If you’re interested in more business related videos I’m starting to publish them for members. In time I plan on have a full selection on how to manage and complete every step of opening and running a business! Join this channel https://www.youtube.com/channel/UCiz21FXLOV65NTgiUfJsxTg/join
As you can tell it is Georgia game day
and I brought you out here so I can show you that.
That is my dock. It is being partially rebuilt.
The whole process of rebuilding all
of this over here is in the process.
The video I have for you today contains a
very active little puppy in it. I think you'll enjoy it.
It's just part of my week. Last week
customer called and said his air conditioner wasn't cooling stay tuned
yes you are you a big puppy you just wanted
to see what was going on yeah yeah yeah oh oh is
he gonna get zoomies come here come here come
here come here i'm gonna get you come here
you're a sweet boy are you gonna help me
are you gonna help me you know you you ain't qualified
had to work on an air conditioner
and i'm not hiring anybody right now all right now that's
enough
that's
enough
go okay
that's
enough
good
boy is
that all
that was
in that i
can feel
like
it's trying pouring
water now i'm gonna
check pressures
at least this suction
here because i
want to make sure it's not freezing up
that certainly feels like it's getting cold so i
replaced a condenser fan motor on this not too long ago oh
this is r22 fabricated 2012 that
must be a field charge okay so my fear of what may
be going on is true this thing may be freezing up
i'm gonna check superheat real
quick basically the superheat
will just tell me if i have ice
up there right now all right
my saturation temperature is 29 degrees
and i have 31 degrees
superheat well i might have some ice up there
but that's what's been happening if that saturation
temperature is below freezing
no matter what refrigerant you're using there's a chance it
can freeze up not good we are going
to turn that back up i don't want it
to run my filters here
and i think my air handler is up here i
am pretty sure my air handler
is back there it's time to
throw some
pillows
around it
is a little
bit odd i'll
give you
that and i
see why that
that elbow
was turned up outside i told you it needed a p-trap
and it's got none i'm gonna have to leak
search this coil
because it is low on
refrigerant this is
an old r22 air handler
okay we got us an
old copper coil here
i can't help but
suspect of leaking
that's good enough
well one thing's for
sure that is not the original TXV
this has definitely been worked
on before i am i mean
i just switched
that to high for
giving it give me
that slightly
shaky this is one
of those cases
where i believe this is leaking
and i'm going to search it like i know there's a leak somewhere
i'm gonna
let that
recalibrate
a second
all right
so far i'm
a little
surprised
all right
so far
the
only
time
it's
going
off is
when i
bump it
y'all
can
tell
that
only
part
of the
coal
was
getting wet it got wet up to here
and it looks like this bottom part may have gotten wet almost
all of that
is dry
that's wet i'm
not half
believing
what i'm
finding
we might
have to
go search
outside a 19 year
old coil and uh i'm
not finding a
leak i gotta make
sure that's the
right one well i see you're back
by the way this little puppy here
is five months old he's a
youngin i'm just making sure we
don't have power right now there's
my ground no power no power
They don't know it, but this fellow is fixing to come home with me.
Riley's fixing to have a new friend.
I've taken the caps off, the Schraders,
and I'm taking this part right here
because I'm about to do a leak search.
There's a reason I normally check up top first.
Single sign of oil anywhere.
This is going to be a tough leak search.
I might end up recharging this.
All right, let me get my sniffer out.
Let's search around
that reversing
valve
and quit bumping it.
and
every
time i
touch it
i found
absolutely
nothing
in there
that's
just
a one i've
got i
just got two bars on that that's nothing abnormal
to tell you the truth especially after i've just
recently checked pressures do you know where
the leak is are you trying to tell me no the problem
is not that got permission
to charge it up
but because this is a field
charge system it is not
marked it's been worked on a couple times i
don't know what's in it so i'm going to recover
everything you know
down to like 3 psi
and then i'm going
to charge it
with the 438a turned off
these are still open i'm reading 28 inches
of mercury i'm gonna go ahead go ahead and let this
pull for a while now that i've got everything i can recovered
so that i have as much virgin r438a
as possible while that's pulling the vacuum i'm down
to about a thousand microns i was looking at
this crafty work right here
that is half inch i decided
not to replace the dryer because i never
let it lose all of its pressure
so no atmospheric pressure actually got in the system i started
pulling the vacuum
when it still had
like three psi on it
okay that is turned
on y'all see my
microns my microns are at about 700 i'm going
to go ahead and close this off this system was never
open to the atmosphere 700 microns
is pretty good closed it off i'm at 682 and i am ready to
charge i'll tell you what i'm gonna go ahead
and get my scale that way i know exactly how much
okay on these dry charge units
factory charge is zero ounces
so the nameplate ain't really
going to help me but weighing it in that way i have
an idea of what to charge okay now i think
i'm ready let me zero
this out again let's turn
this off okay vacuum is
holding at 664 i'm going
to open this up to go ahead and charge
and in just a minute we're going to turn on that breaker
i'm going to go ahead
and turn off this side
over here so we're only
charging to suction
for a second i'm at about
70 ounces there we go r438a
saturation temperature
right now is 23
degrees i do not have an accumulator
in here hope y'all can see
that that might help a little bit
we do have a txv in there i'm watching
my head pressure and the suction
saturation and my sub
cooling at the same time those are the main things i'm looking
at right now this is still below
freezing at 30.7 degrees five degrees sub
cooling we're getting closer now remember
these pressures
should be similar
to R22 if you're used
to R22 pressures
so getting close
to 200 is normal okay
so 195 head pressure 9.6 degrees sub cooling
i got about 60 psi on my suction saturation
temperature is 37.6 33 degrees superheat it
is like 72 degrees in there so that superheat should
be lower that sub cooling should be a little bit higher
and that vapor saturation should
definitely be higher figure i'd
take a second if you have low
head pressure low suction low
sub cooling and low temperature excuse me forget
the low temperature low pressure low pressure
and low sub cooling almost all of those indicate
that the system may be low on charge but that
super heat it is high that's the one that is opposite if that is high
and these are somewhat
normal that makes me think the charge is low
my saturation temperature is at 37 degrees right now
so we're getting much closer i kind of want
that closer to 40 keeping an eye on sub cooling
sub cooling 12 14 degrees
is not abnormal
and here we are right
at 200 psi 14 to 14.7 degrees
sub cooling i have 25 degrees superheat
now look at that vapor saturation i'm
at 41 40.6 right now
i'll keep an eye on it we're getting really close
to where we want to be okay i hope you can see
this 205 head pressure i have 16 degrees sub cooling
which may indicate it's slightly overcharged
but my super heat is 21 degrees that's
a little bit high vapor saturation is at 42 degrees
there is a reason i am not charging anymore
and it's not just a sub cooling this is a heat pump
so this will switch over to heat
and it's real easy for something like this to cause high head
pressure because this is not r22 it's r438a it doesn't react
the same in the system and you need
need to leave yourself a little bit of room
because when it goes into heat the air handler
becomes a condenser and that coil is not as big
so you need to leave yourself a little bit of room
i'm gonna leave it just like that i can look
to see how much 122 ounces seven pounds 10 ounces
that's about right this is a two
and a half ton seven pounds ten
ounces i do hope y'all enjoyed
that video and this is probably going to go live during
the Georgia game, Go Dawgs! If y'all do like
the video please like and subscribe check out the store in the corner
and y'all have been requesting
some merchandise, some HVAC guy merchandise, it
is live now the store is live there's a link in the
description and there might be a couple products under the video catch
y'all in the next one