If you’re interested in more business related videos I’m starting to publish them for members. In time I plan on have a full selection on how to manage and complete every step of opening and running a business! Join this channel https://www.youtube.com/channel/UCiz21FXLOV65NTgiUfJsxTg/join
In today's video I visited customer who requested a preventative maintenance. During this preventive maintenance I found that one of the systems was slightly low on refrigerant. So I decided to do a leak search and I found what it looks like a large leak. None of that is abnormal. But the price I was quoted for a replacement coil is abnormal and I discuss what I feel about it. #hvac#hvacguy#airconditioning#airconditioner @ACIQComfort @Jobber @yessimoli4263 @KoolinwithKrauss @MilwaukeeTool
Hey guys in the video I have for you today I was actually at this address doing a preventive
maintenance. Those have started to take a really long time for me. Two systems took me two and a
half hours. I'm just being more thorough and on one of them I found that it was just slightly low
on refrigerant. It's a new home for this couple and they just wanted a preventive maintenance so
the news that I gave them it was slightly low on refrigerant was not good news. Stay tuned I'll
bring you in right at the leak search and at the end I'm going to discuss something that is just
insane. Stay tuned. I'm doing a PM to do a leak search and I wanted y'all to see
where the plumbers where the plumbers decided to place their vent right here right in the middle
of the walkway. During the summer if you got to work in these attics try to do it early in the
morning. When I do these PM's first thing I tackle is the attic. I try to do a thorough PM.
They have two systems here and I've already been here over two hours. I found this one
just a little bit low on refrigerant so as usual I suspect this evaporator cool.
14 year old system. Pretty good chance. So let me fire this thing up. Kill the beeper.
I'll bring you right back. Fire it up on medium. I'm gonna put that on high. First thing I'm gonna
do is go to my number one spot right down here in this corner. That's pretty good. That's pretty
good. All right I think I may have gotten some water in the tip. Every time you'll hear that
going off it is like bumping up against something. Normally what I do is just kind of cruise along
at a decent speed with my leak detector until I start seeing a reason to slow down.
And in this area I've gotten enough random hits to slow down.
Like a lot of leak detectors it adjusts to it adjusts its own sensitivity.
So if you leave it in the ambient of refrigerant it will adjust its sensitivity. So I
pull the tip out here in what should be fresh air for about 10 seconds and go back.
It was going off every 10 seconds a little while ago. All by itself. Now the cat's got its tongue.
I'm dragging along the bottom here. This is one of those cases where you're probably
it is probably leaking. But if I ain't finding a leak I'm not fixing to condemn it.
You gotta be careful dragging along the bottom on the inside because there's water in that drain pan
and it'll mess it up. Okay I know I know. I know.
Ah the hit that I just got went all the way up here. Let's see if I can show that.
Man I just got a two bar hit right there.
Oops I just put myself in the dark. There's a mode button on this thing somewhere.
There we go. All right I keep trying to show you these bars.
That's three bars right there. I'm glad I double checked because I had half a
something here. Another bar. Leave this alone for just a second.
All right I didn't have the bars go all the way up again but that's enough for me to
say that this is leaking. Blower motor. The blower wheel was also very dirty
and it needed a capacitor. All things I found during preventive maintenance.
Problem with this one is the age. Might not be advisable to repair it.
Serial number 4212. So it's 14 years old. I'm not sure. If it were mine I might repair it
but I'm the kind of person that can fix this blower motor if it fails.
It does have an ECM blower motor so the repair for a blower motor or a condenser fan motor
after the evaporator cool is not too much for me. It might be a lot for somebody else. So
I'll try to show you this model in serial. Don't forgive me if it's sideways. 4212 one and a half
ton. 5 kw. Well guys I gave this customer. I am working a estimate right now in Jobber.
Y'all can see right here. I'm working up my estimate to replace the evaporator coil,
clean the blower wheel, and replace the capacitor. And my carrier distributor here in town
wants $1,100 for a one and a half ton 14 year old R410 evaporator coil. It is obvious they don't
want to sell the coil. They want to sell a new air handler. I'm going to reach out to Johnstone. I can
probably get a cheaper price but that is crazy. Crazy. If y'all like the video please like and
subscribe. That really does help out the channel. Check out the store in the corner. Maybe check out
the links in the description. I just said I'm using Jobber. If y'all want to try out Jobber
there's a link in the description. And I'll catch y'all in the next one.