No cooling, easy diagnosis, and correcting problems found.

HVAC GUY
26 followers
Tools I Use In My Videos 👇👇👇
https://www.amazon.com/shop/hvacguy
There was a moment in this video when I suspected that the run cap bandit used to work for me. Replacing a capacitor, and doing it right.
#hvac
#rheem
#capacitorbandit
#capcitor
AI Generated·May contain errors
Video Summary
AI GeneratedThe video demonstrates the process of replacing a faulty capacitor in an air conditioning unit to restore compressor functionality. The technician identifies the issue, installs a new capacitor by matching the correct terminals, and verifies the repair by confirming the compressor is running and the system pressures are stable.
All right,
we are set to cool on 73 degrees and it's 81 in here.
So let's check it outside.
Don't feel any heat coming out of that.
And I don't think I hear the compressor running.
Look
at what
we got
here.
Y'all see that?
That shock lets me know that that thing was about to shock me.
That little spark right there.
A new capacitor and I'm going to mount
that thing in there like it's supposed to be.
Now
that
wasn't
that
hard
to
do.
and mounted it in there like it's supposed
to be something
when you see these this particular name
brand and a lot of capacitors i can't read herm common
and fan but i can see this one has four
spade connectors this one has three and this one
has two the one with four is my common or run and
the one with two is is fan
and the one with three
is hum all right that felt
a little bit loose
i'll tighten that up everything else is good
so let's um turn it on and see if our compressor
don't come on compressor came
on and started running all we got
to do is um check pressures
all right now you give me
a while to get there
but pressures are fine
like it's supposed to be now
they're doing fine
this is a 410 system
still be doing fine
this one was an easy one