Review where endotracheal tubes, umbilical venous catheters and umbilical arterial catheters should end up on neonatal X-rays. Where are they when they're too deep or just in the WRONG place!? Learn the basic essential anatomy you need to know!
---------------------------------------------------------------------
Please be sure to give us a like, comment about future topics, and subscribe to this channel to stay up to date on all things NICU! Also, click the notification bell after you subscribe to gain your weekly NICU knowledge as soon as it's loaded!
---------------------------------------------------------------------
Dr. Tala is a board-certified neonatologist and has worked in busy level III and IV units for the past 15 years. She has won multiple teaching awards throughout her time as a neonatologist.
----------------------------------------------------------------------
References:
Congedi S, Savio F, Auciello M, Salvadori S, Nardo D, Bonadies L. Sonographic Evaluation of the Endotracheal Tube Position in the Neonatal Population: A Comprehensive Review and Meta-Analysis. Front Pediatr. 2022 Jun 2;10:886450. doi: 10.3389/fped.2022.886450. PMID: 35722478; PMCID: PMC9201277.
Rubortone SA, Costa S, Perri A, D'Andrea V, Vento G, Barone G. Real-time ultrasound for tip location of umbilical venous catheter in neonates: a pre/post intervention study. Ital J Pediatr. 2021 Mar 18;47(1):68. doi: 10.1186/s13052-021-01014-7. PMID: 33736669; PMCID: PMC7977571.
Tang CHM, Seah JCY, Ahmad HK, Milne MR, Wardman JB, Buchlak QD, Esmaili N, Lambert JF, Jones CM. Analysis of Line and Tube Detection Performance of a Chest X-ray Deep Learning Model to Evaluate Hidden Stratification. Diagnostics (Basel). 2023 Jul 9;13(14):2317. doi: 10.3390/diagnostics13142317. PMID: 37510062; PMCID: PMC10378683.
Peterson, J., Johnson, N., Deakins, K. et al. Accuracy of the 7-8-9 Rule for endotracheal tube placement in the neonate. J Perinatol 26, 333–336 (2006). https://doi.org/10.1038/sj.jp.7211503
Paudel, Krishna Prasad et al. “Accuracy of 7-8-9 Rule for Endotracheal Tube Placement in Nepalese Neonates.” Journal of Nepal Paediatric Society 31 (2011): 175-179.
NRP 8th edition
Liu, Hsien-Kuan, Yung-Ning Yang, Shu-Leei Tey, Pei-Ling Wu, San-Nan Yang, and Chien-Yi Wu. 2021. "Weight Is More Accurate than Gestational Age When Estimating the Optimal Endotracheal Tube Depth in Neonates" Children 8, no. 5: 324. https://doi.org/10.3390/children8050324
West J Emerg Med. 2015 Jul; 16(4): 575–576.
Published online 2015 Jun 17. doi: 10.5811/westjem.2015.4.25821
https://pediatricimaging.org/diseases/endotracheal-tube-malfunction/
https://starship.org.nz/health-professionals/umbilical-catheters-in-the-neonate/
Ahmed, Aadil. (2015). Where's the line/tube?. South African Journal of Radiology. 19. 10.4102/sajr.v19i2.888.
https://radiologyassistant.nl/pediatrics/abdominal-masses/lines-and-tubes-in-neonates
Al-Dajani N, Osiovich H, Smyth J, Byrne A, Jamieson D, Kaczala G. Umbilical Venous Catheter Position: The Value of Acquiring a Lateral in Addition to a Frontal Chest Radiograph. Cureus. 2023 Oct 7;15(10):e46642. doi: 10.7759/cureus.46642. PMID: 37808595; PMCID: PMC10560078.
https://ashfordstpeters.net/Guidelines_Neonatal/UAC%20Oct%202019
https://pediatricimaging.org/diseases/umbilical-arterial-catheter-malfunction/
----------------------------------------------------------------------------
***TIMESTAMPS***
00:35 The future of using AI
1:00 Ideal position of ETT In neonates
02:51 ETT calculation depth
03:40 Continued ETT position
09:36 Ideal position of UVC
16:24 Ideal position of UAC
19:15 Quiz questions
----------------------------------------------------------------------------
*Disclaimer*: This video is intended for educational purposes only and while we strive to give the most accurate information, errors may occur. Subsequently, this video should not be a replacement for medical advice.
Hello! Today we're going to be talking about the ideal positions of neonatal lines and tubes on
x-rays. Stick around to the end because I'll go over some trickier x-rays to test you all
and make sure you've absorbed it all. I'm Dr. Tala and I've been a neonatologist for over 15 years
now and so far it's been standard of care to use x-rays to check for proper line and tube placement.
But we're in an exciting time in medicine and in a few years we'll probably all be using
bedside ultrasounds to check placement of everything. Or even before then maybe artificial
intelligence will help us with some of these x-ray images and for example after one is shot
it will tell us to pull UAC out 1.5 centimeters. That was my robot voice by the way. Or in this
x-ray the robot will tell you that the UVC is too low. But for now this is where most of us are
using x-rays to check position and making our own decisions based on what the x-rays show.
Let's start with the ideal position of endotracheal tubes and ideal location is considered
to be the mid tracheal position. So that's halfway down the trachea between the bottom of the
clavicles and the carina. The carina is where the trachea splits off into two bronchi. In this
figure the letter D represents the mid tracheal position. You can see the carina here and the
undersides of the clavicles here. So D is what you're aiming for. And here is how we look for
the mid tracheal position on an actual x-ray. So look at the base of the clavicles and notice this
is right where the clavicles are closest to the vertebral column. So the lowest portion of the
clavicles. Then you have to figure out where the carina is. Sometimes for example if the baby has
bad RDS this can be pretty easy. Other times it's harder. But here again if you were to intubate
this baby the middle line is where you're aiming for. Exactly midway between the base of the
clavicles and the carina. Interestingly the NRP or the neonatal resuscitation program recommends
that even though we're aiming for the mid tracheal position for ET2 placement we probably should not
be using the clavicles as a landmark because the position of the clavicles really depends on the
position the baby is in and how the x-ray is actually shot. Instead they recommend that the
base of the ET2 should align with T1 or T2 or the first or second thoracic vertebrae. The carina by
the way is usually at around T3 or T4. So obviously the ET2 should be above this. So if we're
intubating a baby how deep should we insert the tube? The equation we're all used to using is
weight in kilos plus six centimeters. So a two kilo baby we would insert two plus six or eight
centimeters from the lip. But as younger babies are being intubated we all figured out that this
is often too deep for the tiny babies. This chart is from the eighth edition of NRP and you can see
that the weight plus six pretty much holds but for the tiny ones the tube is going in less than six
centimeters. But as everyone who's ever taken care of a baby knows sometimes we'll follow the chart
or equation perfectly and when we get the x-ray it's still in a totally wrong position. So we
really should always check placement. So let's look at the position of the ET tube on this chest
x-ray. It's between T1 and T2 so exactly where the black arrow is pointing is where the optimal ET
tube depth is. The tip of the tube like we said is located in the mid trachea adjacent to the first or
second thoracic vertebrae like recommended by the NRP. So note here that the tube if anything
looks like it's kind of at the level of the clavicles. So maybe initially you'd be like
this is too high but more likely the way the x-ray was taken the clavicles are lower than we'd expect.
What about this tube? This was in a paper from Anderson et al. A two month old x30 week infant
presented with listlessness apnea and bradycardia and so was intubated. After intubation they were
able to hear breath sounds bilaterally and the pd cap or the carbon dioxide detector changed
from purple to yellow. But this was the x-ray they got after intubation and here you can see
low lung volumes and the esophagus and the stomach appears full of air despite the fact that there's
also this nasogastric tube in place. Also you can see that the endotracheal tube is right next
to the NG tube. So here what happened was that the ET tube is not in the trachea at all but rather
in the esophagus. So not endotracheal intubation at all but they missed the intubation. As an aside
it's great when groups publish mistakes like this so we can all learn from them. It's very
selfless of them. And here again another x-ray that someone posted for our education. Here you
can see that there is a completely separate air column from where the ET tube is placed and again
the lungs are hazy and collapsed. This all adds up to the fact that the tube is in the esophagus
and not in the trachea. Obviously we're rarely getting these x-rays but this is just a reminder
that sometimes breath sounds and carbon dioxide monitoring will trick you. But what we really
want to see is an improvement in the baby's status whether it's their heart rate or sats.
Now let's at least talk about what happens when the ET tube is in the trachea but not in an ideal
place. In this x-ray we see that the tip of the ET tube is projecting deep within the right mainstem
bronchus. So as an aside if the ET tube goes too deep it is way more likely to go down the right
bronchus because it has a less acute angle than the left bronchus. So the right bronchus will go
kind of off like this whereas the left bronchus is more likely to go off like that.
So here that's exactly what happened and it was a right mainstem intubation. As a result the left
side wasn't getting any pressure and so we ended up with a collapse of the left side of the lung.
There is complete atelactosis of the left lung with actual mediastinal shift to the left.
In the lower x-ray the endotracheal tube had been pulled back to an appropriate position
between the clavicles and the carina, maybe still a little bit low, and with that you can see that
the left lung actually re-expanded again. In this x-ray the opposite thing happened. The ET tube has
been placed down the left main bronchus. Again this happens less frequently because the left
bronchus goes off at a much more acute angle. So often you'd really have to go out of your way to
get the tube there but again as you'd expect you're not getting enough aeration to the right side
and so you do have collapse of this right upper lobe. So if anything it's probably getting minimal
air at all. So here again we need to pull back the ET tube out a little bit. And another x-ray
with the endotracheal tube too deep. So again below the carina. Here again this x-ray shows
the ET tube with its tip projecting deep within the right main stem bronchus and here there is
partial atelactosis of the right upper lobe. So here probably because of the way the ET tube was
pointing and the direction the air was coming out of the tube they were they were getting enough
air to the left lung as well as the right middle and lower lobes but not to the upper lobes. And
by the way often when the tube is too deep we would see a sudden increase of carbon dioxide if
you got a gas. So think about ET tube placement if you ever see that on a gas. A sudden increase in
the CO2. Again here obviously we have to pull the tube back. What do you think about this x-ray?
Here the x-ray looks like the tip of the endotracheal tube is above the thoracic
inlet. So above the clavicles and above T1. Clearly the lungs are getting air in because
even though there are coarse infiltrates bilaterally the lungs if anything are hyper
inflated. But as you all know this baby could have an unplanned extubation and what we used
to call a self-extubation very very easily. And in certain positions the ventilator could be
pushing air down the esophagus into the stomach. We don't want either of these things at all so
this ET tube needs to be pushed in so that it's a little deeper. This is another endotracheal tube
again showing it to be slightly elevated and also just pointing out the calculation that should be
done to figure out how far it needs to be pushed in so that we ends up in the mid-tracheal point.
On most computer programs you can measure out the distance with little arrows and it will tell you
how many centimeters or millimeters or whatever it needs to be pushed in or pulled out. Honestly
sometimes this is still wrong so when you move the tube you should probably be getting another x-ray
to recheck position. Right let's move on to umbilical venous catheters. As you all probably
know the umbilicus venous catheter enters the umbilical vein and the goal is you want it to end
up in the inferior vena cava just outside the border of the heart just outside the right atrium.
So what path does it take? Well it goes up the umbilical vein then through the ductus venosus
which as you all know is like the ductus arteriosus in that it only exists in utero for
blood to take a shortcut and then it ends up in the inferior vena cava. So as you can see from
this picture loads of things can go wrong. The catheter can veer off into the portal veins this
is especially true if the ductus venosus is taking off like a really acute angle or the catheter could
end up in the hepatic veins in the liver or it could randomly go down another vein and end up
in completely the wrong place like this superior mesenteric vein. Ideally we want the catheter to
be on the other side of the liver but just outside the heart. This x-ray is perfect really we want
the catheter to be somewhere around t8 and t9 and again the path of the uvc from the umbilical vein
all the way through the ductus venosus and to the ivc. So again this is just emphasizing all the
different ways that this can go wrong. My friend Dr Reese taught me this mnemonic this is really
for where you want the uvc catheter to end up at t6 or vertebral body thoracic 6 you have to fix it
t7 is heaven t8 is great t9 is fine and t10 do it again. The caveat for this is you still want it
outside the border of the heart and you want it outside the liver. And look at this perfect
position of the uvc and notice the way it kind of makes this bend through the liver that's a
good sign the catheter is passing through the ductus appropriately. So it's on the other side
of the liver but it's still just outside the border of the heart. What about this line placement? Well
if you just count the vertebrae then this looks like the catheter is at t8 or t9 which should be
okay but obviously this catheter is well within the border of the heart and if a catheter is
pushed up against the inside wall of the heart then the fluids or tpn or whatever can seep into
the pericardial space just by osmosis. So it's not like the catheter has to kind of actually poke
through a hole a hole in the wall to cause a life-threatening pericardial effusion and that's
exactly what happened here in this case report. Fluid collected in the space around the heart and
caused heart failure so that needed to be tapped. So take these lines very seriously in their
position very seriously. Another misplaced uvc and this one is pretty impressive. This is not
something that you often see it looks like the catheter has gone up through the right atrium
and come out through the superior vena cava and then carried on going to the confluence
of the jugular and subclavian veins. Obviously way too deep and needs to be pulled back
significantly. Okay and another one where the uvc is too deep and normally if the uvc goes in too
far then usually it travels through the pfo or the patent foramen ovale which as you all know
is the hole between the right and the left atrium and then it ends up in the left atrium. This one
carried on going through the left atrium through the mitral valve and ended up in the left ventricle.
Obviously this needs to be pulled out significantly too and all of these uvcs have ended up in the
liver. If you're still scrubbed in then you can try to make these try to end up in the right place
and you can watch the video we made on uvcs if you want some tricks which sometimes help
but if the line is already in and sutured these need to come out. I'm not sure where these are
whether they're in the portal veins or the hepatic veins but if what we're worried about is if we're
administering fluids and medications into this relatively smaller vein there's a higher chance
of causing a disruption to a vein and then a cyst or abscess in the liver. So if the uvc is in the
then it needs to come out. This uvc did something super weird. It looks like it didn't make it
through the ductus but then instead of turning around and coming outside the same vessel
so kind of coming out the umbilical umbilical vein it turned and entered into another vessel
possibly the mesenteric vein. Again this is in the wrong position and the catheter needs to be
removed. The last thing I want to mention about uvcs is that getting a lateral x-ray
can really help you identify correct placement. The uvc runs superficially and hopefully you'll
see it above the margin of the liver and below the heart. You can see if it takes like a weird
turn there kind of heading backwards maybe even into a spinal vessel or something sometimes.
Check out the uac though which obviously is running in the aorta and this is much more
posteriorly. Many hospitals require lateral x-rays to check placement when lines are placed.
Now let's talk about umbilical arterial catheters. Their path is a little weird. We thread one of the
two umbilical arteries. Remember the umbilicus has two arteries in one vein. I know I've said
it a billion times and then the catheter veers downwards until it joins the internal iliac
artery which then joins the aorta so the catheter then goes back up again. We continue threading
the uac up the aorta until it reaches between t6 to t9. Because the uac has to go down before it
comes up again we generally have to thread the uac in more way more centimeters normally nearly
double the distance of the uvc. This is an aside. At one point when I was in residency we used to do
this. We'd keep uac's in a low position or at l3 to l5. The logic was that if there was a problem
in the line then we'd be more likely to see discoloration of the toes or feet with a lower
line but more data came out that showed that there are fewer complications with higher lines
and so now every institution aims for their uac's to be in a high position or between t6 to t9.
So look at this uac and it looks like it's at a beautiful position at about t8 so 12 11 10 9 8
right there. So this is in a great position and a couple more things I want you to notice. You can
see that the catheter goes down before it comes back up again. You can also see that the uac is
situated to the left side of the uvc and that's always a good way of knowing most of the time
which catheter is which apart from it going down and back up again. This catheter looks like it
correctly went down and then back up again and then seemed to curl around in the aorta.
Obviously this needs to be moved. Often you can pull this out and twist the catheter as you
reinsert it and you may have more luck with a catheter going in. This uac is just too low and
just needs to be pushed in a little further. It looks like here the team thought that this was
the vein that they were catheterizing because this seems to be another uac here but this catheter has
ended up at about l2 so t12 there l1 l2 which is probably the last place you'd want the catheter to
be because the kidney arteries come off from l2. So this would be a really good way to end up with
affecting the blood flow to the kidneys because this is going in the right direction this line
this catheter should be really easy to replace so you can just if you're still scrubbed up then you
can just thread it further up but again you never ever want the catheter to be at the level of l2.
This is one of the most frustrating things that happens when you're threading a uac
and that's when the catheters go down the leg. The catheter instead of going up the aorta the
catheter goes down the gluteal arteries. There isn't really a lot you can do here once the catheter
decides it wants to go down instead of go back up again I really haven't had any luck in changing
its mind. It needs to be pulled out otherwise you may end up with a pretty bad clot and lose the
sacral area or the leg so if it's going down the leg it just needs to come out. And our last x-rays
on uac's you can obviously see that this one has gone way too high. This looks like it's gone all
the way up the aorta but it hasn't threaded into the left ventricle instead it's gone into one of
the great vessels which comes off the aorta. Again this has to come back apart from being in the
wrong position you're more likely to get spasming and a thrombosis but also the catheter is less
likely to draw back blood and less likely to give a good wave reading so that you can monitor the
blood pressure so yes definitely pull this one back. Okay let's go over three test x-rays for
some self-testing make sure you've really absorbed this. So the first x-ray where do we think this
endotracheal tube is? Is it in the right place? Well weirdly it looks like the endotracheal tube
has its tip projecting beneath the carina and not over either of the bronchi so here this looks like
the trachea and then this looks like the carina here because that's one bronchi and that's the
other one and it looks like the stomach is distended. The lateral chest x-ray shows that
there's a column of air probably the trachea which is anterior right in front of the endotracheal
tube so most likely this endotracheal tube is in the esophagus and not in the trachea so another
malpositioned endotracheal tube. All right let's look at this x-ray what do you think happened here?
So let's look at the uvc first and this definitely looks like the uvc because it's to the right of
the vertebral column and it's making that little curve here as it's kind of going through the
ductus spinosus but it doesn't stop it just carries on going and going and going through
the right atrium and apparently up the other side through the superior vena cava and then probably
up one of the jugulars so way way too deep and then what about this uac it looks like it's nowhere
in deep enough so you can see it goes down and then back up again but it's sitting right here
probably t12 l1 l2 l3 so kind of the low-lying uac positions so what may have happened here
is that whoever put these in made one of two mistakes both of which are super easy to make
and we've probably all made at some point maybe the vein and the artery were misidentified so they
thought that they were threading the vein but really they were threading the artery so that
can happen especially if the vessels are really dried up or the calculation was done wrongly so
basically they ended up pushing the uvc much further in than the uac and because we said the uac
normally goes down before it goes up again the uac normally is the one that goes in a much further
distance in this case you're basically going to end up with your lines because they're both really
easy to correct and our last one what's happening here when i first saw this x-ray it looked like
whoever was taking care of this baby was just a little excited with all the instrumentation
and just pushed everything in too far but then i realized this tube is going below the carina
which is right there so it's probably a gavage tube and not an endotracheal tube and probably
a gavage tube it actually looks skinnier and the stomach is not super inflated so no reason to
suspect like all the other x-rays that i showed today that this is actually in the esophagus
wrongly it just looks like it's a gavage tube that hasn't been pushed in further far enough
then it also looks like that both the uac as well as the uvc are in too far again it looks like the
uac has gone all the way up the aorta and into the superior vessels and you can see that uvc
is well inside the cardiac silhouette so both of these need to come out but they're going to be
easy to pull out that's not going to be an issue well that's all we have i hope that you all learned
something today if you did learn something then please like this video and also please comment
and tell us where you're watching from if you're interested in the pdf summary of this video and
really any of the other videos then please subscribe to our neonatal newsletter and you
can see all the details on the home page again thank you so much for being here