Block Control Without Relays Or Detectors? Lionel Style Train Control!

Toy Train Tips And Tricks
93 followers
24 Video Views·Mar 2, 2026
Episode 88: There are dozens of ways to provide non-colliding block control for toy trains automatically: relays, computers, detection circuits, and more. But what if there was a way to do it with just a simple contact, 2 lockons, 2 insulating pins, and some wire?
There is! And Lionel devised this creative solution in the 1950's!
Note: Please excuse the poor camera handling and distorted audio. I had to use my backup system to get this one finished. I should be back to my primary equipment for the next episode.
Thanks for watching!!
AI Generated·May contain errors
["Ramblin' Wreck from Georgia Tech"]
Come all you rounders if you want to hear
A story about a brave engineer
Now Casey Jones bounced around the plain
On a six-speed wheel, a boy, he won his fame
A caller called Casey had a half-assed mole
He kissed his wife at the station door
He mounted to the cabin with his orders in his hand
Took his farewell trip to the promised land
Casey Jones mounted to the cabin
Hello again, this is Mike with Toy Train Tips and Tricks
and today's video was inspired by an old Lionel wiring diagram
that I found in an old Lionel operator's manual
and this diagram showed how you could operate
two trains on a single loop with no collisions
automatic lock control
using no fancy electronics or relays or computers
of course this diagram is from the 50's
before everybody had home computers anyway
but this method uses only a 153C connector
a couple of lock-ons, some wire
and a couple of insulated sections of track
no track modifications are necessary
just insulating the center rail
you can get by without the lock-ons
if you do soldering on your wires
I'm setting this up temporarily
so I was using the lock-ons
and let's see how it works
so at first I looked at the diagram
you see here
and it seems pretty straightforward
that as train A, that's going to be our Rio Grande train up here
our Jeep 7 up here
when it goes over the section
with the 153C connector
here in the dark
it makes a selection
here we can see with the 153C connector
it's an ingenious little device
you have one input and two outputs
and the output is selected
by the position of a contact with a spring
right here
so as the train comes by
and it forces the contact down
it makes contact with this one
and when there's no train
and the spring pushes it up
it makes contact with this one
and you adjust the tension
by adjusting this nut on the spring
now this 153C connector
it came with Lionel's block signals
semaphores, sometimes the crossing gates
and a lot of operators don't use them
for the block signals
for the reason that
in addition to having your on and off
you can also get it into a position
where it makes contact with neither
and in that case
your signal would be blank
neither red nor green
in our case, we're just using it
as a simple on off device
not an either or
so all we have to do is adjust the spring
so that the weight will
discontinue the contact
with our top selection
when there's no train
we have power to the top
when there is a train of any weight at all
it presses down and disconnects
our connection here
which kills the power
to, in this case, this section of track
which we're going to call our stop section
and train B here with our
GM50GP7
when this train leaves
the spring goes back up
restores power to this wire
which comes over here to our lock on
which restores power to the center rail here
and train number 2
goes merrily along
so I hooked it up
the theory is simple
and it failed spectacularly
I had trains colliding everywhere
and I just could not figure out what I was doing wrong
I tried different combinations of locomotives
and trains and I tried
different distances between the contactors
and no matter what I did
one train would always collide with the other
for the reason that
when a train would hit this stop section
once power was restored
this locomotive would have to
overcome the inertia of being stopped
and it takes some time
to build up speed again
to get back to track speed
meanwhile, the other train
is still operating at full speed
closes the gap
and slams into the caboose
so there had to be some way
to overcome the inertia
and finally
after really looking hard
at the Lionel diagram
I found out that the answer was there all along
and that answer was called
a multivolt transformer
nearly every one of
Lionel's post-war transformers
from the lonely 1033
all the way up to the ZW
is some sort of a multivolt transformer
meaning that by attaching
your wires to different posts
you get different voltages
whether fixed or variable
and so you can set up
two different circuits
using the same variable
power to the track
but by having wires
to one set of track
being for example 11 volts maximum
and another set being
16 volts maximum
you can wire it up so that
one section gets
a boost or slows down
relative to the other
train and that's exactly what
we see here in
Lionel's track diagram
so you can either use
a multivolt transformer
with the lower
voltage going to our
control train
the higher voltage going to our
stopped train
or you can use two separate
transformers that are
phased together
by doing this the stopped train
has an extra burst of
power to overcome the inertia
of being stopped
it quickly resumes track speed
and clears the stop block
before the other train
approaches so let's
walk through our wiring
on this track
we have our 153C
contactor
all we have to do with this
is make sure that we pull up some of the
screws and nails so that
the track
well I don't know if you can see that
will be loose enough that as the train
goes by will activate the spring
our input
is our
lower voltage
track voltage or I'm sorry
our higher voltage track voltage
the lower voltage is just
your regular track power that goes to the rest of the layout
this is the higher
voltage that's going to control our stop section
it comes in here
and it
goes out here unless
there is a train
here when there's a train
here it cuts the power
to our stop section
our stop section I'm using
this lock on and here
is that same yellow wire coming from the
153C going to
the center rail we are insulated
here actually here
and here this is my
drawbridge section
so the track is actually
separated there so this
track is our insulated stop
section it's about three
sections long which is about the minimum
you need for this the stop
section needs to be long enough not only to handle
the length of your locomotive but
any momentum
that the locomotive would have
from running through the block
if it's too short
the speed of the locomotive could take it
and connect back to the live track
and run around so you
want it long enough so that you
can stop the train completely
and that's pretty much
all there is to it when train
A is in the
section it turns
off the power to this
train B comes up and stops
until this train clears
the contactor and
power is restored then this one
quickly comes up to speed while the other
one comes around the loop behind
it and so on and
so on a couple
of tips one
make sure both
locomotives have their
E units their reverse units turned
off otherwise when
power is restored you'll go into neutral
the other train will come up and collide
with the rear or in
a two position reverse unit it'll
go into reverse and speed up
the collision process so make sure you're
both locked into your forward position
step two
try to get your locomotives
try to pick two that run pretty
close to the same speed together you'll see
in my video here that the GM50
runs a little bit brighter
than the Rio Grande and tends
to close the gap a little bit
later on I fix that
by adding an extra car
you don't see that in my operating
video but that did help adding
a third car slowed it down
just enough that they run about the same
thirdly make sure
that your trains are not too big for your loop
that there is plenty of running room
from one train to the next
to accommodate
your lack of collisions
and
if you are using the
two transformer method I
find it's best I found
that it's best to use
two older style
transformers rather than
the newer ones 2000
and newer
the newer transformers are a little bit more sensitive
to tracks
to power surges and when
the locomotive comes across and
bridges for just
a brief microsecond
you will have power from
both going into the motor
and that can cause a feedback loop
and kick your circuit breaker
I'm using older
Pullmore motors
and I'm using older style transformers
so yeah there is a short
power spike one I'm using a
TVS diode that will knock
that down a little bit but secondly I'm not
using modern electronics so there's
really not a lot here that I can fry
in the process
I'm just doing this temporarily because I had
to redo the track
work for this interloop anyway
my
secretary of the interior
informs me we need to make some changes to the room
and that is requiring me to change
the track plan a little bit
and since I'm doing that
it's a good opportunity to try some of these
temporary setups
so here we go let's see how it works
in 3, 2, 1
music
alright and as you can see on the track
diagram on the wiring diagram
it's also possible to incorporate this
with a block signal or semaphore
unfortunately none of my block signals are
operating at the moment
but simply
with the 153
if you have the track power to one side
going to the
green and
when the 153C switches
it'll contact
switch to the red for the stop
and back and forth and the wiring diagram
shows you clearly how to do that
and it's
similar to do that also with the semaphore
that's a simple on off
system so
with or without signals that is the
system so until
next time share it, like it, subscribe
tell your friends, tell your neighbors and until then
let's keep the trains running
music