Video Summary
AI GeneratedA technician inspects and repairs multiple HVAC systems in a home. The work involves diagnosing a non-cooling unit with a failed capacitor, troubleshooting a power issue with a faulty transformer for an air handler, and identifying electrical shorts and burnt wiring in a third system.
This is a house with three systems.
I think it's this one that's not cooling
and there's one
with a blank thermostat.
Looks
like
my high
contactor
is
pulled
in. The
compressor
is not
running.
Let
me
see
what
we're
talking
about.
All of this has, judging by this,
this has caught on fire at least once.
You
see
this?
The
start
capacitor
is
actually
a
little
bit
warm.
It's
got
some
bubbles
on
it.
There's
a hundred
and eighty
three
microfarads.
I don't look
to help you
though
You get
self-tapping
screws
for
that
deal
with
this
start
kit
here
Common
cut
here
and
super
boost
instead
of
that
one
with
a
relay
This
start
now,
excuse
me,
this
is run.
This
is
common
and
this
is
start
let's
see if
it'll
start
now
feel
that
that's
nice
and
cool
we got
a big
train
air
handler
down
here
with a UV light it looks like electronic air cleaner i don't see
no indication that we got
power
i
think
i'm
gonna
check
this
this
disconnect
first
outside
i
got
240
how
do
they
read
that
i
got 28 volts i'm gonna show you what i found
on this transformer on this i continue to have
problems getting 24 volts
to the thermostat just randomly
for no reason i want you to listen you
hear that sometimes it has 24 volts sometimes it don't
that's hot right there you gotta be careful
so
um i
think
they
might
get
a new
transformer
yep
that's
what's
fixing
to
happen
and if
you
read this common
is white orange
is two four eight
white
to white
on that one speed
okay
this
is
the
other
one
I
got
it to
call
and
she
said
it's
been
cooling
fine
but you see this i got
the power pulled right there it looks like it was short
this right here
is burnt we got some
fixing to do on this