Shoyan documents the air tightness testing and insulation process during the sheathing stage of a home build. The video covers the installation of studs and braces, the results of the C-value leakage test, the preparation of backing for cellulose insulation, and the installation of the wood-fiber insulation, highlighting its superior sound-absorption qualities.
Hello, Shoyan here. Today, I'm having the air tightness test done at the sheathing stage.
Along with that test, there are some other things to get through. I'll set the studs and
secure the hardware, then the insulation crew will handle the cellulose. I'll also add the
blocking in the corners and other little jobs like that. First, I work on the studs and diagonal
braces, then secure the hardware. On modern houses like this, the studs and columns around
the perimeter stand on the sill. But inside the house, I can't put in a single stud or brace
until the subfloor is down. The studs are already cut to stand on the subfloor,
measured from its top. The braces are cut to length too, so even if I'm worried about the
strength before the subfloor is down, I can't put them in yet. On some jobs, the subfloor is down
before framing day. In that case, we can set the studs and braces as the frame goes up. The way I
do it, we frame, have the plumber run the pipes, lay the subfloor, and then set the studs and braces,
so the braces go in pretty late. But the sheathing is on good and tight, so it won't lean even in a
strong wind.
First, I set the studs, then fit the braces into the notches.
These are pre-cut, so they come out perfect and drop right in. If the house were standing out
of plum, one of the braces would come out too long. But I checked for plum, so the braces
fit perfectly. If they don't fit, that tells me the house is leaning. Then I secure the hardware
for the braces and columns. Each piece of hardware has exactly one job, so the number I need depends
on what has to be held in that spot. If I only think about the brace hardware when securing it,
the column hardware can end up in the way. So where two or three pieces land in the same spot,
laying out how they sit against each other and putting them on one at a time is what matters.
Now we'll have the airtight test. At this stage, the sheathing is on outside.
Inside, the foundation insulation and floor insulation are in,
and the subfloor is down. Those are the conditions we're testing under.
They ran the first round, and the C value, the equivalent leakage area, came out at 0.5.
I wanted to be under 0.5 with just the sheathing on, so that number wasn't what I was hoping for.
So then we went hunting for gaps. And it turned out, the entry door wasn't shut all the way.
This door has tight weather stripping, so even when I think I've closed it,
if it doesn't click shut, it isn't sealed. Pulling that door until it clicked,
dropped the C value by 0.3 down to 0.2.
The air sealing is still to come. Once that's finished,
I think the number will be much closer to 0.0.
With the test done, next is prepping for the insulation.
This time, it's the type where they staple up a sheet and pack cellulose in behind it.
That needs backing. The walls already have studs, so I just fasten it at the corners.
For the ceiling, the crew puts up a sheet to keep the insulation from falling down,
but there's nothing up there to fasten that sheet to.
So I run the backing at 450mm intervals.
On the ceiling, the insulation is 30cm, which is quite thick,
but one of the crew told me on his way out that it doesn't weigh all that much.
I've never had cellulose put in on one of my own jobs, so I have no idea how heavy it ends up being.
Anyway, I ran the backing at 450mm intervals and hung it every 900mm.
He said that's plenty, but honestly, until I see it going in, I can't help worrying.
It's a sloped ceiling.
After the insulation goes in, the ceiling gets finished on that same slope.
That backing doubles as the ceiling framing. I make sure it goes in right.
If it were only holding insulation, a little unevenness wouldn't matter,
as long as the cellulose stayed put.
Here, the ceiling line drops 30cm, and the insulation will be packed in right up to it.
Once they staple the sheet on, that backing gets pulled out of line.
Later, I run another layer of support backing underneath,
but that second layer just follows the first one.
If the first layer is off, it stays that way, so I get the first layer perfectly straight.
The insulation crew came in and started with the sheet.
This sheet, or non-woven fabric, whatever it's called, lets air pass through.
He puts it up beautifully.
I'm going to hang the airtight membrane the same way after this,
so I was learning his technique, or maybe stealing it is the better word.
I doubt I can get it up as neatly as that.
Watching someone else work and stealing their methods or learning them
doesn't bother anybody, and it's free, so there's no way I'm not going to watch.
While I was at it, I got to see them blow the cellulose in.
Cellulose is wood fiber.
Newspaper, cardboard, wood chips.
This is the last job wood fiber ever does.
Somebody thought that through well.
It gets packed in between the sheets by feel.
This insulation doesn't harden in there.
It doesn't cure like urethane, but at the right density, it settles into a solid mass.
Fiberglass always leaves me itching when I touch it, but this insulation doesn't itch at all.
But it gives off a kind of paper dust, and the air got stuffy.
The wall, well, the pillars are 120, so 120.
This is like compressing the cellulose newspaper, mixing it with something, and blowing it in.
So this is wood fiber, or cellulose?
Cellulose.
This is fiber, fiber, jet fiber, super jet fiber.
This is the name of the mold, isn't it?
I don't really get it.
The good thing about this is, of course, the insulation, but the sound is amazing.
It absorbs the sound.
That's why I put the iron plate on the ceiling.
Normally, I'd put a C-shaped board on it so it wouldn't make a sound, but I don't do that anymore.
It doesn't make a sound.
But can't you tell that it's not echoing when you're talking?
It's not echoing at all.
No, it's not echoing at all.
What do you think?
No, it's pretty amazing.
This is just a window, but...
It's really like a music room.
No, you can't tell when you come in and talk.
It's a little creepy because the sound bounces back.
If I put a board on it again, the sound of this will come out a little.
If you run away to the outside, the sound from the outside will not be transmitted.
That's why I'm looking forward to the sound of the rain when I shake this iron plate.
Thanks for watching.