EC365 BIOMEDICAL ENGINEERING || LECT 5 || Electrode Theory ||Bio Potential Electrodes
This video lecture contains
1.
2. Nernst Relation
3. Equivalent circuit for bio-potential electrode
4. Polarizable and Non-Polarizable Electrodes
5.Bio Potential Electrodes
a. Micro Electrodes
b. Skin surface electrode
c.Needle electrode
#ktu #ktunotes #ktustudents
Hi students, today we are discussing about electrode theory, Nernst relation and biopotential electrodes.
In the last class, we learned about bioelectric potential.
So, what do we need to measure this bioelectric potential?
We need a transducer to produce the corresponding electrical signals.
So, what do we do here?
We produce the electrical signals.
We produce the electrical signals of the various activities of the body and monitor them.
In ECG and EEG, we do everything in the same way.
That is, we produce the electrical signals of the heart and monitor it.
To record and measure the potentials of the body, we have to require an interface.
We need an interface to measure the body and electronic apparatus.
The biopotential electrode performs that function.
It records the body's measurement and sends it to the recording instrument.
The biopotential electrodes work as an interface.
What is a transducer?
A transducer has two electrodes.
We use a transducer to find the potential difference between the two points.
We have heard about ECG electrocardiogram and electrocardiograph.
Let us see what is a gram and what is a graph.
A gram is a biopotential waveform.
The instrument we use to measure the biopotential is called a graph.
Electrocardiograph is the instrument.
Electrocardiogram is the waveform we get.
In the last class, we learned about the action potential and resting potential.
Propagation of action potential through different body tissues produces final waveform recorded by electrodes.
Electrocardiograph is the instrument we use to measure the action potential through different body tissues.
What is the difference between body's electrical activity and body's ion concentration?
Electrical activity is explained by the differences in ion concentration within the body.
Sodium, Chlorine, Potassium and Chlorine ions.
A potential difference occurs between two points with a different ion concentration.
Propagation of action potential through different body tissues produces final waveform recorded by electrodes.
Nernst relation is the relative activity of permeable ions in a membrane.
An electric potential E will exist between the solutions on either side of the membrane based on the relative activity of permeable ions in each of these solutions.
Nernst relation is the relative activity of permeable ions in each of the solutions on either side of the membrane based on the relative activity of permeable ions in each of the solutions.
What is Nernst potential?
When no electric current flows between electrode and solution of its ions or across ion-permeable membrane, the potential observed should be half cell potential or Nernst potential.
E is equal to minus RT divided by nF ln C1F1 divided by C2F2.
Rdcd is the impedance associated with the electrode-electrolyte interface and polarization at this interface.
Rs is the series resistance of the electrode material.
Half cell potential is represented by the symbol EHC.
This is the equivalent circuit of a biopotential electrode.
Polarizable and non-polarizable electrodes are categorized into two categories.
No charge carrier across the electrolyte interface when a current is applied.
This is what we call a polarizable electrode.
This is represented by a capacitor symbol.
Non-polarizable electrode is when a current passes freely across the electrode-electrolyte interface.
This is what we call a polarizable electrode.
This is the equivalent circuit diagram for a biopotential with two electrodes.
Let us see what a biopotential electrode is.
A biopotential electrode is a transducer.
Transducers convert ionic condensation into electronic condensation.
This is how we generate biopotential signals.
There are three types of electrodes.
Microelectrode, Surface electrode, Needle electrode.
Microelectrode is used for identifying bioelectric potential near or within a cell.
Skin surface electrode is used for measuring ECG, EEG, EMG.
Needle electrode is used for penetrating skin to record EEG.
There are three types of electrodes.
Microelectrode, Skin surface electrode, Needle electrode.
Let us see what microelectrode is.
Microelectrode is used to measure potential across the cell membrane.
Tip diameter is 0.05 to 10 micrometer.
It is formed from solid metal needles or metal contained with or on surface of a glass needle.
A glass micropipette having lumen filled with an electrolyte solution.
Microelectrode is used to measure potential across the cell membrane.
Let us see what metal electrodes are.
Metal electrodes are formed from fine needles of a strong metal.
Metal is made from stainless steel, platinum, iridium, alloy, tungsten or compound of tungsten carbide.
Insulation is provided for the tip of the needle.
Electrolytic etching method is used to form the electrode.
Electrochemical cell is used to form the electrode.
Metal needle is used as anode.
Electrochemical cell is used as anode.
Let us see micropipette electrodes.
Micropipette electrodes are prepared from glass capillaries.
The desired size is 1 micrometer.
Central portion of the capillary is heated.
A pipette structure is formed.
A lead wire metal electrode is formed.
A pipette structure is sealed with a capillary.
Electrolyte is filled with potassium chloride.
This is a micropipette electrode.
We have seen microelectrodes.
Let us see surface electrodes.
Surface electrodes are placed on the surface of the skin.
There are four types.
Immersion electrode, suction type electrode, metal plate electrode, floating electrode etc.
Let us see four types of surface electrodes.
The first one is immersion electrode.
We used to use immersion electrode.
We used saline water in a bucket.
This immersion electrode improved and formed a plate electrode.
Another old type electrode is suction type electrode.
This is a suction type electrode.
Adhesives are not used in suction type electrode.
This electrode is used in pre-cordial lead or chest lead.
Hollow metallic cylindrical electrode is used in suction type electrode.
A lead wire is attached to the metallic cylindrical electrode.
A rubber bulb is fixed at the base of the electrode.
Electrolyte gel is placed on the surface of the electrode.
A bulb is placed at the base of the electrode.
A bulb is released.
Electrolyte gel is placed at the base of the electrode.
The suction type electrode is used for irritation.
The contacting area is small.
Next is metal plate electrode.
Historically, one of the most frequently used form of biopotential sensing electrode is metal plate electrode.
We usually use metal plate electrode.
A metallic conductor is attached to the metal plate electrode.
A metal plate electrode is attached to the metal plate electrode.
Next is floating electrode.
A conductive paste is used to reduce the slippage of the electrode.
Electrode is filled with electrolyte gel.
Then attached to the skin surface by means of double sided adhesive tapering.
Electrode is filled with electrolyte gel.
Then attached to the skin surface by means of double sided adhesive tapering.
Electrode is a metal disc made of silver coated with silver chloride.
Next is needle electrode.
There are two types of needle electrode.
Unipolar electrode and bipolar electrode.
Unipolar electrode is a single wire inside the needle.
If there is a single wire inside the needle, it is called unipolar electrode.
If there are two wires inside the needle, it is called bipolar electrode.
Next is coaxial electrode.
Coaxial electrode is used to make contact with internal body tissues.
There are many types of needle electrode.
Insulated needle electrode, coaxial needle electrode, bipolar coaxial needle electrode, coiled fine needle electrode, etc.
Next is coaxial needle electrode.
What is coaxial needle electrode?
A shielded percutaneous electrode consists of small gauge hypodermic needle that has been modified by running an insulated fine wire down to the center of its lumen and filling the remainder of the lumen with an insulating material such as resin.
This is a shielded percutaneous electrode.
A shielded percutaneous electrode consists of small gauge hypodermic needle that has been modified by running an insulated fine wire down to the center of its lumen and filling the remainder of the lumen with an insulating material such as resin.
These are all about coaxial needle electrode.