Lecture 20: Tutorial 4

IIT Roorkee July 201
61 followers
2 Video Views·Dec 1, 2023
Hello everyone, now we will have a tutorial session and in this class we will solve some
numerical problems based on our last four classes.
Problem number one statement is one gram of a MSW sample is heated at 105 degree centigrade
for 24 hour and the weight of the dried material is found as 0.9 gram which is further heated
in a furnace at 950 degree centigrade for 7 minute in absence of air by putting the
lid of the crucible.
The weight loss is found at 0.3 gram, the remaining material is cooled with lid cover
when the temperature reaches to ambient temperature its lid is opened and it is further heated
in an oven at 750 degree centigrade for half an hour in presence of oxygen.
After cooling the material the residual mass of the material is found as 0.14 gram.
Determine the moisture content, volatile matter, ash and fixed carbon of the waste.
So this problem is a proximate analysis a case of proximate analysis and we can solve
it as per our discussion in the previous class.
So here we have initial mass is equal to 1 gram and then moisture content is how much
the first one is moisture content which is heated at 105 degree centigrade for 24 hours.
So the dried material is 0.9 so the remaining 1 minus 0.9 so that is our loss.
So that is the moisture so 1 minus 0.9 divided by 1 into 100 so 10 percent.
So 10 percent moisture we are getting then heating at 950 degree centigrade for 7 minute
that loss will be related to the volatile matter.
So volatile matter content is equal to 0.3 because this loss is 0.3 directly given.
So 0.3 by 1 into 100 so that is equal to 30 percent.
And after that after heating at 750 degree centigrade for half an hour in presence of
oxygen the amount which is remaining that is our ash content.
So the ash content is 0.14 by 1 into 100 so 14 percent.
Now by difference we will get the fixed carbon.
So fixed carbon is equal to 100 minus ash content minus volatile matter content and
minus moisture 100 minus moisture content minus volatile matter content minus ash content.
So we are getting 46 percent.
So fixed carbon is 46 percent.
So problem number 2 the statement is an industrial wastewater is tested for measuring BOD 5 value.
The wastewater is diluted 100 times with dilution water before it is used in the test.
The DO of 1 real and blank sample are determined which is 10 ppm other 2 BOD bottles filled
with real and blank samples are incubated for 5 days at 20 degree centigrade.
After 5 days the DO value of the real and blank samples are found as 3 ppm and 9.5 ppm
respectively.
Calculate the BOD 5 of the original wastewater sample.
If 5 ml of microbial seeds are used in the preparation of 300 ml dilution water how the
BOD value will differ.
So this is the problem based on the determination of BOD.
So we have the formula.
So BOD 5 in mg per liter equal to D into DO t equal to 0 minus DO t equal to 5 for sample
minus DO t equal to 0 minus DO t equal to 5 for blank where D is the dilution factor
in this case 100 times dilution.
So D is equal to 100 and DO t equal to 0 for sample that is equal to 10 ppm and it
is given this is for both real sample and the blank test bottles and then DO t equal
to 5 for real sample test is also given that is equal to 3 ppm and DO t equal to 5 for
blank test is 9.7.
So BOD 5 in ppm is equal to D into DO t equal to 0 minus DO t equal to 0 for the sample
as given here minus DO t equal to 0 for the blank minus DO t equal to 5 for the blank
so 9.7.
So this is the formula and we are getting the value of 670 ppm.
For the second case when seeding is done in that case D is the dilution factor and F is
there another factor is there that we have to consider.
So F is the ratio of seed volume in dilution solution to seed volume in BOD test on seed
and normally it is near to 1 we have discussed in our previous class.
Now here we will see so as per the statement seed volume in 200 ml dilution water is 5
ml and for 100 time dilution 3 ml real waste water sample is added with 290 ml of dilution
water.
So 297 plus 3 that is equal to 300 ml you are getting.
So this is our sample this is diluted water.
So the volume of seeds in the real public test sample is equal to how much 5 divided
by 300 into 297 because seed volume in 300 ml we have 5 ml of seed volume 300 ml dilution
water contains 5 ml of seed volume.
So 297 ml will contain 5 divided by 300 into 290 ml of seed volume.
Therefore we are getting here F equal to 5 which is available in the which is available
in the dilution solution 300 ml dilution solution that is equal to 5 ml.
So 5 divided by 5 into 297 divided by 300.
So 5 into 300 by 5 into 297 that is equal to 1.01.
So that is why F is near to 1 we have mentioned.
So in this case BOD will be slightly different from the first case that will be we have to
multiply it by 1.01.
So we have 100 into 10 minus 3 minus 10 minus 9.7 into 1.01 that is equal to 669.1 ppm.
Problem number 3 the statement is 2 gram of a dried agricultural waste is leached with
benzene and ethanol mixture 2 is to 1 volume by volume at 60 degree centigrade for 3 hour.
After leaching the residue is dried in a hot air oven at 105 degree centigrade to a constant
weight of 1.8 gram.
This dried material is put in a flask containing 150 ml of N by 2 NaOA solution.
The mixture is boiled for 3.5 hour with recycled distilled water.
After this the residue is washed with distilled water till all the sodium ions are removed
and dried to a constant weight of 1.3 gram.
Determine the extractives and hemicelluloses content of this waste on dry basis if moisture
content of the waste is 15 percent determine these values with respect to original sample.
So initial weight 2 gram it is given weight after extractives is 1.8 gram it is given
because the first operation is related to the exclusion of the extractives.
So we are getting 1.8 gram.
Now weight after hemicellulose separation is also 1.3 gram the second step which was
given that is to remove the hemicellulose.
So that is equal to 1.3 gram extractive content we are getting MO minus M1 by MO into 100.
So this formula we have discussed in the previous class.
So here we are getting 2 minus 1.8 into 100 divided by 2 10 percent and hemicellulose
content M1 minus M2 into 100 divided by MO.
So 1.8 minus 1.3 into 100 divided by 2 so 25 percent.
And with respect to original waste material the extractives and hemicellulose contents
are say 85 by 100 into 10 percent 8.5 percent and hemicellulose content 85 by 100 into 25
percent that is equal to 21.25 because it has some moisture content.
So if we consider it on original waste material basis then these values will be reduced to
some extent.
Next problem 4 COD analysis of a waste water sample is carried out through chemical method
using n by 10 potassium dichromate solution as reducing agent excess dichromate is titrated
against ferrous ammonium sulphate 100 ml of waste water sample is used the titer value
of ferrous ammonium sulphate are 50 ml and 75 ml for original sample and blank sample
respectively.
Determine the COD of the sample assume there is no interfering element in the sample.
So this is a problem of COD analysis and for this we have the formula COD is equal to 8000
into b minus s into n divided by sample volume.
So here 8000 into b is nothing but b is the volume of FAS used in the blank sample as
provided here 75 ml and s is nothing but the volume of FAS in the original sample and
n is the normality of the FAS.
So here 75 minus 50 and normality is given n by 10 so n by 10 0.1 divided by sample volume
is 100 ml so we are getting this equal to 200 mg per liter.
Problem number 5 statement is 1.5 gram of a solid waste is kept in the bomb of a calorimeter
the initial and final temperatures of water in bucket are 23 and 28 degree centigrade
respectively.
The bucket wash is titrated against 10 by 10 Na2CO3 and the titer value is 2.9 ml.
Sulphur content in the solid waste is 2 percent per 45 C10 NiCr wire is used to ignite the
waste sample and 4 centimeter of the wire is fused.
The water equivalent of the calorimeter is 2402 calorie per degree centigrade hydrogen
content of the waste is 8 percent calculate the Hsv and Lsv of the solid waste.
So this is the problem related to determination of heating value and we will discuss and we
will solve it.
So to understand this we will have some discussion on the principles of the determination of
heating value.
Say to determine the heating value initially small amount of material say 1 gram is taken
in a bomb calorimeter and it is combusted and the heat released during the combustion
is taken up by some water and the temperature rise in the water and the bomb calorimeter
material is measured.
That means the heat given up by the material due to the combustion is taken up by the water
and the bomb material.
So this is the principle and by that way we by measuring the temperature difference we
can calculate how much heat is released during the combustion of unit mass of the solid waste
and we can determine the heating value and that heating value in this case is high heating
value because in this case the small amount of material is used and excess oxygen is provided
for complete combustion and then the flue gas which is generated that is again cool
down because although local temperature is very high but the volume of the heated gas
is very less and outside water volume is more.
So the almost all heat is transferred to the water and into the bomb material and there
is slight temperature gain.
So we are assuming that since the temperature is below 100 degree centigrade so all moisture
produced during the combustion of the material is already converted to water.
So the amount of heat which is we are getting or we are able to recover that is the total
heat or the high heating value we are getting through this instrument.
So this is the photograph of the bomb calorimeter.
So here the crucible the weighted amount of material is put here so it is around 1 gram.
So after that this is put into this bomb and after putting it here the lid is tightened
and then from this we have some connection one way valve where we can send oxygen and
pressurize it.
After that then we put it inside this water and in this water bucket we put some water
around 2 liter water and then this is put inside this calorimeter and where this some
firing arrangement is there.
So when the material is there, there is some filament so these two end we have for electrical
correction so an electrical electricity will be provided so this filament will be burned
and the material will catch fire.
So when this material will catch fire combustion will take place and heat will release and
that heat will be dissipated through this bomb material, bomb wall to the water inside
this bucket and this temperature will be measured by this temperature measurement device.
So this is the principle which is followed in the bomb calorimeter.
Now you will see by the experiment which I have mentioned here so after putting it inside
we will start firing so initially the temperature of this calorimeter will increase and it will
attain a constant value.
So there will be some differential temperature we can get it will be coming into equilibrium
within few minutes and then we will be getting the del T value.
So we will be calculating ms theta so that is equal to mass into specific heat into del
T so that will be the heat taken by the water body and this one bomb.
So that will be following to measure the heat released by the combusted material.
So after this experiment the following data should be available at the completion of test
in an adiabatic calorimeter that is T a temperature at time of firing connected for thermometer
scale corrected for thermometer scale error.
So we have to correct if there is any error in the thermometer measurement and T f is
the final maximum temperature again some correction is needed and nowadays we can
get del T also differential thermometer is also available.
And in this case the heat which we get during the heat which is released here it is transmitted
to the water and by del T change we calculate the heat taken up by this.
But which heat is taken up by this water and the bomb material that is not exactly
produced during the combustion reactions only it has some contribution which are not from
this combustion of this but from other sources also.
What are those sources?
One is this crucible which we are using that will also be burnt and it will also release
some amount of energy.
Number one if there is any sulphur the shocks will be produced.
So that shocks again inside this bomb and the water is will be condensed the vapour
will be condensed so that will give up sulphuric acid production.
So that will also add some amount of heat to the total heat which will be taken up by
the water and acids some nitrogen nitric acid can be formed and that some amount of heat
is also generated due to the formations of this acid.
And we need to correct this contribution to calculate the exact heating value of the material.
So if we see that C1, C2, C3 another parameter we will get.
What are those parameters?
C1 is the milliliters of standard alkali solutions used in acid titration.
So to determine the value or contribution of the heat generated during acid titration
during acid formation for that after completions of this bomb calorimeter test we will be open
the lid and then we will depressurize it and then we will open the lid and then take the
material out and then this bomb calorimeter wall will be washed and then that washed will
be containing the acids which was deposited on the wall and that will be titrated against
the alkali solution.
So that what is the ml of a milliliters of standard alkali solution used for acid titration
that we can generate through the experiment and C2 is the percentage of sulphur in the
sample we can determine and C3 in the centimeter of fused wire consumed in firing.
So before starting what is the length of fused wire we are using and after experiment
what is the length of the fused wire unburned so that difference will the burned or used
so heat has been released from that.
So that heat we have to consider for error correction and m is the mass of the sample
in grams how much amount of material we are using that we can also calculate.
So this data will be able to generate now if you see after the combustion heat is generated
H1 and this is taken up by the water and the bomb material so this is water and bomb material.
So if we have M mass of water Mw Sw delT M1 S1 T1 Ms delT so heat taken up by this
water plus M bomb material and S bomb material and delT.
So this is a heat taken up H2 H3 taken up by this two that is water and the bomb material
so that we can get total heat taken up that is equal to delT is common and Mw into Sw
plus Mb into Sb.
So for a particular bomb calorimeter these material are fixed their material of construction
their size are fixed and this bomb is also fixed their volume are also fixed.
So these two terms are constant so that is nothing but W that is called that water equivalent.
So this is the heat taken up and what is the heat released by this material we have M gram
of material so M into H that is the heating value so M into H that is the heating value
that is high heating value that is equal to this delT into W but as we mentioned that
this is not exactly the amount of heat which was generated during the combustion it also
adds something.
So we have to subtract those because of this your E1 error correction E2 E3 E1 is from
the due to the C1 E2 is due to the C2 and E3 is due to the C3.
So then this correction by doing this correction we can calculate the actual heat which was
generated during the combustion so high heating value H will be delT W minus E1 minus E2 minus
E3 divided by M when M is the mass of the material taken in a bomb calorimeter.
So this is the process we follow and by using this formula we can calculate the heating
value.
Now the W how can we get the value of W, W value can be measured using the same calorimeter
and using a known substance now this substance will be known.
So we know the heating value of this substance so that is the standardization or the sorry
so this is the calibration of the equipment we can say.
So in this we used a known material and combust it and in that case we know how much delH
is there how much heating value is there.
So we will be putting this formula we will be calculating E1 E2 E3 M we know so in that
case we will be getting the value of delT into W.
So we can also get the value of W like HM plus E1 plus E2 plus E3 divided by delT.
So that way also we can calculate the value of W and this is done prior to the applications
of the Bohm calorimeter and performing the same experiment using a known compound whose
heating value is known to us like say benzene is used.
So how we will do then how we will calculate the gross heating value then this formula
just we have discussed and how we will calculate the E1 E2 E3 that we have to know.
So E1 is the correction in calories for heat of formations of nitric acid just we have
mentioned that is equal to C1 calories if C1 is the milliliter of n by 10 NOE solution
then this C1 will be here as E1 in calorie unit and if E2 is equal to 13.7 into C2 into
M where C2 is the sulphur content in the material and M is the mass of the material we have
taken for the test and we multiply it with 13.7.
So that calories will be our E2 and E3 will be depending on the type of materials which
we have used for fusing purpose or fuse wire material.
So like if it is a power 45 C1 10 nickel chromium then that will be 2.3 into C3 where C3 is
the length of the fuse wire which was combusted during this process in centimeter unit and
this equal to 2.7 into C3 where the 34 B and S gauge iron fuse wire is used and this equal
to 0 and 34 gauge or finer platinum wire is used.
So this values will be provided by the supplier of the bomb calorimeter.
So now knowing all those things we can calculate the Ag values knowing the value of W. So W
can be determined by standardizing the calorimeter using a compound whose heat of combustion
is known basically benzene is used.
So this is the standardization procedure we have mentioned.
So that is W is the energy equivalent of the calorimeter in calories per degree Celsius.
So these are the different methods we have already discussed.
Basically 0.9 or 1.2 within this the benzoic acid is used for the determination of W value.
Now let us see in our problem statement what are the values.
So as per our problem statement we know that high heating value will be T into W minus
C1 minus C2 minus C3 by M and in this case the M is equal to 1.5 gram it is given and
C1 that is 2.5 ml standard alkali is required and C2 2 percent sulphur and C3 is equal to
4 centimeter of wire the fuse wire and T is equal to 28 minus 23 that is equal to 5 degree.
So that is equal to del T basically and W equal to 2402 calorie per degree centigrade
it is given in the statement.
So E1 will be how much it will be related to C1.
So this equal to 2.5 ml into 1 calorie per ml.
So 2.5 calorie then E2 will be 13.7 into C2 into M calories that is equal to 41.1 calorie
and E3 2.3 into C3 that is equal to 9.2 calorie because the fuse wire which is used that has
this formula and then what will be the Hg that is equal to Tw that is mean 5 into 2402
minus 2.5 minus 40.1 41.1 minus 9.2 and divided by M that is equal to 1.5.
So we are getting 7971 calorie per gram 7971 calorie per gram.
So this is our we are getting gross calorific value or high calorific value.
So net or low calorific value Hn will be having by some empirical relationship we have
discussed in the previous class.
So that is 0.555927 into 1.8 Hg minus 91.23 into H where this Hg is the gross heating
value and H is the percentage of hydrogen.
So in our previous statement percentage of hydrogen is given.
So we will multiply this.
So we will use this formula and keeping these values of Hg that is equal to 7971 and value
of H as 8% it is already given.
So we by this calculation we are getting 7570.59 kilocalorie per kg.
So now the problem is solved and then problem number 6.
So the statement is to determine the water equivalent of a bomb calorimeter 1.1651 gram
benzoic acid sample heating value 6318 calorie per gram was used.
The experiment produced a net corrected temperature rise of 3.077 degree centigrade.
The acid titration required 11.9 ml standard alkali and 8 centimeter of PAR 45 C10 nickel
chromium fuse wire was consumed in the firing.
Determine the water equivalent of the bomb calorimeter.
So just discussed.
So water equivalent we can calculate by this formula H into M plus E1 plus E2 plus E3 divided
by T. Now in this case H is given, M is given, C1 is given, C2, C2 is very important because
we are taking pure benzene.
So we are using benzoic acid.
So benzoic acid does not have any sulphur.
So sulphur content is equal to 0 or C2 equal to 0.
So E2 will also be 0 and C3 is 8 centimeter as it is given.
So T equal to or del T equal to 3.077 degree centigrade.
So by putting this value E2 is becoming 0 and E1 is certainly 11.9 into 1 that is equal
to 11.9 calorie and E3 is equal to 2.3 into C3, 2.3 into 8 equal to 18.4 calorie.
So W equal to HM that is 6318 into 1.1651 plus E1 that is 11.9 plus E2 equal to 0 and
E3 is equal to 18.4 and divided by the temperature, right, so that is 3.077.
So we are getting 2402.1 calorie per degree centigrade.
So that is the energy equivalent of the bomb calorimeter.
So now we have solved all the problems up to this in this class.
Thank you very much for your patience.