Good morning guys we are at an airbnb. I already turned it on inside and as you can see my
condenser is not running. This may have a float switch so I'm probably just going to go ahead
and clear the drain and we're going to open this up and see what's going on. Stay tuned.
I've gotten used to using this railer magnet. The whole thing's nice. Okay y'all saw one lizard
crawl out of there. That's pretty bad. Pretty bad. Here's a couple more lizards. There's one.
There's another one. Man it's like a mouse has been building a nest in here.
Man. Okay it looks like my thermostat wires go straight to the contactor.
Pushing in the contactor lets me know we do have power. I'm just going to test on this contactor
because these wires just go straight to the contactor. There's no safety switch.
I got no voltage. Let's clean out this drain.
Let's see if anything comes out. I'll be honest I don't know what kind of refrigerant I'm looking
for. There is nothing that tells me what kind of refrigerant this is supposed to be.
I would probably think this is an R22 or at least an R22 substitute. So I'll put this on
R22 and it'll give you those temperatures. It's evaporating at 45 degrees.
Inside he was saying it just wasn't keeping up. That's because it wasn't draining fast enough.
It's pretty much an easy fix. While I'm here y'all saw how bad this looked. I'm going to
clean that up, check the capacitor, and I'll try to show you that contactor.
Contactor's not in the best of shape. Just put it that way. Capacitor's been replaced before.
There is a way to check it while it's running. I'll tell you what. Why don't we do that just
to show how to do it. I got to pull up a little note that tells me how to do it because I don't
do it very often. But I'll try to share that with you. All right that picture right there
I'm going to try to let me see if I can get a screenshot of it so I can share with you.
That teaches you how to check a capacitor while it's running. Okay the way to check these
it's got a little formula here. First thing you do is check the capacitor.
Measure start winding amps with an amp meter. We're going to do the for the
condenser fan motor. Start winding on it. It's brown. It's a brown wire. I've got 0.7 amps.
And then we have to measure voltage from what is our C. It's actually our run winding.
348 volts. Okay so what we do is this one's going to be for the compressor.
You see we have 4.55 amps. I got to remember how to do this. 4.55 times 2652.55.
It gives me over 12,000. And you divide that by the voltage from run to start. The one that
you're checking. And that one's got 360 volts. 33.51. Plus or minus 10 percent. So what I'm
going to do is 35 times 0.9. I think we're pretty good. To mention these capacitors normally come
rated as 370 or 440 volts. Or sometimes it says both. Either or. Basically that voltage
rating is how much voltage it can handle before it shorts between the terminals. I'm going to
show you. We can measure that. That right there is 359 volts. So technically a capacitor that's
rated for 440 is a better capacitor. It can handle more voltage between those two points
before it gets too hot and shorts. But a 370. You see how close we're getting to that rating.
359.4. You give this thing on a good hot day and another complication like maybe a
loose connection or something. And that capacitor could fail if it's a 370 very easily.
Just replace that capacitor. Holy smokes.
We didn't replace the capacitor. We replaced the contactor.
And we're about to throw power to it. As you see everything looks good.
Forgive me. I was looking for a zip tie. I was going to try to make that look a little better.
Looks like I don't have one. I'm going to move this wire from the bottom. That is on the side
that does not have a break in the line. So it doesn't matter if it's on the spade connector
here or there. One thing you should always remember is that this wire. That one right there.
The one that feeds power to the capacitor. That side is always run. Now on this one it was color
coordinated. So you know this is run. So this is run for the compressor. That's run for the
condenser fan motor. And these are common for the compressor, condenser, fan motor. And these
other two wires right here are start. The capacitor is always between start and run.
We know this side is run. Feeds over here. So these two are start. That is start for the fan.
And the blue one is start for the compressor. Let's see if I can make this right here look a
little better. All right let's put our panel back on. Okay so that was kind of a weird experience.
There was nobody right here. I thought I perceived someone. But as soon as I got on the other side of
my truck over here. There was someone. I got a little weirded out there for a sec.
I do hope y'all enjoyed the video. I recommended a preventive maintenance.
I don't carry R22 on my van constantly. That we now have to have
multiple refrigerants. And I do have an R22 replacement. So if that one's riding along
as well as it is right now. I'm not gonna mess with it. I'm not gonna try to charge it. I'm not
Catch y'all in the next one.