If you’re interested in more business related videos I’m starting to publish them for members. In time I plan on have a full selection on how to manage and complete every step of opening and running a business! Join this channel https://www.youtube.com/channel/UCiz21FXLOV65NTgiUfJsxTg/join
In today's video, I take you along on a service call where the customer told me that his system had frozen up a couple days before I got there. I checked everything out. I cleaned up his system and washed the coils, cleaned the blower wheel and still there was a suspicion that maybe the blower had stopped. So I'll check to see if the ECM motor was under warranty and it was customer approved the labor to replace the motor under warranty came back and replaced the motor. System is doing fine at this time and hopefully it won't freeze up again. #hvac#hvacguy#airconditioning#airconditioner @Jobber @ACIQComfort @KoolinwithKrauss @HVACRSurvival
AI Generated·May contain errors
Video Summary
AI Generated
The technician diagnoses and repairs an HVAC system that previously froze up. After identifying high head pressure and low superheat, the technician cleans the coils and blower wheel. Although the system is currently running, the blower motor is replaced under warranty as a predictive maintenance measure to prevent future failures.
Hey guys. I've been gone for a couple days. I went to go see family up in South Carolina. Yes,
I am in the deep south. We consider South Carolina to the north. And while I was gone,
something happened. This. I'll try to stick a photo right there. So, I want to thank all of
you for your support. What I started as a method of teaching, what little bit I know has grown into
a community that I fully enjoy. The video I have for you today. So, thank you. Thank you
very much. The video I have for you today, the customer called and said it froze up over the
weekend. So, I just fixed everything I could find and I'll take you along with me. It's
hard to fix something when everything's working. The good part is this one was under warranty.
Stay tuned. Okay. This customer was complaining that the other day he
came out, heard it kind of humming and saw ice around the compressor. So, today
we're going to check things, look at the evaporator core. I am most interested in
the blower motor because it's working now and has been for several days.
That head pressure looks mighty high. That does not look that bad, but that head pressure is high.
We have an X13 motor. I'm checking the bearings, trying to wobble them back and forth.
Right now, I'm just wanting to look at the speed taps on the blower motor.
There's another one right here somewhere. Okay. Maybe y'all can see that. I'm also looking to
see if there's anything in the blower wheel. That actually looks like my blower tap was on number
two. Let's see what happens if we move it over to number four. That blower wheel is kind of dirty.
There's a chance we're going to have to replace this. So, if we do, we are definitely going to
clean that blower wheel. All right. Dude, compressor just came on and my blower did not.
Still not coming on. I'm actually moving my speed tap. There we go. We got a little turn in now.
My phone got a little bit hot. That head pressure is high, too high, and it seems to be fluctuating.
I think we got something else going on. It may not be the blower motor.
You'll see how rapidly that head pressure is changing.
I'm going to see if I can measure superheat and sub-cooling through this right here.
I was doing that to measure temperature out here. Right now, I'm at 99 degrees in the sun.
Reason I'm checking superheat and sub-cool because I'm beginning to suspect
that we might have a problem with that TXB.
That could give me high head pressure like that. I'm going to find my food ablators right there.
That's on the condenser. It's super hot, and this can serve as my...
How does that remove that?
I need to be able to wiggle it a little bit so it makes a good contact.
Let's put this back on.
You don't have to do that. That is not necessary. No, no, no, no.
Customer setting up like a little tent for me.
17 degrees sub-cooling, 2016.
My superheat is low, and my head pressure is high.
A high sub-cooling, low superheat.
I'll be honest right now. I think I need to give it a thorough cleaning,
even though it may not look like it needs it.
What do you say we do that? We give it a thorough cleaning, maybe even that blower wheel.
Y'all see this? Thank you.
I think that's what our next step is. We got to ensure that that coil is clean,
this one's clean, and maybe the blower wheel, and start from scratch.
I think I just need to clean it to make sure that everything's clean,
and then come back and measure again. Is that okay with you?
Oh, is that a holly bush behind me? Oh, yeah. I trimmed it up this morning.
I didn't trim it up enough, did I? I'm convinced people put those there
just to torture us. Actually, it is kind of dirty over here,
and there's a section back there that you got to take the panel off to clean.
A dirty coil is not going to cause it to ice up, but it will give me that high head pressure.
I'm going to go ahead and rinse off the evaporator coil,
because I'm going to put chemicals on both of them. All right, let's get some chemicals ready.
I forgot to add water first.
Ooh, that's a lot of foam. We can put that back together.
Okay, these are my pressures with clean condenser, clean evaporator, much cleaner blower wheel.
I still seem to have a low superheat. It's coming up, though, fluctuating.
I'm going to watch this for a second, and I'll bring you back.
Well, basically, my head pressure has come down on average about 20, 25 psi.
My superheat is still low, but with that OEM blower, I cannot increase the speed.
None of the other speed taps work. Subcooling is a little bit low.
It might be because it's close to 100 degrees, but my superheat,
that is just a little bit worrisome. Let's go in and check on, last thing, check our filter.
That's fine. That's fine. That's all I need to see.
Whenever it's going, you know.
Let's see how it sucks in. This is one I was having trouble with the other day,
and we kind of narrowed it down to possibly the blower motor may have stopped.
There was no other reason for that thing to have iced up.
So, as a preventive measure, the customer agreed to replace the blower motor.
So, that's what we're going to do. My batteries did.
I had this thing turned up to three, and this customer was really looking out for me
with this tent thing up here. He had it out here the first time I was out here,
and it was about 100 degrees, and I was probably out here two and a half, three hours.
In here is what we are replacing. There are some wires down here that are a little hard to get to.
Try to disconnect them.
Holy spokes. That is my ground wire. I don't want to completely disconnect it.
You didn't have to put up this tarp for me.
Man, I figured it out as it was. I came out here. I just drove to town
to pick up a set of heads from the machine shop. I like to die.
I can at least get him out of the sun for a minute.
Well, I greatly appreciate it.
That sun is relentless.
You haven't had any problems since we were out here.
I turned it. We went out of town this weekend. I turned it up to
like 76, and we left town. I came back home, put it back on 74, and it's worked fine.
I've been keeping it now.
When I first turned it back down to 74, I walked out here and looked. It didn't seem to have frozen.
Well, that is good.
I guess that motor just quit. I mean, that must have just quit and then started back.
It's very possible those motors are finished.
If it's anything like a car, if it quit once, it'll quit again.
Yep, I agree with you.
They don't heal.
The reason we went ahead and offered to replace this motor is because it's under warranty.
And from everything we could find, it's the only thing that could have caused it to ice off.
So, he's about to get a new motor.
This is not preemptive maintenance.
This is predictive maintenance.
Basically, if it did it once, they might do it again.
The customer knows he was there with me the whole time, and he approved it.
I felt that move. That's just a little tight, though.
I'm going to walk the ceiling and floor.
Except you're a diesel mechanic.
Yes, sir.
Ain't no denying who your dad is.
Already filthy from an earlier job.
I tried to clean this off with a brush the first time I was out here.
And actually, when it's dry, you can do some good with a brush.
Those blades are sharp.
I know I'm making a mess.
We're about to find out if they sent me the right motor.
It's kind of right in the middle.
We want our, if we can manage that, a very different looking motor.
Let's make sure it matches up, though.
Half horsepower, 4.1 amps, 208, 230, 1050.
Okay, half horsepower, 208, 230, amp, 3.9, 4.2, RPM, 1050.
That can stick out and hit my panel.
I got to be really careful.
You're cleaning without the motor in there.
A lot easier, yeah.
Do a better job.
All right, over tighten it.
I'm going to go ahead and hook this one up.
It is the first.
Nope.
If y'all can see here, I'm going to have common line voltage,
ground, line voltage, and then my speed taps are right here.
I only have one wire and it was hooked up to two, I believe.
Almost ready to install.
Make sure that's right in the middle.
Try to make sure you put your, hold on just a second.
Make sure you put your set screw on the flat part.
If you don't, those little grooves that the set screw cuts into the shaft
will make it impossible to get it off.
I'm just tightening up that screw.
Let's go reinstall.
I'm going to plug in my wires first.
Okay, on these systems, common is brown.
All of these spade connectors that are low voltage,
all of these for your speed taps and this common are a regular spade connector size.
These others for ground, line voltage, and neutral are a smaller size.
I'm going to put this on too because I think that's my 24 volt call.
And these, it doesn't really matter if that one goes there or this one goes here
because it's 240 volts.
But if that were 120 volts, you would want your neutral going right there.
I'm leaking.
I'm going to need my extension.
Get in there.
Okay, let's hope that this bad boy will come on and start turning.
If we're lucky, we might be able to adjust the fan speed.
Let's come on.
Condenser fan motor just started.
We're good.
I do hope you enjoyed that video.
One thing I didn't show in this is like a little bit of refrigerant escapes
while we were buttoning this one up on the first visit.
So we adjusted the freon and that thing, some super heat and sub cooling and doing good.
That job turned out real good.
Replacing the motor was just a preventive measure because
we had evidence that possibly it had stopped.
I hope you enjoy the video.
Riley wants to go in because it's hot.
Catch you on the next one.