If You’e In The Albany/Leesburg area of South Georgia and wish to set up an appointment, https://clienthub.getjobber.com/hubs/b20c8ec9-030a-4d13-baba-aa8a3d21a5b2/public/requests/4981900/new #hvac#airconditioning#airconditioner#hvacguy @ACIQComfort @Jobber @BlueCollarWarrior @HVACRSurvival @yessimoli4263 In today’s video, I go to a customer’s house who complains that after having the utility switched to his name the power was turned off, and then back on when the power came back on his air conditioner did not. I’m going to go through the electrical troubleshooting of what happened to the system and how I fixed it. I hope you enjoy.
AI Generated·May contain errors
Video Summary
AI Generated
A technician returns to a home where a mini-split system stopped working after the power was cycled during a property ownership transfer. The technician diagnoses a power supply issue and a failed transformer, replaces the faulty components to restore cooling, and notes a potential refrigerant leak before sharing personal home renovation plans.
Hey guys, in the video I have for you today, I'm actually going back
to a place where we installed
a mini split about a month ago
and um, the house just sold, the new people moved in and they had
the utilities switched over to their name
so they killed the power and then turned the power back on
When the power came back on, the air conditioner did not start up
and it had been running before, that's why he called. Come with me
I imagine y'all been in here
working, yes I have, I've been
working, all right, where are you
Okay, oh we have a
Vivint thermostat
Did you just turn it
on? Yes, okay, we might
be waiting on a time
delay check
it outside
and see what
it's doing still
flashing, so it
does look like
everything's
turned on, I think that was a little
anole lizard y'all just saw, okay opening
this right now is not
going to help me a whole lot better
to take the whole top off
This is the setup in these systems
That's your evaporator coil, condenser coil looks pretty dirty
This is the back side of that coil
It actually pulls air through here this way
and blows it out the sides, but right now it is not
coming on at all, so it's got new batteries in the thermostat, yeah
but the battery is reading low
do a new one
yeah 240
volts that
actually
looks like
my voltage is
coming from
somewhere
else
y'all can't see
that but right here i'm
reading 120 volts that should
be 240 it's like right here
i'm reading 240
so we have a whole
nother circuit just
for that and i think
we're missing the leg
okay
so
we're
gonna
check
i'll
try to
turn
that
where
y'all
can
see it
tell
you
what
okay
so we
need let me see if i can reset
that i didn't get that could you
try again i'm only getting 114
volts so y'all hold
on just there's something
to see in there hold
on i'm trying to just get a
light that's burnt it's gotten hot
that one looks good let's pull
this one out
that one looks decent
let's see if we can find that is that's
a 50 amp i don't need a 50 amp though let's see if we can
find them
a breaker and
move it over
to the right
it'll get you
i get paranoid
where's
that one i
brought i know i just said it here it is right
between my legs all right what i'm installing
is a 30 that'll better protect
just basically the condenser
fan motor and the compressor on
that
circuit.
I'm gonna
move
this.
Those
terminals
back
there
are
burnt. I'm
putting
it on
some
unused terminals here.
Put that in.
I can tighten it up
a little bit. I'm gonna put
the top back on
before I put power
to it.
It'll hurt nothing
if it comes on.
We got 240.
What we got up here?
We're about to find out. Now when I push this in, it should come on.
Try to show the troubleshooting.
I want to make sure the transformer's getting 240 volts. I have
trace these wires back to the top
of the contactor transformers
getting 240 volts one of my low
voltage wires this one
is grounded so that's going
to be my common and this one
is my red that tells
me i don't have 24 volts
just going to confirm i
got some bare wires here
240 ground to here and
i've got zero volts it needs a transformer
and we're going to have to fuse it because we don't
know what blew it so transformer fuse
and then we can troubleshoot whatever blew it checking oh
checking to ground nothing nothing the fact
that this little low voltage little breaker on here
that's a three amp did not blow
and all of this happened right after I turned the power back on
makes me
suspicious
that it may
just be the
transformer
I hope
so this hot
that went to
something
tap
there
it is
right
there
that's
not the
one i
wanted
to get
let me
go get
another
one
much smaller 40 va
transformer first
thing we need to do
there's a legend up
here primary is white
and then 240 is orange so we need this one
and this one but these right here we're gonna cut
cap off so
these two need
to go to power
this is one
and this goes
to my other leg
of power
which is this one i'm
sorry this is taking
me a while it don't
matter as long
as you get it right
i'm gonna do my best i promise you
that okay we got high voltage connected let's cap those off
okay so basically these little transformers
are the same thing that's on the pole outside your
house it converts a higher voltage
into a lower voltage we use 24 volts for controls in our
thermostat because it's safe very unlikely to spark
and cause a fire okay only the transformers
on the pole out there they're like um thousands of volts
and this starts with 240 and converts it
to 24 over here
on my common
and i'm keeping my
common grounded
but this one's
going to be my hot
i'm actually going to leave
this right here because i'm going
to use a fuse stick that in
like that it just looks like i don't have another
one exactly like that it'd be nice if i did
don't want that
metal touching
anything
so i'm going
to wrap that so
when i connect
that i should
have low voltage i'm gonna go ahead
and put power to it we know
that one side our common
is grounded so i'm gonna
test right there tell
you what 240 this is
the side i need to test
to ground i now have 27 volts if y'all can
see that i'm gonna hook that up like this
it's better than what we had it
sounds like it just came on i
wanted to show you something over
here watch your fingers now you see this right here
that oily spot that is very likely a leak
of refrigerant
so prepare yourself okay
well guys i know that system
has a lot of problems and so
as a homeowner i'm gonna take you out right here
this is part of my back porch it's a hot tub
that don't work a bar that i don't use
because i don't drink and here's the rest of my porch
and deck i'm showing you this because they have lowered
the river just so we can make repairs
and work on our property and probably
so they can clean up around the dam i'm taking advantage of
this time to redo the dock redo all of this
everything's coming out and i want like an
outdoor kitchen with a refrigerator
um nice grill do something like
a pizza oven a fire pit that's
what's coming and it's starting tomorrow
that's why i'm telling you about it i hope you enjoyed
the video if you did how about like and subscribe
and hey please check out my merchandise store i
am starting a merchandise store i'm trying
to figure out how to get it to hook up to youtube
had a little trouble with that but um it's
in the description click on it i've just started
adding some products and it allows me to upload any design i want
so i can get some really cool
stuff in there and i'm just starting
so check it out i'll catch you on the next one