In today's video, I visit a mobile home that had no air conditioning. I turned on the system in the indoor air handler came on and started blowing, but there was no cooling at all. When I walked outside, the condenser was not running. After taking off the panel, I quickly realized that there was a tiny little bug underneath the contacts keeping the system from running. I replace the contactor and start system up, showing exactly how to do this repair. I hope you enjoy. #hvac#hvacguy#airconditioning#airconditioner @ACIQComfort @Jobber @MilwaukeeTool @BlueCollarWarrior @KoolinwithKrauss @HVACRSurvival @yessimoli4263
Hey guys, today's one of the first days I'm able to get home at a decent time in a little while.
It's been rather warm. Y'all see Raleigh? Hey, get out that hole. Yeah, I'm talking to you.
Don't look around. I'm gonna get you. Hey, get out that hole. This is a little game we play.
He'll get the zoomies in a minute. The video I have for you today is about a bug. Stay tuned.
See these little bugs flying around like right there. Dems, them Zika mosquitoes down here in
South Georgia. I'm kidding. Those are love bugs and it is the season. I do not know if somebody
is home. I do have a key. I also saw some wasp up here, so I need to be careful. They need some
shrimp right here. Yeah, these little things here. That's a love bug. They call them love
bugs because when they're mating, their tails stick together and they fly around like that.
The keys here. Hmm, that one don't work. That one don't work. There's a chance. Oh, there we go.
Knock, knock. Hello. Maintenance. Climate control. I think we're in the right place.
This is just a big fan. Putting this on full. I see it's following a schedule. We may have to
remove that. Let's see if we can get this to come on. Hmm. Blower's coming on. This looks like one
I have recently cleaned. My filter right now. I'm gonna put this door on. I didn't feel it getting
cold, so let's step outside. Huh, it looks like I walked around the wrong end. Okay,
I think I can hear the contactor buzzing. Let's see what's going on.
I think I see the problem already. Y'all hold on just a second. If y'all do not see that,
I'm gonna get a light right underneath that contact right there. I hope y'all can see that.
There is something sticking out that looks like a bug tail. There's something underneath the contact.
That's our problem. I'm gonna show you how to prove it with a meter. Meter on. First of all,
let's check right here. We are getting 27.5 volts. I hope you can see that. If not, it's 27.5.
And down here, I got 246. So when I got 24 volts on this, that 246 should transfer to up here.
And it don't. Obviously, this has no break in it. So my problem is right there where I showed you
that bug. Let's make sure we don't have power. Come here to ground. Nothing. Let's change this
thing out. Now some of you have asked why it still buzzes when there's no electricity.
Right here, it's because this wire and this wire have a 24 volt potential and it's pulling in
a contactor right here. So one of these wires are hot. One of them is hot. That's 24 volts.
It's very likely that the transformer is grounded, which means the other side is like a ground.
But I'm going to treat them both like they're hot right now. The reason I'm treating them
both like they're hot is because when it's straight cool like this, it don't matter which
side is hot and which side is common. So it's very, very frequent. We find that the one that
we think is common is the hot. So I'm just going to treat them both like they're hot.
And it's just 24 volts. It's kind of like,
it gives you the same feeling as like a nine volt battery on your tongue.
Not that any of us have ever done that. It ain't going to hurt you, but it'll make you jump.
You know what? But I isolate it because I don't want to burn a transformer or a
fuse while I'm changing this. Okay. Our common, the black was on the unbroken side and the run,
you hear that bug still stuck in there. And the run was on the side with a break in it.
We can do it either way. It's straight cool. It don't have a crankcase heater.
You could use a two pole contactor. It don't really matter.
I don't always take all the wires out first. If you're not, if you're not very familiar,
there's the little bug. Hold on just a second. He's about to fall out. I'm still going to replace
this. If y'all can see down in there. All right, there goes the little bug. It just fell out.
I'm still going to replace it for multiple reasons. When it doesn't make a good connection,
it can get hot and you can see where the metal was a little bit discolored
and the bug, I don't know how to describe it other than it kind of caramelizes
underneath the potential electricity. And it coats the contacts,
which means it's possible. You'll have a problem in the future. Even if you do just take out the
bug. We'll do low voltage in a minute. Let's get ready and do our high voltage. Hold that in there
and snug it up. I might have a video coming that I did yesterday where I, that's not out far enough,
where I used a contactor that was very cheaply made. And when I tried to tighten up one of these
lows, the whole thing just broke apart. Okay. Those are in there. What do you say we go ahead
and hook up our low voltage? This one is for my condenser fan motor. And this one is for the
capacitor, which feeds my run for, excuse me, feeds the run for the condenser fan motor. These
two are for the compressor. I'm going to cut off the end and put them under that lug instead of
plugging them up to this baby connector. It just makes a more secure connection.
I exclusively buy the 40 amp contactors now because they have these lugs and they're just
rated for 40 amps, which means it's a more sturdy contactor. Do the same thing with this one.
And I know some of you are curious as to why this condenser is on a stand like this.
No, it's not because we're in a flood zone. Although we might be.
It's so they can transport the mobile home with an air conditioner already installed.
Let's make sure everything's right. Let's put some power to it.
Can y'all see where that contactor got hot where the boat was? I'm going to give you an overhead
view so you can maybe see it better. You see the discoloration? That's why I go ahead and
change contactors even if there's ants or something in them and I can brush them out.
Just go ahead and change it. Last step is to check pressures.
We'll change filter, check pressure, put in a filter because there is not one.
I can see that line sweating, so I know we're doing at least okay.
You see right there that this ant is trying to run away with was the reason that air conditioner
was not working. Kind of looks like one of them earwigs or something like that. That's all it
takes. Just got the filter put in. A 20 by 20 filter fits in that door. You just kind of have
make it fit in the door. That's really the only way to filter that system.
If I can get this to pull up I'll show you my pressures. It's hot in there. That head pressure
just a little bit elevated but the suction has pushed that high suction pressure. Forgive me,
this is not the correct refrigerant. There we go. That high suction is pushing up the head pressure
that will come down. We can take a look at this coil. If y'all can see in there it is not
absolutely filthy. So I'm going to leave it like this. I do hope you enjoyed the video
and if bugs, frogs, lizards, stuff like that causes problems for you, leave a comment.
If you would, check out the store in the corner if you want to be an ACIQ dealer.
Check out the link in the description and I've been using Jobber. I really like it. It lets me
add pictures to my estimates of what I'm proposing to install for my customer and I like that. So if
you want to use Jobber, check out the link in the description. Catch you on the next one.