Replacing a reciprocating compressor that was over amping.

HVAC GUY
37 followers
Tools I Use In My Videos 👇👇👇
https://www.amazon.com/shop/hvacguy
I was out here about a week ago, and diagnosed a compressor that was way over amping. This is my return to replace compressor. #hvac #hvaclife #fieldpiece #copeland
AI Generated·May contain errors
We are back on this one
to do this compressor.
Right now I'm trying
to get this pincer all out
of here.
There's my crankcase heater.
Got the plug pulled out.
Actually
that and this are an exact
match. I did notice that I got what
looks like five eights right here
and that's a three-quarter
that's three-quarter on the compressor
so i'm gonna put me a piece of three-quarter and
slide the five-eighths
in on that one everybody else is going to voicemail
even
though
you
recover
all
the
freon
don't
mean
you
ain't
gonna
beat
some
of
that
posture
back
in i
think
i am
gonna
cut
that
right
there's
a
good
reason
why i
couldn't
get on
that
screw
holding
the
compressor
in
because
there
wasn't
one
there
extinguisher
that i
use you
need to
check
and make sure the needle's in the green i had one
on a job that's never been used i pulled it out
my van to keep it beside me
and it was completely empty like i said never been used so you gotta
check
them like
i said i'm
gonna cut
that half
inch
the other
half inch
and get me
a little
piece
of
three
eighths
deburred
it a
little
bit i
don't
always
use
this
but
this
is a
flame
resistant
heat
shield
that
i
put
underneath
if
i'm
afraid
i'm
going
to
start
a
fire
torch
around
to
the
bottom
to look
at it
and see
if i
got it
anyway
i can
put me a
suction
filter
right
here
all of
these uh suction filters
are directional you can
see right here it says
on the other side it has nothing
the end is a directional flow
of the refrigerant
the compressor on these
there's no Schrader in
it when you get it but you gotta make an effort
to make sure that you're able to put a Schrader in
because if you don't give yourself
enough room it ain't easy like I said
this comes from my reversing
valve that is true suction through my accumulator
and right to my compressor so in is on this side
and this
side is
out out
always
goes
towards
the
compressor
it's
gonna
leave
some
burn
marks
but
you
got
to
ease
in
leaving
the
plastic
realizing
there
was
no
Schrader
underneath
and
i
was
able
to pull a good vacuum i didn't realize that i had made
a mistake until later and i pulled my vacuum
pressurized
and
then
changed
freon
i
noticed
there
was
hardly
any
freon
in it
but
down
here
this
joint looked like it had oil on it you may have noticed see
that reversing valve wires came undone
so i've got to plug those back up got
my compressor wires hooked up and really we just
got to do
the wire
everything
up and
wait
on the
vacuum
sticking
out and
that's my
defrost
sensor
but it looks like it's been replaced
so we are we are just about done
y'all may have noticed this
on my arm yesterday i was taking trash
to the dumpster with my forklift i was unloading the
forklift and i dang near broke
my wrist that hurt seven amps it
was over 20 amps the other day
nameplate
calls for
four pounds
4.6 inside we
got a piston
to wait 30
minutes to
tentatively
get
here a little frustrating
when you don't have a whole lot of time in one day you don't want to be
working until nine
trying to play
pay close attention
to that superheat
right now it should
be an 8 and 10.
60 degrees
right now.
73 inside.
Guarantee you
we're going
to have some
more 90
degree
days
shortly.
Better
than
it
did
Friday
when
I was
out
here.
That's
done.
I
appreciate
y'all watching and I'll catch you on the next one.