Welcome to Part 3 of the Control Panel Design series, where we take an industrial electrical control panel from a complete bill of materials and layout to some simple PLC & IO schematics, power distribution, and networking drawings, in a practical step by step example.
If you want to follow along with this example, all LeMaster Tech Subscribers can receive a free 6-month trial by emailing [email protected] or message them at https://www.cofaso.com/en/contact with code 'LeMasterTech6'
In this video we do a combination of walking through creating schematics and reviewing simple examples in cofaso electrical CAD software together, and reviewing some great examples from a terrific article by SolisPLC: https://www.solisplc.com/tutorials/electrical-panel-wiring-diagram
Be sure to leave a like on the video and subscribe for more great content! Let me know with any questions in the description of this video, and consider checking out my patreon if you'd like to become a super supporter of the channel! https://patreon.com/lemastertech
Hello and welcome back to the Master Tech
In today's video we're going to be continuing
our series on the basics of electrical panel schematics
and today we're going to take the
layout that we looked at in past videos
and we're going to create some basic power distribution,
PLC and I/O, and networking drawings
so that you get familiar with the three
most common types of individual schematics
that you would see in a drawing package.
A couple quick disclaimers about this episode.
As I kind of mentioned in the layout episode,
there are two major dueling electrical panel standards,
and IEC is the most common international standard,
but NFPA is the most common North American drawing standard.
It would be an extremely long tutorial to try
to cover both of those in depth in this video,
so we will discuss some of the largest differences between the two.
But to keep the video moving,
I'm essentially going to try to focus on IEC because that has
the broadest international reach
and will probably be the most useful internationally.
But I will try to call out some of the key differences
and reference how NFPA works as well.
Okay, to get started, we're going
to be doing two main things in this video.
We're going to be clicking through Cofaso,
which I have explained in this series so far,
is an electrical CAD software
that you can get a six-month free trial for
by emailing cofaso at cofaso.com and mention code lemastertech6.
They will send you a six-month free trial license
so you can learn this as well.
And it doesn't matter if you're at a workplace that uses Eplan
or AutoCAD or any other electrical
standard because we
are talking about broadly how electrical schematics work.
So we'll be clicking around at examples in Cofaso,
but then we'll also be referencing
a great online page with some guidance
for what we're talking about today from a company
called Solus PLC.
This is a great quick reference web page,
so I will also link this in the description
of the YouTube video.
So you too can bookmark this page as a quick reference guide
if you're doing a lot of electrical
schematics.
One of the main reasons I want to also use
that other source is because I am a controls
and automation engineer, I am not a professional CAD draftsman,
so while I'm pretty good at
reading electrical schematics and understanding and interpreting them,
I actually don't generate
a lot of drawings from scratch,
so I've made some basic examples so that we can walk through
through how to do that together.
But I also want to reference a professional source of information
so you can go learn more.
Especially because I'm just one guy
and I'm human and likely to make mistakes,
so the pages you'll see today might even have things
that are a little bit incorrect
as I just teach you about high level standards.
The goal of this video is introduce you to these concepts,
not complete way for you to go from no
experience to CAD draftsman expert.
So with no further caveats, let's just dive into the content
today and start by taking a look at how power distribution works.
That's going to be the first
major type of drawing we look at together.
Okay, so to talk about power distribution,
if you remember from our layout, or even if you don't, this is a small
Simple, minimal PLC plus IO card cabinet where everything,
the switch, the PLC and the I/O cards are going to be 24 volts DC,
but the facility is going to be providing 120 volts AC.
So we have one circuit breaker and a 120 to 24 volt power supply.
And power distribution is generally going to be something really close
to the beginning of the electrical schematic package
that you're dealing with. And this is again,
IEC standard so in IEC you have kind of your L1 neutral
and ground power rails coming across
the potential arrows just across the top
and then we have these branches down showing that our
DC power supply is going to consume that.
We have this black box representing our power supply that
has L1 neutral and ground coming
in and there you can see a circuit breaker on the
L1 feed coming in, and then it has the 24 volt
and 0 volt channels going out, and then they go down vertically
to 24 volts and 0 volts to go be used elsewhere in the cabinet.
This is obviously extremely simplistic,
but it's because this entire panel is only using 120 to convert
into 24 volt power and then be used elsewhere in the cabinet.
So to look at a slightly larger, maybe more typical high
voltage example in something that has, for example,
a bunch of motor contactors and is represented in NFPA standard.
Here you see three phase main power panel coming in,
and this symbol here is a main disconnect.
So this is sort of showing three different phases,
but all connected by one physical disconnect so that you can kill
an entire high voltage cabinet from one main disconnect.
Then you see each main branch that has a driver and a local disconnect
also has a fused disconnect on the power distribution.
So this is an example of a higher voltage power distribution
and it's an NFPA standard instead
of IEC. But if we were to look at what
a transformer might look like in IEC standards,
here on the same page you can see UVW
which is a very normal three-phase convention.
Coming in in this example again going through
main breaker we're taking two of those phases
and we're transforming from 575 volts in this example down to 115.
So this is an IEC example,
but it's the same concept in a slightly more complicated example
of what we looked at in our very basic example.
You take AC in, you transform it to DC,
or even another AC in the case of a transformer out.
Power distribution is super important
because the first thing you
do if you're ever doing live work in a panel is try to
make it safe by either disconnecting
or at least using the appropriate arc flash.
Again, I'm not a great draftsman and I made these relatively quickly,
but also on your main power feed,
you would want to have the overall short circuit current rating
or SCCR listed so that you can properly do your arc flash calculations
so you know what's required to do hot work in that cabinet.
That's another important part of power distribution.
And a lot of problems in electrical troubleshooting stem
from trying to hunt down power issues,
so the power distribution page is one of the most important pages,
and sometimes several pages in
more complicated panels, in the entire package.
Next let's move off of power distribution and
look at a PLC device or an I.O. card, okay?
So now we're on a page that has 24 and 0 volt
as our main potential coming across
because we've stepped down and transformed
From 120 to 24 volts.
And what you'll notice is this is not really
a physical representation of the card, okay?
If you're looking at the layout,
everything is dimensionally accurate
because you're creating a dimensionally accurate layout
of what your page needs to look like.
But this is not the most convenient form
to actually make a drawing off of.
It's generally considered much easier
to have an expanded block
so that the terminals each have more space
and you can add more text and context to your objects.
In the case of an S7-1200 PLC from Siemens,
these often have tons of onboard I.O., so
you can see here we're able to call out every channel
as well as what device is on it, and
we have room for text, a symbol,
and connections to power potentials and things like that.
And that's only possible because of the expanded shape,
so it's not generally considered that
An expanded object in a PLC or I/O card.
Physical dimensionally accurate representation of the object,
the terminals and labels need
to be representative of what you're going to see.
And you can see on this card it has digital inputs,
power distribution, analog inputs,
and relay outputs. And we have the objects showing
that these are all switches and inputs that are
going to be taking 24 volts,
switching or contacting and coming to our input card,
and then our outputs are going to go
to digital output channels off screen somewhere. They're
relay outputs so we don't need additional relays
for these to behave like relay outputs.
Again, this is a very simple example, mainly an IEC format.
And if we go back to our handy dandy cheat sheet,
we can also get a great example of an NFPA standard.
So again, here you see the vertically traversing power potentials.
You can hopefully see an example of a digital input card.
This is an Allen Bradley digital input card,
and it shows 16 inputs all expanded out as well
with the power potential over on the left
and a bunch of contactors and relays on the
On the main horizontal branches, and one thing to call out as well,
since we're here and it's an easy way to make a comparison,
NFPA is generally doing wire labels that are row based because
they take each page and then they generate a set of row numbers.
And those row numbers are going
to generally inform what you label your wires as.
While in IEC, you have a grid that combines
the page number with the column that you find
the objects in for labeling.
So that's just one difference.
You'll usually see these numbers one through whatever at the top,
one through 10 most often.
And then in NFPA, you'll see the column,
the row numbers, sorry, IEC column numbers, NFPA,
Row numbers. So that's just another helpful example.
More maybe just obvious thing to call out about IO modules,
but if we were to make a new page.
You could import a macro again from a OEM,
from a manufacturer, and that way they'll already have
pre-populated for you, but not every card is readily available.
Sometimes it's just time
consuming to hunt those down.
Most likely, if you're doing a lot of this work, your company
already has a deep library of objects and macros.
But you can always just make a block
and grab terminals and just assign the total number
of terminals that your card or device or whatever is going to have.
So the path of least resistance is if you just find
the schematic for a part online,
you can just make a black box,
add the correct terminals and generate the thing yourself.
And then you can save that as a symbol or a reusable part
so that as you're building out more and more schematics,
you don't have to remake cards every time.
Again, macros are slightly different if you're using Eplan
or object blocks in AutoCAD
or just generating your own in different software like Cofaso.
But you can see even in the NFPA standard,
a long vertical block with all the terminals broken out vertically.
Or you look at an IEC version
and you have a long horizontal block with terminals pointing up
and down. It doesn't really matter.
You can generate them yourself. You can use them from
a supplier. The only part that's really important
is that it's clearly labeled. It's clearly
correlated between the physical world what
terminals I'm looking at and what wires I'm
I'm labeling them on the card.
And some of the best and most thorough drawing
packages even go so far as to call out
what color of each wire, what sort of cable they'll go into.
Some distributed I/O cards will
use M12 or M8 connections,
and you can call that out as well depending on the schematic software.
So kind of like I said in the beginning,
it would take probably a one hour long video on its own
to try to cover every iteration of I-O card between IEC and NFPA.
But at its core,
You just need to know the part number you're looking at,
rack slot channel, if you're in
a huge panel that has lots
of different remote I.O. or PLC chassis-based I.O., and then typically
this needs to correlate one-for-one with your I.O. list.
So in the first video of this series,
we talked about generating an I.O. list.
That's how you know what actual tags are going
to get landed on each channel of your I.O.
cards.
And that's kind of the crash course to control devices.
So to finish, let's take a look at a
network diagram. So if we go back to our layout real quick,
you'll see really the only things in
this cabinet that are going to be networked together
are the switch itself and the PLC.
But for sake of showing what a networking diagram is fundamentally,
let's say that we have a PLC,
an HMI, and we're also going to connect to a operator PC
or like an engineer's PC.
And then let's say the PLC will
also be controlling one rack of remote IO,
and that's all going to be networked through this unmanaged switch.
At its most basic level,
a networking diagram should show you all components that are being
connected together,
which port they connect to in your switch or network component,
And then call out the IP address.
Most of the time, you should also include the subnet mask,
such as 255.255.255.0,
because in larger plants where you might be part of a SCADA
or plant-wide MES system,
it's really important
that you're correctly separating all network traffic into VLANs.
You may also want to include PROFINET names if it's a Siemens system,
or MAC addresses if you really want to be nice.
At its base level you need to show what should be connected
and in what port. This is extremely
helpful for troubleshooting
and also in the event you have a managed switch and not an unmanaged
switch, there will actually be virtual configuration
on your switch that determines
what can talk to what else over which ports.
So you may have other switches and you set those up
as trunk ports, you may have access ports
which means they'll only be able to talk to one LAN or
Or a few LANs with different segregation rules.
And so you could have PLCs and drives on one device LAN
and then switches on another LAN
and then computers on another LAN.
And so it's extremely important to have a schematic that calls out
which port what thing
is connected to and key networking properties about those.
So again, in our example here, this is a very simple one.
But if we were to look at a slightly more complicated one
from the Solus PC website
You can see a much bigger Stratix 5700
which is a managed switch, and here it's got the
remote I.O. rack and the main PLC,
as well as the panel view HMI, and a bunch of individual
cards and drives, as well as the PC connection,
all called out with specific locations, and
I know it's a little bit fuzzy,
but the IP and the subnet mask are called out for each,
as well as the type of Ethernet cable that needs to get called out.
Because even though you might just think like, oh,
it's an Ethernet cable, so Ethernet cable is what it is,
there are still types of switches
that could use M12 connectors instead of RJ45s.
There's Cat5 Ethernet, Cat6 Ethernet,
and not everything is compatible with every type of cable.
So even though the networking schematic
is one of the more generic ones to make,
it's extremely important to troubleshooting
and longevity of your panel to get it right.
Okay, so those are the major types of drawing
that we were going to talk about together today,
so why don't we also just touch on some
of the great things that this Solus PC website calls out,
just so you're familiar with core concepts here.
You have just straight line represents
a straight wire connection.
It can also be used for a cable, not a wire. And then a
basic connection will show something
at the junction that shows it physically connected.
While if you're jumping over and it's not actually making connection,
you could just have a plain cross
or you could have a symbol indicating that it jumps over that.
That's usually configurable in the software that you're using.
But if it's physically connected,
there should be something like a dot at that junction,
making it clear that that's actually a connected wire.
Our version would be like in the power distribution.
You see here we have this little.
Jumper this indicates that those are connected while
when they just overlap like this those are actually not connected
So I know that can be a little confusing
But that's a standard of if there's nothing at the junction.
They are not electrically connected
You need some kind of symbol like a dot or an angle to show
that they are connected push buttons and switches again
These are a little bit
Different between IEC and NFPA,
but you have normally open, normally closed and single
pole dual throw that are basically
these are very similar electrical icons.
And if you just look at any quick reference guide for IEC
or NFPA drawing schematic symbols,
98% of what you're going to see on those drawings will pop right up.
So you have limit switches,
push buttons that look a little bit different,
but the same idea of a push button that's normally
open and a push button that's normally closed.
Lights usually have little lines coming off of
Off of a circle.
Motor contactors.
In NFPA, they'll say MC, which makes them pretty clear.
In IEC, they might say M,
but they're this circle with lines coming off the side.
Motor coil contacts actually look like
the basic building blocks of ladder diagram too if you've
done any PLC programming so you have normally open
and normally closed contacts. And really
there are plenty of examples and guides like this online
so you can try to read up on them
before you actually have a drawing package in front of you.
But you can also go googling
when it's time and you'd need to make a first set.
The most important thing
Is that the schematic package you make would do two main things.
It will give guidance to the people
who need to build your PLC cabinet for you or you yourself
as you build the PLC enclosure, if you're doing everything yourself.
And then the second most important thing
is that it's a living document that as you add
on and troubleshoot and modify, you red line it up,
which is what making changes to drawings
is called.
And then you go into your drawing software
and you actually fix the package accordingly.
to whatever you've done in the field.
Those are called red lines. So it's a very important
troubleshooting tool. And then it's also a living document.
That's one of the reasons
which we haven't talked about the title block a whole lot
because I didn't really put a
lot of information in it here.
But you should have a revision control in the title block
as well, showing when you've made red lines and revisions over time.
what you've changed, who the author was, and when that got made,
so that these drawings also live with the plant
and the equipment over time as you make changes.
It's very important to keep them updated.
Okay, so I think that's a pretty good introduction now we've had to
taking an open-ended problem statement
and generating a piping and instrumentation
diagram, which has led to creating an I/O list,
which has led to creating a bill of materials,
Which let us make a panel layout,
which has led to us being able to generate some high level
electrical schematics to create a panel.
So I think now we should look at how a drawing set
actually converts to the real world and we build and test a panel.
And that should close out this
initial course with a really nice introduction
that can take you from absolute beginner to
relatively familiar with what you're looking
at in the world of industrial electrical schematics.
If you have any questions
or want to add tips for other people watching,
be sure to drop them in the comments below.
I hope you found this useful. Be sure to leave
a like on the video if you did
and subscribe to the channel for tons more great content.
As always, thanks for watching
and we'll see you in the next one. Thanks, bye.