20 Year Old Gas Pack - Condemned??

HVAC GUY
37 followers
Tools I Use In My Videos 👇👇👇
https://www.amazon.com/shop/hvacguy
Home owner called me out because of no heat. Said nothing was working, and revealed that the previous company had condemned the furnace, saying it was dangerous! Not true. It just needed a thermostat! #hvac #hvaclife #fieldpiece #makita #furnace #hvacguy #hvactech #hvactechnician #vetopropac
AI Generated·May contain errors
Video Summary
AI GeneratedA technician inspects a heating system that a previous contractor claimed was dangerous and condemned. After a thorough diagnostic process, the technician discovers the system is functional and the primary issue is a faulty thermostat and dirty components, contradicting the previous recommendation for a full system replacement.
Before I start this next one, before I show you,
during the process of the call, I found out that
the homeowner had called somebody else and they said it was dangerous,
condemned the unit, and
quoted her a new system.
That's not what I found.
Stay tuned. Let's see,
the fan comes on and we'll
turn
on the heat,
see what
happens.
See my
thermostat
wire
running
through
the return.
All right, let's see what we find.
Do you think they put enough screws in this panel?
my water i'm still
not done first i'm gonna check and see
if i'm getting a call i think she said
nothing was working so uh i know we got power
and i know we got low voltage
because the blower came
on even if i can get this to run
i'm gonna have to pull off the top
and look at that heat exchanger
before i let it run for any period
of time i am not getting
a call all right before i go into the
thermostat and try to jump it out i'm gonna go ahead
and kill power and take a look in there i
think that these
had a stainless
heat exchanger
a hundred screws
by the time i'm
done there that's
just crazy nothing's
really nothing's
really sticking out
at me it's got
some discoloration
but very little
rust looks like
that blower has
been replaced
that condenser
fan motor has well
that may be original all right
i'm gonna put power back to it
and jump red to white and see what
happens
there's
a chance that
thermostat
could
not be might
not be hooked
up right i'm
lucky that
didn't
blow my
transformer
all right so
it fires up i
don't want it
to get too
hot really
suspecting
that thermostat because i know it's been changed
in the meantime i'm gonna pull that flame sensor
and clean it
and hit it
right at the
beginning
oh my god
something
holy smokes
that was hot
running a risk
of breaking this so i'm
not completely off not not
going any further anyway
i don't think
that flame
sensor's ever
been cleaned
it still
looks dark
but that's a lot
better because
that was so bad
also pull that
that sparking
out of there i'm sure i got
a short and
stubby
for
that
too
big
trying
to be
real
careful
to
break
these
things
this
ceramic
when
it's
new
is pretty strong
but as it's exposed
to the heat it becomes brittle
so you can break the ceramic
even
though
the metal
pieces
are still
intact
and those
metal
pieces
can break
all right
let's go
check on that thermostat real quick
i'll start upping this then all right
the thermostat's wired
correctly but every single connection on it was loose
so i tightened them up and let's see what
happens still
nothing let me
confirm that i
do not have
a call nope let's go
in there and jump
out the thermostat
that may be your
problem i'm about
to find out oh that's
may give up those wires
are all kind of kinked in there all right so we know
it's the thermostat that's pretty easy to fix
i'm gonna program
this before i take it
in there let's
do the heat type standard
efficiency this
one out all right
so time's accurate
so all we got to do is take
this in and change it and then put
that package in one of those Robert Shaw thermostat
that has to be pushed up pushed up red blue is
common green yellow w if i got
that programmed right it'll come on when i put everything back
together
this is
actually
a pretty
good
design
burners
are well
off the
ground and
the good
so those first two numbers right there i think are the year
so this is a 21 year old system
I'll get the heat running and everything
and then I'm just going to turn on the cooling
and make
sure it
comes
on let's
see if it
comes
on that's
blowing
out warm
air
surprising
but it is
it's really too cold to check pressures right now
so I'm just going to put it back on heat that's
what they want and uh I think this one's done
happens to be really late you like that video
please like and subscribe. I got more coming. Thanks for watching.