Lecture 46 : Far-Infrared Spectroscopy

IIT Kanpur July 201
20 followers
Sep 26, 2024
So, welcome back to this week. Last week we concluded the lecture session with the disadvantages
of the Riemann spectroscopy. So, that is why I put the slide in front of you. So, we talked
about that Riemann spectrometer which consists of lens and capturing part of the scattered
radiation and directing it to a filter to let only the Riemann scattered light to be
sensed by the detector. So, we have realized that Riemann shift fortunately
interference and instability issues prevent Riemann spectroscopy from providing accurate
glucose measurement in vivo. So, due to this reason though Riemann spectroscopy is a very
powerful tool for in vivo glucose detection possibly, but it is not currently exploitable
at the commercial zone because of too much noise in the signal.
In the same line in the last week I told you that we will talk about far infrared spectroscope.
One thing to be realized when you talk about the far infrared we are trying to detect the
weak bonds, weak vibrational rotational motion which are prevalent in the biological systems,
but you really needed a very unique signature when you are trying to do that from outside
means in vivo. When you are taking the pure sample and putting it in a spectrometer it
is a different story, but when you are trying to read these or get these read outs directly
from a subject human or an animal or any other moving system or living system there are lot
of interferences. And as we talk about far infrared spectroscopy which is also called
as terahertz spectroscopy is based on the principle of absorption due to existence of
particular vibrational and rotational transition of weak bonds and bonds of heavy atoms approximately
between this is the number you have to realize 0.3 terahertz which is 1000 micrometer to
30 terahertz which is 10 micrometer. The lack of information on FIR or far infrared
means that the technology is still in its infancy concerning the field of non-invasive
glucose detection as I have mentioned. Since the strong absorption of water and the low
level of power delivered by terahertz sources do not allow detection of meaningful data
using standard NIR, MIR methods. Nevertheless with the advent of quantum cascade lasers
OCLS or quantum cascade lasers now it is possible to use time resolved far infrared spectroscopy
also called terahertz time domain spectroscopy for biomedical application in the sub millimeter
wavelength range. So, this is the part which is of significance of the use of quantum cascade
lasers QCLS just corrected. So, this is QCLS it is possible to get a time resolve far infrared
spectroscopy and this particular development in laser technology has opened up lot of opportunity
for using far infrared spectroscopy for near future for in vivo glucose estimation, but
not with the traditional far infrared spectroscopy, but using QCL techniques.
Next area where there is lot of work which is going on is time of flight or TOF which
is the mass spec and terahertz time domain spectroscopy which we talk about T H Z and
T D S. T D S stand for time domain spectroscopy and T H Z stands for terahertz and that is
the short term time of flight we call it a TOF. So, we need TOF uses a single frequency
very short laser pulses in order of picoseconds to measure the radiation absorption and time
it takes photons to travel across the sample. So, you are using the laser pulses in the
order of picoseconds to measure the radiation absorption and the time it takes photons to
travel across the sample it uses the same spectroscopic principle of absorption and
scattering, but from a time domain perspective to get the phase change as an additional parameter.
This is the part which is of significance of phase change when light propagates through
the sample some photons will follow a direct path towards the detector while others. So,
some will follow like this while others will follow a longer zigzag path due to multiple
internal reflection to the detector stand say for D and others will go through the total
scattering giving rise to diffuse light. Analyzing the time of flight distribution
of detected photons the change in the pulse shape and pulse broadening due to scattering
and absorption level it is possible to detect the optical properties of the medium including
glucose concentration, but when I am making this drawings you must realize that when we
are talking about doing such analysis in vivo there are lot of noises and interference.
If we could bring these down and definitely one can get a very unique signature Alrazo
et al this is the author described a typical set up for measuring glucose in vitro. You
can see they are using it in vitro with top using 35 picosecond pulses with a wave length
of 905 nanometer hitting a sample and an array of 5 optical fibers collecting the scattered
light from the medium and directing them towards camera to record a temporal profile of the
detected pulses besides Alrazo's measurement top needs further study for glucose monitoring.
So, when we are talking about say for example, here you have a sample in a cubit pure glucose
sample or a blood sample or urine sample or any other sweat sample. So, these are the
samples where the laser light could have a direct accessibility they are in a laser.
So, you have a direct accessibility, but when we are talking about the skin you are trying
to do this in the body there are lot of layers you have the skin epidermal layer sub epidermal
layer before it reaches to the blood vessels. So, during that process there is a lot of
interference and noises which are generated and this is the major problem whenever we
are talking about time of light time domain spectroscopy at terahertz level all this techniques
suffers from these interferences. So, most of the spectroscopic technique while they
are some of the finest signatures yet when you translate them from in vivo to in vitro
the equation changes. So, if there is a way that in vitro data could be corroborated with
the in vivo data same signature then these techniques will find place in day to day in
vivo measurements of glucose.
Now, next we move to another form of a spectroscopy which is called thermal emission spectroscopy.
So, we all are aware of the fact that due to the metabolic activities in our body our
body generates heat or heat radiation. So, while our body generates a heat signature
it is a cumulative of all the reactions taken assume from that heat signature or the radiation
if we could detect the level of glucose. So, in other word the generation of heat is the
cumulative of multiple metabolic processes with the body, but from there say for example,
it is contributed by 10 parameters if you could pick up the glucose parameter then you
will be able to do. So, we are talking about thermal emission
spectroscopy which in short they call it TESS uses the principle that human body naturally
emits energy as heat in the far infrared bands between 8 micrometer and 14 micrometer. So,
as a matter of fact animals detect human using exactly that kind of far infrared sensing
as a matter of fact snakes use these kind of technologies they could sense.
During the process of leaving the body part of this radiation is absorbed by different
molecules in the body including glucose around 94.4 micrometer wavelength. So, while body
is generating them there is this glucose which is absorbing it before it goes out. Now, meaning
that analysis of the intensity and characteristic of such radiation figure will follow provides
useful information on the presence of the concentration level of glucose in the tissue
with reasonable specificity. So, in other word say for example, here you
have a cubit where you have the glucose molecules in some kind of a solution. Now, here is the
far infrared bands now when they are passing through say for example, some of it is getting
absorbed by these molecules and what is going out is after the absorption. So, now depending
on how many particles are there number of particles increases then automatically there
will be more absorption and that is what it meant by provides useful information on the
presence of concentration level. Now, this is one of the profound possibility
thermal emission spectroscopy and here is the picture. So, for example, these are the
heat generated by the body this is the body tissue. Now, there are lot of glucose present
depending on the concentration of the glucose what they are absorbing. So, this is the original
say for example, radiation amount because of the absorption there is a lesser one here
and here is a thermal sensor if it compare depending on the glucose level of the body.
So, you back calculated by using another technique that say for example, from this tissue you
draw the blood draw the blood and measure the glucose by another in vivo or in vitro
technique. Now, similarly you feed the animal with sugar and then you draw the blood and
measure the glucose. So, now you have without sugar you have glucose measurement with sugar
you have glucose measurement and the thermal sensor will have two different kind of absorption
which will come and that absorption will give you amount of glucose versus the sensitivity
or what the thermal sensor is telling and this is the basis of thermal sensing using
thermal emission spectroscopy. So, this is another profound technique. So, these kind
of technologies needs a lot of testing with the in vivo, in vitro and here it is a in
vivo measurements. This in vivo and in vitro measurements when you quantify them together
what you get is the deviation from the in vitro to in vivo data. Now, that deviation
is nothing but say for example, your in vitro says x amount of glucose and your in vivo
says y amount of glucose. That means from and assume that y is less than x that means
that amount which is less is x plus delta x will be equal to y. This delta x is the
amount which is getting lost because of interference and other losses due to the presence of other
absorbing molecules which are of similar nature. So, unless these two values that in vivo is
correlated with in vitro value and the error level is being determined these sensors will
need a lot of work before they get commercialized. It is almost like think of a thermometer which
is measuring temperature, it is a mercury thermometer. That mercury thermometer has
gone through many decades of perfection when now we know that this much rise indicate this
much change in temperature. Exactly like a mercury thermometer here we have to figure
out with how much increase in glucose how the radiation changes.
Second part of this thing is that this tissue is depending on what is the physiological
status. First of all a gender is it a male or a female then comes there are races who
have better they generate more heat their metabolism is higher. Say for example, is
the subject a Caucasian or is a subject is an Asian or a subject is from people with
a darker skin coat or they are coming from places which are extremely cold or they are
coming from places which are extremely hot or they are coming from places which are having
high altitude or they are doing some special kind of exercise like underwater exercise
or other things or in the submarine depending on your physiological status the heat generation
is altered in the body especially those who work on sports medicine they all realize it.
So, unless we have tons of in vivo data corroborated with the in vitro data it is very tough to
get a exact picture in theory these are fantastic techniques, but in terms of practical applications
they suffer from series of challenges which have to be overcome in the decades to come.
So, however, just reading and interpreting the radiation absorbed by glucose is not enough
to provide accurate reading due to small amount of thermal energy involved and this is another
part thus TES also compares the reading with a predicted amount of thermal energy using
Planck's distribution function in which the measured data is the intensity reference level
upon which the actual thermal absorption is calculated and then converted to glucose concentration
level. So, you see the complexity and that whole
picture will make more sense to you when we talk about the Planck's distribution and from
the Planck's distribution you are measuring the intensity of the small amount of radiation
what you are getting unfortunately although in theory as I was mentioning this technology
seems to be straight forward it is a pretty straight forward no significant research has
been put into it as such there are several limitations that needs to be addressed most
acknowledged experiment using TES is the one performed by Bouchard back in 2004 in the
tympanic membrane, but actual in vivo results need yet to be published.
So, this is something what looking that though in theory this is one of the most beautiful
technique, but when it comes to the practical applications it suffers from series of drawbacks
and unless these drawbacks are met unless these challenges are being rectified and corrected
these technologies will not be able to make the cut for commercialization same as what
we discussed about time of flight and terahertz domain spectroscopy same is true for far infrared
spectroscopy. So, while most of these technologies are of
immense importance they are extremely challenging there are places where these technologies
would be utilized in a very different context when we talk about situations like where you
have soldiers who are put in desert war to your system or in a high altitude system or
there are force situation where you have to go through some special training there these
kind of data is amazing because you exactly know the condition in which you are putting
the individual or the human or in case human subject there you can get extreme of the extreme
data. So, one of the things in management of these
kind of sensors resuming in 20 years these will become the technology or technological
break through one needs to generate data from extreme environments because these are really
potential tools to get generation of data from say hyperbaric hypoxic situation where
there is a low pressure and low oxygen body has to really fight it out or you are in a
submarine or you are going for a deep sea dive or you are going for a scuba dive or
you are in a space or you are going for say a desert warfare system.
So, much of these things and second part is that these data needs to be verified across
the different races, different ethnicities because these have potential, but this needs
a very broad level of data collection before we have a clear picture of how these data
could be utilized or could make sense in the longer run of commercializing this technologies
especially while we are talking about sensor integrated suits or warfare system, bio warfare
systems these are some of the tools. See stand alone none of these will make sense, but when
you integrate them with multiple technologies they all will make sense.
Say for example, you have a suit in that suit you have all these things integrated you have
a thermal sensor, thermal sensor sensing it and there is a software which is embedded
into it which is doing all the Planck's distribution and deducting from the Planck's distribution
possibly glucose level and you have a sensor which is the other sort of sensors which are
present in the whole system. So, you realize that much of this sensor business will use
lot of printed electrodes which we will be talking very soon or next week or this week
lot of miniaturization, lot of body line integration where much of the sensor technology
will capitalize for in vivo recording. So, we will close in and the next class we will
talk little bit more about the rest of the technologies for in vivo glucose sensing.
Thank you.