Lecture 29

IIT Roorkee July 201
61 followers
1 Video View·Dec 3, 2023
This lecture covers the details regarding the boiler water, water carryover, treatment approaches, and details regarding the safety valve selection for boilers.
[Music]
so
[Music]
welcome to the next segment of esteem
and accessories and if you recall that
previously we were discussing about the
concept of economizer we had a
discussion about the super heaters apart
from this
we discussed about the various other
essential
accessories and mountings attributed to
the boiler including the pressure cage
including the tds sensors including the
temperature gaze and glass
viewing system etcetera in this
particular
lecture we are going to discuss the
the
essentials for attributed to the
water
quality of a steam concept of water
carry over external water treatment
we will discuss in detail about the
safety wall and how we can select the
appropriate safety wall for the boiler
in question
we will discuss about the other safety
devices including the seating and other
shear pinning system
we will discuss the concept of
condensate recovery discussed about
the importance of condensate
in the previous lectures we will discuss
about that how we can recover and what
are the essential for the condensate to
recovery system
so let us start with the water for the
boiler the operating objective for steam
boiler plant this includes
must have a safe operation
they must have a maximum combustion
output and heat transfer efficiency
also they should offer a minimum
maintenance
and it should have a long working life
these are the some of the other
essential aspect of a boiler
now see we discussed that the quality of
the water used to produce
the steam in the boiler this have a
profound effect on meeting the objective
of the boiler
there is a need for boiler to operate
under the various criteria now these
criteria includes that it must have a
freedom from scale
and freedom from corrosion and chemical
attack
you see that in the previous lectures we
discussed about the concept of scale how
these scales are generated and how
dangerous these skills are and how they
are non efficient similarly apart from
this scale the corrosion and chemical
attack all these are also very important
because some of the debris carry may
carry the metal part and if you are
using these steam steam directly to any
chemical reaction it may create a
catalytic effect so all these things are
extremely you can say
important
so for good quality of steam the
impurities in the boiler feed water they
are not deal properly if you are not
dealing them properly then the carryover
of a boiler that means the contamination
of the steam with boiler water boiler
water solids
into the steam system can occur and this
may lead to problem elsewhere in the
steam system as i discussed that if you
are directly introducing to steam this
esteem into any chemical reaction
even
the small small metal particles may
participate in the reaction so ah the
removal of all such kind of things is
quite essential
they may contaminate to the surface of
the control walls
ah maybe by the deposition may be by the
corrosion erosion etcetera so this will
affect their operation and reduce
their capacity
now the contamination of the heat
transfer surface
of the process plant this will increase
the thermal resistance
and reduce the effectiveness of heat
transfer and that is quite essential for
the the
maximization of efficiency concept
ah sometimes they may restrict the
esteem trap orifice and again it may
create a problem because if steam trap
is not working properly then it will not
sense
the or it cannot distinguish between the
steam and the water and that will be
extremely dangerous for the boiler
operation or the steam is distribution
network
so
if there is a restriction in the steam
trap orifice this will reduce the steam
trap capacity and ultimately lead to the
water logging of the plant and reduce
the output
let us talk about the over now this
carry over can be caused by two factors
one is the priming this is the ejection
of boiler water into the steam takeoff
and is generally due to one may be
one or more of reasons attributed to
this one operating the boiler with the
too high water level
so again it is very dangerous because
you are imparting excess amount of
energy to produce the steam operating
the boiler below the design pressure
this increases the volume and velocity
of the steam released from the water
surface and sometimes it may be because
of the excessive steam demand
ah second aspect is the foaming
this is the formation of foam
in the space between the water surface
and the steam takeoff
now the greater the amount of foaming
the greater the problem which can be
experienced now there are certain
indications and consequences of foaming
ah one is that water will trickle down
from the steam connection
ah of the gauge glass and this makes it
difficult to accurately determine the
water level so it is just like this that
this is your gauge glass
and if foam is deposited over here in
that case it will be quite difficult for
a person who is visualizing the
the water level and
or sensing the the the water level
through the sensor in that case it will
be quite difficult for them to sense the
accurate water level and in that case
the results may be extremely dangerous
another thing is that the level probes
floats and differential pressure cells
they have the difficulty in accurately
determining the water level
ah now in case if any this such type of
problem alarms may be sounded and the
burners may even lock out
this will require the manual resetting
of the boiler control panel before
supply this can be re-established
now these problems may completely or in
part due to the foaming
in the boiler however if
because foaming
is an endemic to boiler water
now
sometimes
if you are having excessive agitation
within the system
then it also increases the foaming
because of the alteration in the the
surface energy
so again it it causes a problem
another
the cause of foaming is the hardness
usually hard water does not form ah form
however boiler water is deliberately
softened to prove prevent the scale
formation and this gives it
the propensity to form
so you have to be very careful
and if you are imparting any kind of a
chemical dose or providing the dosing
then you have to be very much aware
about all the consequences
sometimes colloidal substances they are
also very important the contamination of
boiler water with the collides in
suspension
ah for example milk this causes violent
foaming
collider particles
those who are less than point zero zero
zero one ah millimeter in diameter and
can pass through a normal filter so all
these
are need to be addressed
ah we have already discussed this tds
concept the tds level as the boiler
water tds increases the steam bubbles
become more stable
and more reluctant to burst and separate
there are certain chemical controls
like
we we may add certain anti-foaming
agents or chemicals these may be added
to the boiler water
now these operates by breaking down the
foam bubbles that means they are the
surface
active agents etcetera ah
however these agents are not effective
when treating form caused by the
suspended solids
so the the
to control the
fatigues a balance has to be found
between the high tedious level
with its
you can say attendant economy of
operation
and a low tds level which minimizes
foaming
sometimes see
we need to have some external water
treatment
protocols
because there are various sources of
water maybe the natural water may be the
surface water maybe the ground water may
be the subsurface water maybe you are
you are taking water from the the river
or a canal or
maybe municipal water
so you cannot
feed this water directly to the boiler
because there are certain inherent
impurities inherent impurities may be
attributed to the hardness may be
attributed to the certain debris may be
attributed to the certain dissolved
solids etcetera
so you need to go for water treatment
process
and this is termed as the external water
treatment so the external water
treatment processes can be listed like
reverse osmosis
lime soda softening iron exchangers
demineralization now these process or
this process
remove virtually if
all the salts
and it involves the passing the raw
material through through the cation and
ion exchange raisins or other chemical
dosings as the case may be or as the
case may required and this all depends
on the impurities
inherent impurities in question
ah so we are not going this to discuss
these
these water treatment protocols because
we will address this thing in a separate
section
now let us talk about the safety walls
in detail
now as you know that
the primary function of a safety valve
is to protect the life and property as i
discussed a previous example of a
domestic pressure cooker is again the
pressure vessel it equipped with the two
different type of safety devices
now the principal type of device
used to prevent the overpressure in
plant is the safety or safety relief
wall
the safety valve operates by releasing a
volume of a fluid from within the plant
when a predetermined maximum pressure is
reached and thereby reducing the excess
pressure in a safe manner
you see that in
when we were discussing about the boiler
the boiler rating there are three
different type of pressure working
pressure bursting pressure hydraulic
pressure so if it
crosses the working pressure limit then
always the safety device is actuated and
the excess pressure can be released in a
safe manner
now pressure excess can be generated in
a number of different situation this may
be
like imbalance of a fluid flow rate
caused by inadvertently closed or opened
isolation valve on a process vessel
failure of ah cooling system which
allows vapor or fluid to expand
compressed air or electrical power
failure to control the instrumentation
there may be certain transient pressure
surges
there may be certain exposure to the
plant fire
heat exchanger tube failure
uncontrollable exothermic reaction or
thermal runaway reaction in the plant
ambient temperature changes
now usually ah when we talk about the
safety devices so a valve which
automatically without the assistance of
any energy other than that the fluid in
question discharges a certified amount
of
fluid so as to prevent a predetermined
safe pressure
being exceeded and which is designed to
reclose and prevent the further flow of
fluid after normal pressure condition of
the service have been restored now these
are the two essentials of safety walls
so when the pressure
is beyond the working pressure then the
safety valve actuated so
this can be
achieved by the variety of ah method but
if the original desirable pressure is
restored then automatically safety valve
should be closed so that the precious
fluid
or pressure as a steam cannot be
go beyond the periphery of the boiler or
the the process in question now this is
the anatomy of safety wall here you see
that this is this the cap and this is
the spring adjuster to meet out
the the any kind of a fluctuation within
the the system
this is the spring
and based on the spring constant or kx
this usually works and this is this is
spring is housed in a system that is
called the bonnet through which a
protective shell can be designed this is
the main body
and this here you see this is the blow
down ring and this is the main thing
that is the disc
and this is the seat so usually the disc
is seated over the seat so when the
pressure mounted or pressure is above
then this based on the spring constant
the spring usually compressed
and the excessive steam can be go out
and when the desired pressure achieved
then it this disc can be reseated to the
the seat and the the flow of the
the fluid can be seized off now here you
see that two different type of
safety walls here you this
you see that this is the spring and here
this is the seat and a disc
and you can adjust the
the things with the spring adjuster
now let us talk about some ah some basic
operation of a safety valve the foremost
operation that is called the lifting now
when the inlet static pressure rises
above the set pressure of the safety
while the disc will begin to lift
off the seat
now as soon as the spring starts to
compress as you we discussed in this
particular figure
figure the spring force will increase
and this means that pressure would have
to continue to rise before any further
lift can occur and for there
to be any significant flow through the
wall
now the additional pressure riser here
you see that is a more closer look this
is the disc and this is the seat now the
additional
pressure rise required before the safety
wall will discharge at the rate its
rated capacity is called the
overpressure
now next is the re-seating because once
you restore the normal operation
condition the valve required to be close
again
but
since the large area of disc is still
exposed to the fluid the wall will not
close until the pressure has dropped
below the original
set pressure so you have to look this
particular equilibrium in between the
disk and the boiler pressure
sometimes people ask about the material
of construction of
these safety walls except when
the safety valve are discharging the
only part that are wetted by the process
fluid
are the inlet tract or nozzle and the
disc
and usually disc and seats they are
direct in touch with the
with the working fluid now since these
safety wall operate infrequently under
normal conditions all other components
can be manufactured from standard
materials for most applications
ah there are however you can say the
several exceptions in which spatial
material have to be used and this
includes sometimes if you you may
require the cryogenic application in
that case the expansion and other things
you need to look into then sometimes you
you are handling the corrosive fluids so
you cannot make your disc or safety
valve
those who are very much reactive with
those fluids now another aspect is that
where the contamination of discharge
fluid is not permitted then you have to
keep some more more
additional attachment to the safety
devices now when the valve is discharges
into the manifold that contains
corrosive media discharged by another
wall
the principal ah pressure containing
component of safety walls are normally
constructed from different metal
materials like bronze they are commonly
used for small screwed wall for general
duty in steam air and hot water
application that may be used up to ah 15
bar then the cast iron usually
they are used in extensively for asme
american society for mechanical
engineering type of
wall they have designed their own codes
and this the use is typically limited to
17 bar gram
then the cast iron and oracasta steel
commonly used on high pressure
walls up to 40 bar
process type walls are usually made from
a cast steel
body with an
austenitic
full nozzle type construction
the selection of now question arises
that how we can have because we are
having a large sized
galaxy of steam safety walls and we are
having a number of choices then question
arises that what should be the guiding
parameter through which we can have an
appropriate safety wall selection the
the selection of a specific type of
safety valve is usually tutored by
several factors one is the cost
and obviously it is one of the key
factor
for consideration so when
selecting a safety valve for non
critical operation it is you can say
most of
most obvious consideration now when
making cost comparison it is imperative
to consider the capacity of the valve as
well as the nominal size another thing
is that the type of disposal system wall
with an open bonnet these can be used on
a steam air or non toxic gas but if
discharge to the atmosphere other than
through the discharge system is
acceptable a lifting lever is often
specified in these type of application
as you see in the figure
then the wall construction a semi nozzle
type construction this should be used
for non-toxic non-corrosive type media
at moderate pressures
whereas evolved with the full nozzle
type construction they are typically
used
in the process industry for corrosive
media or
for extremely high pressure so if we are
using the corrosive fluid
or high temperature special material of
construction this may also be required
another
foremost
criteria for the safety wall selection
is the operating characteristics
performance requirement they may vary
according to application and the wall
must be selected accordingly for steam
boilers a small overpressure is required
usually say three to
four five percent for most of the
replication ten percent over pressure is
required
ah now very important part of safety
wall selection is the approval
so for many
wall application the end user
will state the required code or standard
for the construction and performance of
the wall as you noticed that in the
boiler we are having the different type
of a code and standards based on the
country to country reason to reason
similarly we are having the similar type
of codes and standards for the safety
wall now this is usually accompanied by
the requirement for approval by an
independent authority to guarantee the
conformance
with the
required standard apart from this
there are certain other alternative
plant protection device you see that if
we are comparing the things with our
domestic pressure cooker where we are
having the two different safety devices
one is the safety valve another one is
the safety vent which is sometimes
referred as a whistle
similarly ah in
all the boiler house or steam power
generation plant there are
other alternative plant protection
device and these devices are equipped
with such type of a different things
so ah the thing is that
the safety walls are by far the most
common devices
used for the plant protection in steam
system
there are several other devices
available to protect plant from over
pressure condition
some of them you can use
in place of a safety valve most of them
they have own unique application and
indeed some devices such as bursting
disk
this may be used
to complement the safety valve
ah
another thing is that
weighted pallet
and previously
various boilers
they are using the counterweight safety
walls
now now
these are
largely superseded by the spring loaded
safety valves now here the concept is
common you are having a weights
and this is the steam generation unit or
boiler
now if
and this particular
seating or re-seating arrangement is
usually
complemented or supplemented by these
counterfeits so in case if there is any
ah
excess pressure this lever
may go downward and by this way
the the seat or disc can be open and
excess steam can be discharged to the
atmosphere
now we were talking about the bursting
or a ruptured disc
now this consists of
an elastomeric membrane or thin metal
disc
that will burst
at a set pressure relieving any over
pressure and usually sometimes it also
give an edge towards the high
temperature system if
the melting point of these elastomeric
membrane or disc operating temperature
is more than the melting point of these
elastomeric membranes they may melt down
to release the excessive
pressure as well as the temperature
now they can be used by themselves on
many applications
they are used in conjunction with the
the safety valve it is just like the
domestic pressure cooker now a rupture
disc
this can be installed either on an inlet
or outlet side of
safety wall
here you see that
the fusible plug device or a safety
device just like your domestic pressure
cooker
now here you see the these consist of a
plug with a lower melting point
ah than the maximum operating
temperature of the system that is
protected so basically it is meant for
the temperature protecting ah protection
device
now this is the simple example you can
screw
it
this is the plug body and this is the
fusible alloy sometimes elastomers are
also being used so if
you may experience if you are
experiencing the excessive temperature
then this
fusible alloy or elastomer may melt down
and excessive pressure can be released
like this
sometimes
the breaking or shear pin devices are
also being used
now usually a breaking pin device
is a pressure relief device
actuated by inlet static pressure and
designed to function by the breakage of
a load carrying section of a pin which
supports a pressure
containing member
now the force of overpressure forces the
pin to buckle out and wall to open
ah the wall can then be re-seated after
pressure is removed and a new pin need
to be installed over there
now these devices are usually installed
on a low pressure application and large
gas distribution system
and that is why because some every time
you need to install a new pin
that is why they have a very limited
applications
now um in last we are talking about the
condensate recovery
now usually when we talk about the
condensate recovery or a condensate
just go to
as basic concept that steam is usually
generated for one or two reason one is
to produce
electrical power for example in power
generation plant or co-generation plant
and supply of heat to for heating and
process system we discussed a couple of
things
um these things
in previous lectures
now ah thing is that
how this condensate is
recovered or how this condensate is
formed so usually when you are
extracting the mechanical energy or when
you are extracting the heat energy then
the steam loss is latent heat and it
convert into ah
water
now since
it it has two valuable things
in it one is
the heat
because obviously when you are
condensing the steam ah obviously it
will have the same temperature the
condensate will have the same
temperature as of steam and second thing
is the water value
because we discussed that
whenever you are using the water in the
boiler
then obviously you need to perform some
water treatment or water conditioning it
always cause the value so you cannot
discharge that particular condensate as
such to the
atmosphere so based on this thing every
steam distribution network is usually
equipped with the condensate recovery
lines
now how we can quantify this
condensate recovery so when a kilogram
of steam condenses completely a kilogram
of condensate is formed at the same
temperature and pressure
so usually an efficient system system
will reuse all these condensate failure
to reclaim and reuse condensate make a
no financial technical or environmental
sense you see one kilogram of steam
condensate and you must have a one
kilogram of
condensate
so if you are giving up i mean after
giving up its latent heat to the process
the steam turns into the water and
containing only sensible heat this is
the usual thermodynamic phenomena
now an efficient
steam system will collect this
condensate
ah and either return it to a deaerator
obviously we discussed about the concept
of data to remove any entrapped air
because air does not carry any any heat
value and a boiler feed tank or use it
in another process feed tank means
you can use this particular condensate
at higher temperature
to maintain the the water level as well
as to pre-heat the system also
now only when there is a real risk of a
contamination
should condensate condensate not to be
returned to the boiler maybe some
contamination through the corrosive
chemicals or maybe some other
contaminants in that case it needs to be
sent for for efficient treatment plant
now when we talk about the condensate
return and effective condensate recovery
system usually
collects the hot condensate from the
steam using the equipment and return it
to the boiler feed system and can pay
itself for a remarkably short period of
time because the heat value as well as
the
the the water value always
very you can say the attractive things
in the condensate recovery
a simple steam and condensate circuit
with the condensate returning to the
boiler tank must be properly designed
and you can see here it is a very simple
diagram
for steam and condensate recovery you
see here we are producing the steam and
this steam is being utilized to the
various open pen or fan vessel for
heating purpose and the processes team
now here you see
that these are the condensate recovery
lines
and these condensate recovery lines they
are connected to the different type of a
system and it is usually returned to
the feed tank so by this way is it is a
simplified
way for representing the condensate
recovery line now question arises why
return condensate and
reuse it
i told you that this may be because of
the financial reason because
every drop usually cost because you are
demineralizing deionizing the things
then water charges because sometimes you
are taking water either from the
municipal corporation or a ground water
or from river or canal or there are a
number of sources of water where from
where you can get it but ultimately the
pumping cost and other cost they are
also
quite high so
water charges are again there so you
need to have a proper water balance to
minimize these
losses
now another aspect is the effluent
restriction that is attributed to the
temperature restriction efficient
because you see that we discussed that
when condensate form so usually it
it is this at the same temperature
which the steam has
so it cannot discharge
this efficient this water to the
atmosphere because of high temperature
then ah obviously when it carries
the the good quality of water
applicable to boiler it carries the
the good quantum of
heat
because of
the steam system
you can
maximize the boiler output as well as
the boiler feed water quality
when you return these condensate to the
the system
so by this way we are summing up this
particular
lecture and we here we discussed the
various aspects of a condensate we
discussed about
the safety wall anatomy of safety valve
and if you wish to have further studies
we have enlisted
ah
three four different references for your
convenience you can go through all these
references thank you very much
[Music]
you