicone in between the two
capacitors to help keep them stable and
I pulled and cleaned the contacts of the
relay ideally as I said I'd like to
replace this with brand new but I
couldn't find any exact Replacements so
I decided to pull and clean the contacts
and I've tried various methods in the
past of cleaning relay contacts with
various success but the most interesting
method that I've ever heard of is to use
a pencil eraser and so I tried that for
the first time on this relay and it
seemed to work perfectly cleaned up just
about 100% of the oxidation that was
seen on the relay contact so I think
this relay will last much much longer
than it would have so I think the
amplifier board turned out really great
I'm ready to move back to the
meters based on past experience in this
channel I know many of you are going to
hate this but I could not find good
replacements for these lamps and so I'm
going with these
LEDs at the time of this video there
were only $8 for the set on eBay which
is pretty good deal and they have their
own built-in diodes and resistors so all
you have to do is solder them on just
like the original lamps and they're
going to work just fine so it's time to
put everything back
together it's all back together but
before we start testing let's clean the
potentiometers
The Meters look really nice but let's
see if this carver can hit its rated
output power of 100 Watts so we'll turn
it up we'll check the view meters and
then we'll go up and take a look at the
scope so dead center of the dial is one
watt there's 25 watts and we'll quickly
go to about 100 watts and we'll go up
and take a look look at the
scope at 100 watts into an 8 ohm speaker
or 8 ohm load we're looking for 80 volts
Peak to Peak at 10 volts per division on
my scope that's going to be the complete
height of the screen so I'll turn both
channels all the way
up and we'll see what we
get pretty much exactly 100 Watts
fantastic
that'll do it for this Carver TFM 15cb
thanks for watching