In today's video, I visited a mobile home that had multiple problems, airflow problems, or problem with the wrong door being on the air handler and when I got outside, there were visibly problems with the compressor. In fact it wasn't pumping at all. Stay tuned. I think you'll find this interesting.
#hvac#hvacguy#airconditioning#airconditioner @ACIQComfort @BlueCollarWarrior @MilwaukeeTool @KoolinwithKrauss @Onemanhvac 00:00 Introduction 01:06 Inspection Inside 03:30 Checking Condenser 04:37 Compressor Don't Look Right 06:01 Pulling Plug On Compressor 09:12 Checkin For Pressure 09:45 Ohming Compressor 12:11 Listening And Checking Amp Draw 13:33 Not Pumping 14:19 Ending
Hey guys, I just had to drive all the way across town to come back to this address
Because I left something here
I was here yesterday and y'all ain't gonna have to believe what I found
This one I was basically able to diagnose just by looking at it stay tuned
Knock knock. Hey y'all come check on this air conditioner. Yeah, man if I come in see what's going on
All right, I'm gonna I need to get right where you are
65 degrees in here
Sounds like it's sucking air
All right, that's completely closed off
Why are they closed?
Oh my first of all, that is the wrong door
for
this air handler
Do you not feel like getting cold?
That's not bad at all
Y'all hold on and this right here
tells me
This is not good that does not feel
cold
I'm gonna go ahead and turn this off
If they have all the vents, um
blocked off
That should be freezing up and it's not even cold
They got multiple problems be right back. Yes, that looks very dirty. But um
This over here actually looks like it's been washed I am looking for
Let me make sure we ain't got no power I got this pulled out
I don't know if y'all see this but um
It looks like some melted plastic
I was looking for
possible signs of a leak like oil spots
That right there does not look good. Like it might not have been making a good connection or something
Y'all hold on a sec
Y'all might hear in the background
What sounds like a turbine?
It happens to be the time of year when they're
putting insecticide in um
Uh pecan grove back here
and uh
It's a great big turbine that they're using
And if one comes by i'll try to show it to you
Okay, not only is it not making a good connection. It has melted itself in here
I'll show you something else
You see the discoloration of this label this compressor has been getting hot hot hot hot
Probably because it's been running with no refrigerant if I take this out it might never go back in
Look at that
This compressor was running
absolutely horrible
That might be where we've lost our refrigerant i'm gonna go get some nitrogen pump it up and see if we don't
Hear anything. Okay contactor is pulled in
it does look like our
Switches are all still intact. So it must have refrigerant in it
Oh, no, this is this one's kind of strange whatever's going on it um
Definitely was not
really pumping
To help produce cold air
This might have a little bit of pressure in it
Wow, it does have refrigerant in it
i'm reading
194 psi
194 i'm just hooked up to the low side
Just from observation I would say that compressor's cooked
but let's
Let's do some homing out and maybe i'll be able to show you
Although I believe what was happening was mechanical
I might plug it up and
Let's see
Just listen to it for a second first. I'm gonna expect that something mechanical is happening to it
What I mean is that the actual pieces that pump
there might be something broken in there and it's
Physically not working correctly
I'm going to guess this is common
I got two
point four ohms
2.5
three
point
I'm, sorry, that was all over the place. Let's just say 2.8. My total should have been more like um
Three or four
But I was getting four something
It is not perfect
single phase compressor like this
It still might work
Man that is absolutely horrible
Okay
We're gonna plug this thing. We're gonna put the disconnect back in
And listen to it. I'm gonna leave you mounted right here
All right, here we go
I'm gonna go ahead and hook up gauges to it just to show that it is not pumping
Plug up
Make sure these are valved off and listen again
It's not pumping at all
96 196 and 194
All of that stuff in combination tells me this compressor is cooked it has
An internal what I have called mechanical failure
or a physical
failure with the shaft, um
The actual scroll compressor something
Is wrong on the inside of this compressor
Honestly, I would kind of like to tear it apart and take a look
And they got multiple problems inside all the vents are closed. They got the wrong door on the air handler. So
And this is probably a 410 system
Let me see we have a two and a half ton
R410 system
I think it's time for a new system
I mean a new compressor a cleaning
Doing something with that door. I have tried to find those doors before and
They're very hard to find
Um do something to close off that door
One time I had to actually beat the louvers closed with a three pound hammer
um
It's got to do something to close that opening
Normally the disconnect goes in this way to turn it off and not lose this pull out you turn it upside down
So it's turned off for the next person even if it's not me
The disconnect will still be there
I do hope you enjoyed that video
I dropped an estimate for a new aciq
actually a heat pump and
coil
That that would be a great addition for that house, um or that mobile home
And it doesn't cost me much more than just a straight cool
And honestly in georgia the code is you got to have electric heat cannot be the primary source of heat
So that's what I dropped an estimate for
And if y'all want to be an aciq dealer
There's a link in the description
If you enjoy videos like this, please like and subscribe. It does help out
I am here with my buddy
Riley i'll see y'all tomorrow