This lecture expands the previous discussion by introducing the Cooper-Jacob method for solving the Theis equation. Cooper and Jacob (1946) simplified the Theis equation for small values of u and large t, leading to a linear relationship between drawdown and the logarithm of time. The method allows for easier calculation of transmissibility T and storativity S from pump test data by plotting drawdown against the log of time and finding the slope. Additionally, the lecture covers recovery tests, which measure how groundwater levels return to normal after pumping ceases, using residual drawdowns to verify transmissibility. The Cooper-Jacob method is particularly useful for small uuu values to minimize errors, and example calculations illustrate its application.
[Music]
[Music]
hello everyone and welcome to the new
discussion which we are going to have on
th equation assumptions and application
this is part two earlier we have
discussed assumptions and some of the
applications of th equation so let's
start with this uh that you know the
Cooper and Jacob after the development
of this th equation in
1946 they developed further or modified
the equations by THS for small values of
r that is the uh radius or distance you
can say and uh the large values of T
that is the time and where U is small
and therefore the series
terms uh in the equation which is given
below becomes neg after the first two
terms so this uh second equation as
written here earlier we have also
discussed this that U = to r² S upon
4 capital T and T So this uh because of
this the draw down can be expressed by
ASM toote that is the middle value and
we can write as s equal to Q upon 4i T
bracket -.
5772 minus log r² s uh by divided by 4
capital T and T so in this way we can
also uh modify the equation now you know
the Cooper and job method they have
Rewritten changing the decimal
logarithmic reduced to S equal to
2.30 Q upon 4i t log
2.25 Capital
TT uh divided by r² S and this becomes
our equation number five in this case
and uh therefore a plot of draw down uh
which is which will have S storativity
in uh here it is given here stor versus
uh uh time versus time can be given and
this would be a straight line so
whichever the value we get H we can fit
over this and this is the fit line the
best fit line you say and these are the
pumping test data which are coming and
uh they should turn up in a straight
line the when we plot these XY plot
between s and t uh so you recall that we
what we said that large value small
values of R and large values of T which
we will see how so now uh whenever we
want to determine the uh you know uh
with the time longer time what would be
the value and other things then this
this graph can be used for to determine
those values because it's a straight
line here the t z is given here which is
39 minutes and uh of course the uh the T
can go for very long time also that was
the purpose of the method given by
Cooper and Jacob now we can project this
line uh in which s would be the zero and
where T becomes equal to T Z in this
figure which is given here on the right
side and therefore we can write that the
0 equal to 2.3 q and divided by 4 Pi t t
is capital here log 2.5t t0 upon r² s
and this will allow us to for the above
to hold true that is log 1 equal to0 so
we can write uh like this the
2.25 uh capital T t0 upon r² s and that
becomes our equal to one so in this way
we we gets a new equation uh which is
equation number six in this uh uh
presentation is s = to 2.25 capital t t
0 upon
r² now the value of
t uh that is transmissibility can we OB
obtained by this graph and noting that t
o t0 equal to 10 then log t t upon t 0
equal to 1 and when we replace S by
Delta s which is shown here Delta s the
change in the storativity where the
Delta s is the draw down difference per
log cycle of T so in this way uh we also
uh get that in information as well now
earlier we have discussed this equation
that is equation number five and this
equation uh then further becomes after
the understanding in the previous Slide
the this equation can be Rewritten and
that becomes our seventh equation and
that transmissibility equal to
2.30 Q upon 4 Pi Delta s so now we are
placing Delta s in that equation and
thus the uh this procedure is the first
to solve uh transmissibility with
equation uh 7 as you can see the output
here is transmissibility and then to
solve s with the equation six so six we
have also dealt where we are solving the
S so uh this method and that is a Cooper
Jacob method uh applicable only for a
small values of U which we have
discussed initially in this discussion a
small value of U and that means the U
should be less than
01 and to avoid any kind of large errors
this this is important here that only
the condition here is that these values
of you should be very small now H and we
we have been h you know doing pumping
test mostly so we are we will be drawing
the water in the previous discussions we
I have also mentioned that the recovery
test are also done that how the draw
down is getting reduced or achieving the
original level uh in the well that is
the water level in the well and that
that will also H give us values which
should match with our pumping test
values though recovery test may take
long time to Value to a note down and
then uh try to understand the entire
scenario so here H as we know that the
after the Buns the pumping uh test is
over pumping we have stopped and then
water level in the pump and the
observation Wells Will begin to rise
will begin to uh achieve the original
level of water before the pumping so
here what we are having on the right
side a figure which is quite nicely
demonstrating this uh recovery test that
this is the first section of in the
x-axis is the pumping period and then
suddenly once the pumping stops then we
are having now the recovery period which
you can see here so second part of the
x-axis is recovery period and what would
happen in the recovery period there will
be change in the water level with the
time and after pumping as this is the
where the pumping has stopped now the
time which is lapsing or going on uh we
will put as a TS and this is the time
small T in this in when pumping is being
done this is the draw down because this
is the water level which you are
measuring on the Y AIS so this is this
becomes our draw down and uh when we
plot a draw and this water level versus
time then this should be a curved line
and uh then P when pumping stops then it
becomes the residual draw down that
means the recovery will start and uh
this will be just opposite of what uh
the draw down in the uh in during the
pumping period so uh this way and we can
also get a lot of information about our
hydraulic characteristics of acur so the
recovery of groundwater levels while
measurements of draw down below the
original static level that is the prior
to pump or original level initial levels
during the recovery period are known as
residual draw Downs so you know there
will be a original level pumping stops
now residual draw Downs so this you can
also observe here that the originally
the water level was here and then now it
is left with this much Gap so that that
is what we are seeing here as residual
dra down as mention also here so it is
always good to measure residual draw
Downs not only the pumping draw downs
but residual draw Downs though we are
calling as draw down but it should it is
not really a draw down but it is
recovery curve or recovery cone so this
residual draw down becomes because of
all this it is always good to measure
because residual down because analysis
of data enables transmissibility to be
calculated in the pumping also be
calculate the transmiss but in during
the recovery Dr round we can also
recovery test it is more appropriate
word is recover during recovery test we
can also get uh the transmissibility
calculations or estimations so this
provides an independent check on pumping
test results because whatever the values
of transmissivity which we estimated
calculated during the pumping test can
be verified can be validated using the
recovery test based uh transmissibility
data so the cost of recovery test is not
much because it is a natural once the
pumping has stopped and so this is there
and therefore it is always advised that
once the pumping has stop the readings
in the water levels and time should
continue so that we can develop this
kind of figure which is shown on the
right side H further the rate of Q to
the well during recovery is assumed
constant and equal to the mean pumping
rate this is the Assumption which we
carry during the recovery test and uh uh
whereas uh pumping rates often
vary when we are withdrawing water water
in the first part of uh this uh figure
where we are withdrawing the water the
pumping rates can vary and are sometimes
difficult to control accurately in the
field so for that purpose also it is
good that recovery test should also be
performed so if a well is pumped for a
known period of time and then stopped
and uh then dra down will shut down the
uh draw down will stop further and the
draw down after uh will be identical in
that nature that if we change it you
know only thing is that uh it is in
opposite direction but it would be
identical in that sense at least in the
theory but it doesn't happen all the
time anyway there will be some residual
Gap or some Gap would be there which
will be ultimately recovered if we give
more time to uh the Acer to reach to the
original water level so if the discharge
had been continued that means pumping
has been continued a hypothetical
recharge well with the same flow are uh
superposed on the discharging well and
at the instance the discharge is shut
down so this can also happen now uh we
can uh come back to our famous th
equation and for the residual draw down
and now we will call these values as d s
Das can be given as that s d equal equal
to Q upon 4 Pi T and bracket w u minus w
u Das and this becomes our equation
8 now where we know that U = to r² S
upon 4i T so we can also write the same
way for Recovery uh test uh u- r² s upon
4i
t- so these are the same equations
except that we are now putting death
because of recovery test so just to
distinguish between the pumping test and
Recovery test so where and the T and T D
are defined in the uh in the earlier
figure which we have seen here so for uh
is small r r is small and T large t d
large because the recovery uh time is
large we will give uh because it is uh
not as like pumping so the well
functions can be approximated by first
uh uh two terms it should have been two
here two terms of equations uh three
which we have uh earlier discussed and
uh which is right uh
s = q upon 4i tet - 5
772 - log e u + u - u² upon 2 L2 and
then u3 and likewise we keep writing
depending on our requirements so
therefore the equation can be reduced
the above equation can be reduced to s-
= to 2.3 earlier also be reduced similar
way but there Des was not there but now
here for Recovery test the same thing so
for Recovery test 2.3 q 4i t log T upon
T Das so now again a plot of residual
draw down s versus s- versus log T upon
T Das forms a straight line as discussed
in the earlier examples also so whenever
the you get the value you can uh get the
and that straight line so the slope of
line H would be equal to
2.3 ID 4 uh uh Mt for the Delta s and
the residual D on per log cycle of the
transmiss becomes H that t = to 2.3 Q
upon 4 Pi Delta s d so this there is no
comparison of values of s can be
determined by this recovery method
now one of the examples of recovery test
is given here that a pumping uh it is
assumed that the CU was was having a
uniform rate and uh though earlier we
said that it is very hard to get uniform
queue or uniform pumping from a well but
let's assume that it is uniform that is
one of the
assumptions and which was the uh uh 2
500 cubic m per day was shut down after
240 minutes and thereafter the
measurement of s d means recovery test
and S D and T Das tabulated which is
shown here in the figure and that t d is
here and also s d is here units are also
given here in an observation well and
determine the
transmissibility what ultimate aim is to
determine the trans transmissibility
during recovery test and compare these
transmissive values with the
transmissibility which was obtained
during the pumping test so uh now
solution to this is that the T upon TD
are computed uh which are also shown
here T and T Das are computed and then T
and T Das versus S Dash plot H is
prepared on semi loock paper so this is
that example here is that we are having
on x axis T and T Das and on Y axis we
are having residual draw down that is s
des and it is shown again it is a
straight line which you can see here so
if I want to find the value anywhere H
with with this best fit line then I get
it also I get the delt s value here so
this is the solution for the uh recovery
test method for solution of non equum
equations so a straight line as you can
see in the right figure is fitted
through points of Delta s and which is
equal to4 is determined then now we can
put in the equation so the equation
which we are going to use as discussed
earlier also and that is T = to 2.3 Q
upon 4 Pi Delta s so uh that would be
become when we substitute these values
accordingly then we we end up with this
that t would be
1140 square m per day so likewise we can
determine the t uh during the recovery
test also using the same equations as we
have been using uh during the pumping
test the only difference here while
writing these equations we are using uh
these values with the desk so that way
uh now the value which we get here can
be compared with the previous uh uh
discussions where the T value would be
almost same as during the recovery test
and this this is that is why it is
recommended that once the pump uh for a
pumping test once the pumping is stopped
the noting down of water level with the
time and should continue for longer time
so that we can also calculate the value
of
transmissivity during the recovery test
and then this value can be compared so
that we can validate that during pumping
test whatever the variations in the uh
output that is whatever the variations
in qway are there H which we are assumed
as uniform constant H but here because
here no energy is required nothing no
pumping is done you left once you stop
the pumping then you left Thea to
recover and to reach through the
original level as also discussed that uh
uh to reach to the uh original level
might be difficult or sometimes
impossible because uh if it is say
premonsoon
situation so where you may not reach to
the top or the original level of water
in the well but anyway that residual uh
thing will remain there or the gap
original draw down curve and that would
be there but nonetheless uh we can
determine the uh T value and then
compare with the pumping test so with
this I end this discussion thank you
very much
[Music]
a
[Music]