If You’e In The Albany/Leesburg area of South Georgia and wish to set up an appointment, https://clienthub.getjobber.com/hubs/b20c8ec9-030a-4d13-baba-aa8a3d21a5b2/public/requests/4981900/new #hvac#airconditioning#airconditioner#hvacguy @ACIQComfort @Jobber @freezetheheat @BlueCollarWarrior @yessimoli4263 In today's video, I visited a customers home who was complaining that his air conditioner had stopped cooling, and the condenser fan motor was not turning. As I was diagnosing a faulty condenser fan motor the electrical disconnect failed on me. So first I have to replace the disconnect and then I got approval to replace a condenser fan motor. But that's not the end of the story. The family did not want to come off the shaft. I hope you enjoy.
Hey guys in the video I have for you today um
customer basically told me it's not cooling and the condenser fan out back stopped turning.
Stay tuned. We're all together. Fan stopped spinning in the back. Okay let's take a look.
Turn that breaker that uh breaker switch off. I did turn it off. Okay good good all right.
Hello I've come to check on this air conditioner. Come on in. All right.
And I did last year I did turn that switch off. Outside? Outside. Okay um can I walk around the
side to get there? Yes sir. You can buy those things right here. Those covers right there.
Yes sir. Y'all think y'all want another one? That one's messed up. I can talk to them and see
what they say y'all. Oh. How much are they? It's making a noise. All right what's the green
supposed to be? It looks like a 5.1. That nice capacitor and it deserves to be mounted correctly.
Got no power. It looks like we what is our blue here? That's a 45. Remove the whole thing.
All right let's test. All right this is going to be my common
and this is going to be my herm if y'all can see that. 43.9 and this is going to be my fan.
I think the cpt is for a start kit 4.9. All right this blue goes here. My two yellows
go here. One of those is from the contactor and one of those goes to the
is run for the condenser fan motor. All right I'm gonna leave that right there.
Y'all forgive me. That probably just failed. I have had that happens to be a very common failure
with those disconnects. All right so I have zero volts across here but when I test to ground I have
120. That tells me I have only one leg supplied which means that just failed.
Um looks like 2011 so 15 years old. All right so I'm going to show you if I can.
Right here I should have 240 volts. 247 so when that is on I should have 247 and I've got 5.6
and I'm going to show you here's ground right here. I have 120 on that one and I'm going to
have 120 on that one. It is feeding through the equipment and bring it so one of these legs of
power this side right here is not working. This is clearly a motor I did not replace.
It does not look that old.
Bearings turn freely. Let's see what this says. That is a quarter horsepower 28230
1.82 amps and five microfarad capacitor. Okay this right here
tells me the fan motor is a one-tenth horsepower 0.8 amps. That does not mean
that that is that will not work but that motor did sound awfully rough like it was
having trouble. I got to replace that just to finish diagnosing this motor. I should probably
add I have been here before and I gave them an estimate to fix it the last time I was here
and they used somebody else and here we are the next year and it's broken again.
The customer did ask for an estimate to replace the system so I'm going to give them an estimate
for this and possibly a new motor. Remount the thermostat and not thermostat the capacitor
just to see if it's going to get get up and cooling.
We will see approval to replace this breaker. It's not really a breaker it's just a
rated disconnect. I'm actually using another disconnect for them that comes with one of
these and I needed to put a breaker in it so I pulled this out so it's a good chance to use it.
I gotta be careful my fingers are very close to hot electricity. Now this is rated at 60 amps but
it is not technically a breaker. Downing is off to turn this on. There are a couple of things I
want to check real quick before it sounds like that motor might go out like two amps. I am pulling
four amps on that motor. I'm not feeling the suction line getting cold. Trying to
hurry and check this before the motor goes out. 251 and 87. I said this was a 2011.
I just want to make sure. Field charged R22. There actually aren't very many of those
so if this is an R22 system those pressures ain't that bad but that is probably the wrong motor for
this. Okay right when I cut off the camera a second ago condenser fan motor stopped. Somebody's
calling me from Saskatchewan, Canada. That's gonna be a long trip. Okay I am thinking that possibly
that was supposed to be a 825 rpm motor and they put a 1075 on it. I'm about to find out. Hey Eric
I have a question for you. I have an ICP condenser and I need to know what the proper size condenser
fan motor that goes on this thing please. Let me know when you're ready. All right serial number
is X112966338. This is let me see model number is WGH or maybe it's CH3302GKR4. I think I have a
part number. I think I have a part number on the motor. Part number 1185923.
So it's 1100 rpms is that correct?
I got approval to change the motor with what I told them. I think I would do the same thing.
That contactor is kind of burnt. I gave them an estimate on that when I was here
about a year ago. Did not get it. Okay y'all see this. I would really like to know if they got that
correct. This right here. Technically this one and this one are the same thing but if they were
going to do this I would have tied all three of these together. This is my run winding and
technically this is the same thing. You have two browns one with a white stripe so in case you want
to use an independent capacitor. My final piece is slightly boogered up. I have an idea. I'll be
I've really boogered it up now. I don't know if that thing is ever coming out.
Okay honestly I do not know the name of this kit. That kit right there. Keep that.
Holes are open. This is going to be on the bottom. Plugs are in the top.
Forgive me. I need to get this other one started. There we go. There we go. Okay before I can
use this. That is a little bit boogered up right there. I'm gonna have to drill it out.
You need a half inch drill bit to do what I'm doing. I'm gonna take this out here. Okay
to cut these off. Okay we want this to turn counterclockwise shaft end. This way right here.
So that means clockwise lead end. Clockwise rotation lead end. Yellow to orange and orange
to yellow. So we have to reverse our rotation. Most motors come counterclockwise lead end.
By lead end these wires are our leads. So shaft end lead end. I want to see out here.
Okay the hole for my wires is right next to one of those.
Wires down there are not long enough.
It's pulled through so we're ready. White and brown with the white stripe are the same thing
basically. They both are the run winding. I think that's going to make it. Oh no my brown wire has
gone back inside. I gotta. Okay I'll reach around where I can't see. Okay that I can deal with.
Brown goes to the two terminals and it only needs to come this far. So let's cut it. Let's
give it a little bit of extra. And my phone is really ringing constantly. All right this
is my run and we can take it up here to where our run from the contactor plugs into the capacitor.
And this is our common start run and common. Common goes to the defrost control board
because sometimes the board shuts off the condenser fan motor when it's
going through defrost. Blue comes over here to home and this yellow right there goes to the
contactor. So we're going to put it over here on seat. It's actually the run winding but it is
common for the capacitor. Y'all forgive me. I'm almost OCD about this. I want it to look good so
that I just want it to look good. That's all. All right we need to screw down the fan shroud
and we'll be done. If I'm not mistaken that motor is rated at 1.5 amps. Let's turn power on.
It is turning in the right direction. 1.12. I do hope you enjoyed the video.
That one was a little bit challenging but we got her done. If y'all like the videos give me a thumbs
up. Subscribe. Check out the store in the corner. There are some links in the description for stuff
that I use. And for example I install ACIQ equipment the vast majority of the time. If
y'all want to be an ACIQ dealer there's a link in the description. And I'm using Jobber. I really
like it. Like the estimate I did for the customer today. Worked it up right there on my phone.
Walked in and said hey it's gonna be this much. I gotta replace a motor disconnect. I got approval
right away and they paid me right away. Yeah it's got tap to pay. I can use that on my phone. That
was pretty nice. So um if y'all are interested there's a link in the description for that too.