Lecture 08: More Aspects of Debye Shielding

IIT Roorkee July 201
61 followers
2 Video Views·Jan 26, 2024
In this lecture, we will try to understand some more aspects of Debye shielding. We derive an expression for the temperature dependency of the electron and ions and try to understand two cases when the electron temperature is much larger than the ion temperature and vice versa. The Debye length depends on the temperature of the colder species.
[Music]
[Music]
hello dear
students in today's lecture we will try
to understand some more aspects of
device shielding and we will try to
answer some
questions related to the assumptions
that we have made in deriving the Divide
potential so if you remember the basic
assumption that we made while obtaining
an expression for the device potential
is that we assumed the number density of
let's say electron to be varying
according to the Maxell distribution
which is E5 by KBT
where five is the potential right and
the charge density that results inside
the divis sphere is basically due to the
difference of number of electrons and
number of
ions
right so this is the charge density
right so number of electrons are larger
within the divice sphere because they
are attracted towards the positive
charge and all of them are are within
this sphere whose radius is Lambda d
right now here while we were doing this
we assumed the number of ions to be
equal to n
infinity and we assumed that the
temperature of the ion was never
considered that means that there is no
distribution of ions as such and that's
why we have canceled this n infinity out
right and we were left with only this e
5 by
KBT
right which also means that electrons
are being heavier they are not moving or
this potential is not influencing the
ions they will constitute a constant
background all this right now we will
take a situation in which number of
electrons and the ions both of them are
distributed according to their
respective temperatures let's say TI and
te and then we will try to find out what
is the expression for Lambda D and how
this expression of Lambda D will be a
function of the temperature of both the
species te and TI and we will look at uh
two different cases in which the number
of ions or if the temperature of ions
becomes very large in comparison to the
temperature of electrons and vice versa
right so this is going to be objective
of today's discussion and then
subsequently we will derive or we will
actually solve a numerical problem and
which will actually conclude the entire
discussion of the device shielding or
device potential and
everything looking back the device
length Lambda D signifies the distance
over which a particular electric field
or charges presence will be made
invisible after the distance and Lambda
D is if you compare Lambda D to the
length scale of the plasma system it
should be very very small in comparison
to this this is probably the second
plasma criteria that we have obtained
and the third one is using Lambda D we
derived a parameter called as ND we call
this parameter as plasma
parameter
plasma
parameter
it tells you how many number of
electrons how many number of charge
species are present within the device
sphere and we have seen that for an
idealized ionized gas to be called as
plasma the number of particles must be
very very large and the first plasma
criteria was Omega P to C should be much
greater than one so put together these
three conditions
are known as plasma criteria and
validity of these conditions is a must
for calling an ionized gas as a plasma
all right now looking back if you
remember one equation that we have
derived we will write that equation and
that equation is the basis of today's
discussion which is d
² x by D r² Square
minus X by Lambda D ² is equal 0 where X
has r f and five is the device potential
right so this equation tells you the
origin of the device length so we will
take this equation and we know what we
did before we reached this equation
right and how we can slightly modify the
picture to draw more meaningful insights
about the plasma potential is today's
objective so let us say
we start from the distribution of uh
charges so in the earlier case we have D
S 5 by D x² now I have made a shift from
R to 5 where X was earlier just a
quantity which is just R5 and R is the
radial distance away from the positive
charge right now I'm calling X as the
position coordinate and five as the five
as the uh potential itself right so D S
5 by DX s can be written as minus E
* n i minus
n divided by
Epsilon you can uh look into the notes
of last class or the class before that
and you will find a similar equation
where earlier we have taken a
possibility that the charge multiplied
by number of electrons minus number of
ions is responsible for giving the
charge density so D S 5 by DX squ is
resulting from the poison equation and
what I've done what the modification
that I've done is that I have not
considered a case where number of
electrons are larger invariably larger
in comparison to number of within the
divice sphere I considered a more
General case Okay in which uh what I'm
going to do is I'll keep minus E by
Epsilon KN as it is and since I'm
allowing the possibility of number of
ions as well as number of electrons to
be distributed according to their own
temperatur so by now you must have
figured out generally in kinetic theory
we refer to temperature as a single
quantity which represents the entire uh
measure of the energy or kinetic energy
that is there within the gas system but
in plasma we consider the electron
temperature and ion temperature so the
temperature is different these two
temperatures represent the kinetic
energy the average kinetic energy of
electron species as well as ion species
because of all the things that we have
understood about plasma so
far these two temperatures have to be
different right so electron the ion
density ni I can be written as n
infinity e to the^ of
minus E5 by KB d i right I'll write it
here yeah so ni I
is n infinity n infinity is the
equilibrium or let's say we consider the
total number of electrons n i sorry ions
n i e to^ of minus
E by KB D this is nothing but e^ of
minus E by KT so this is if you have
studied any uh second or first year
level BSC this may have been introduced
while discussing lasers okay and Ne
similarly NE e is n infinity e to^ of
E5 by
KBT you see The Disappearance of the
negative symbol in in the exponential
was already discussed in the last class
because within that sphere the device
sphere the number of electrons are
extremely large right so that is where
it comes actually right if you
substitute these two things we can write
D
² 5 by D x² equal
to - 1 by
Epsilon to e *
n infinity e to power
of minus E5 by KB
D minus n infinity e to the^ of e by KB
d
e right doing some simplification we can
write it as minus n infinity e
divided by Epsilon
not taking only
the relevant terms when you expand the
exponential in the tailor series we can
write it as 1
minus E5 by
KB di
minus 1
+ E5 by
KB
T which will
be minus n infinity e by
Epsilon * 1
- E5 by KB
TI min-1
minus E5
by KB
D so this will get cancelled
and what we have is this will be
approximately equal to n infinity e by
Epsilon
minus minus E5
by KB D minus E5
by
KB
D so effectively we can write we can
take this minus outside and all of the
right hand side will become positive
then we can
write n infinity
e by Epsilon
times E5 by KB D
i+ E5 by
KB
D or n infinity e s / Epsilon time * 1
by D + 1 by D * 5 what do we have on the
left hand side we have D
² 5
by DX
s if we write all of the terms on the
left hand side you'll get D ² 5 by DX s
minus n infinity e s / Epsilon time 1 by
t i + 1 by T * 5 is equal 0 let us
compare this equation with what we had
when we considered the electrons only to
be distributed according to their
temperature and ions to be constituting
a constant background okay what was that
equation This One b² X by d r² - x by
Lambda d s is equal 0 so which is d s
5 by Dr r² minus X by okay if I'm
writing everything in terms of
X then I should write X
here x
by Lambda d s equal to Z right so now
comparing these two equations what I can
write
is 1 by Lambda d
s is n infinity e s n infinity e s divid
by Epsilon into 1 by D + 1 by
T right so Lambda d s now has some terms
relevant to the temperature of ion as
well
earlier Lambda d
is square root of I think we missed one
KB in between right so KB yeah KB is
here the busman's
constant
okay did we write it here
yeah now it should KB should appear
here right Lambda D is equals
to earlier Epsilon KB T /
n² so in this we thought Lambda D is
proportional to temperature and Lambda D
is inversely proportional to the number
density which means at larger
temperatures when you have more energy
available to the electrons they will
move more
fast and they will not be able to be
restricted within a small value of
Lambda D because of the larger velocity
you have to accommodate a provision in
which the the larger Lambda D takes
place to nullify the positive test
charge so the proportionality can easily
be explained in terms of in terms of
physical perception and it is
proportional to 1 by n that means more
is the number of particles per unit
volume smaller or will be the device
length that means if there are more
number of electrons within a small
volume then
obviously uh the concent of electrons
that you would need to nullify the
positive charge are available within a
smaller distance that means Lambda D
will be small right so both of these
things are very very well acceptable in
terms of easier uh applying simple
common sense right how the how the
expression has changed is is this right
so let us say this is an important
result we will highlight this result
just so that it'll be easy for you when
you look at this lecture notes
right now comes the most important
conclusion of this discussion what is it
we can have a situation in which the
electron temperature is very large we
can have a situation say one is the
electron temperature very very large in
comparison to the ion
temperature we can have another
situation in which the exactly opposite
it may be a possibility the ion
temperature is very very large in
comparison to electron temperature so
what will happen in that case this is
the most important conclusion that we
are going to draw so let us take this
expression as it is 1 by Lambda D ² is
equal to 1 by Lambda D ² is equal
to Y Infinity e s by Epsilon KB time
1 By Di + 1 by
D let us take a situation in
which the electron temperature is very
very large in comparison to ion
temperature so without actually uh
expanding this term without actually
doing this summation we can stri forward
say that if the electron temperature is
very very large this term becomes very
very small so we can neglect it alog
together and we can write 1 by Lambda D
² is equal to Y Infinity e s / Epsilon
KB into 1 by D or Lambda d
s is
Epsilon KB
TI by n infinity b² we can write it as
the device length is under
root Epsilon
KB di /
by n infinity e s we can arrive at the
same result saying that let's say this
is the T T and TI + T when electron
temperature is very large we can write
it as
t ided t TI this will get cancell you
will be left with di that's what we have
right that means
when electron temperature is larger the
device length is decided by the ion
temperature right is it what we are
seeing now right so that means the the
device length we will write it
here device length
will
depend
on the on the temperature
of Colder
species isn't it this is a remarkable
result
actually and exactly when you do it for
the case of ion temperature becoming
very very large in comparison to the
electron temperature
the expression will reduce to something
like this 1 by Lambda d s is n infinity
e s by Epsilon KB * 1 by t e I hope you
can figure out the algebra by yourself
it's not complicated after all yeah 1 by
Lambda d s becomes n infinity e s
Epsilon KB into 1 by TI which means now
the temperature that appears
in this expression is not the higher
temperature rather it is the lower
temperature right so we can write Lambda
D is equals to
Epsilon
KB T
/ n infinity e
s under root right now you see these two
expressions which
are telling a simple fact that under a
situation let's say if you don't assume
that the number of ions or the
distribution of ions is independent of
the ion temperature then your expression
for the device
length is not the same it will be
decided by the colder temperature or the
temperature of the species which is
colder right so that's why we have these
two expressions Lambda D is equals to uh
as a function of TI when electron
temperature is large and Lambda d as a
function of te when the ion temperature
is large so I'll write the conclusion
here so the conclusion
is device
length
will depend
on the temp on the temperature
of
Colder species
okay right
so now we can discuss a
numerical based on what we have
understood and then probably this will
even uh help us to
visualize the nulling or shielding of
the unit positive test charge now having
seen this uh the effect
of temperature on the distribution of
ions and electrons and how it modifies
the definition of Lambda D we will take
up some examples numerical examples or
problems based on the derivations itself
to clarify these Concepts and to make a
more concrete understanding of the
device
shielding
[Music]