100+ Years Old: How to Clean and Service an Antique Clock

Chrono Chronicles
8 followers
3 Video Views·Feb 25, 2026
I show how I clean and service an antique clock that is over 100+ years old. I am not a professional - I only work on clocks for fun as a hobby, but I try to do things as professionally as I can.
Hey, thanks for stopping by. In this video, I'm going to show how to clean and service
an antique clock. Now, this is a Gilbert mantle clock made in 1885, so it's well over 100 years old.
All right, so let's get into it. First thing I've got to do is get the hands off,
get the dial off, and then I can finally get the movement out, and then the real fun can begin.
Now, I do want to point out that I don't work on these clocks professionally. This is just
something that I do for fun as a hobby, but I do try to do things as professionally as I can.
So, I will be completely disassembling the clock movement, cleaning everything,
cleaning and lubricating the main springs, reassembling everything,
oiling the whole nine yards. So, you'll see how I do all of that in this video.
So, there are four screws that attach the clock movement to the case.
Now, you might notice that these are cross-headed or Phillips screws. So, later in the video,
I will be replacing these with slotted screws to be more consistent with the time period that
this clock was made. All right, so the movement is out, and I'm just going to give it a quick
look over just to see what we're dealing with here, and it does look a little bit dirty.
So, before I start taking the movement apart, it's really important to restrain and let down
the main springs, and what I like to do is use two zip ties per main spring, and each zip tie
has a tensile strength of 60 pounds. Now, there are metal clamps you can buy specifically designed
to restrain main springs, but I've had pretty good luck with the zip ties so far. To unwind
the main spring, I first have to move the click spring out of the way, and then slowly and
carefully unwind the main spring. The first thing I do is actually start to wind the main spring,
which moves the click out of the way, and then I can start to unwind it.
Here, the click did not want to move out of the way, probably because it's a little dirty,
but I gave it a little nudge, and that did the trick. All right, so the main springs are let
down, so now it's safe to completely disassemble the movement. All right, so this movement is held
together with two plates, so I'm going to get these nuts unscrewed, and then lift up the top
plate, which will expose all the wheels or gears and other components of the clock movement. Next,
I'm going to remove the stopworks, and I'll talk a little bit more about these later,
but basically what they're designed to do is limit how much a spring can be wound or unwound
by kind of jamming or locking up, and both of these are currently in that locked up state,
meaning I couldn't unwind these springs any farther. So if you're new to working on clocks,
this is where things can get pretty overwhelming, because once you take that top plate off,
you're just left with a pile of gears and various components and things like that. So this is where
you want to take any pictures or reference video, so you can use that later on to reassemble
everything. So you might be wondering why you can't just take the entire assembled movement,
dunk it into some solution, swish it around a little bit, and dry it off, and the answer is
you could do that, and there are people that just do the dunk and swish method, but it doesn't
really get everything clean, especially the important areas like the pivot holes.
The cleaning solution can also get trapped in certain areas and not dry fast enough,
so rust can quickly form on steel parts. Also, if the mainsprings are in barrels,
then I'm sure moisture would certainly get trapped, and you also can't properly clean and
lubricate the mainsprings without taking them out of the movement. Also, you can't properly clean
and inspect the pivot holes and inspect all the parts without fully disassembling the movement.
So it's not just about cleaning, it's also about finding where the problems are.
So just dunking the assembled movement, trying to dry it off, and calling it clean
might work in the short term, but any remaining dirt will act as an abrasive and shorten the life
of the movement. So cleaning without disassembling the movement is like taking a shower with your
clothes on. You might look clean, but I bet you missed some important areas. Next, I'm going to
move the count wheel clip and the count wheel. And the mainspring that you see here drives the
striking side of the clock, and the count wheel actually determines how many times the clock's
going to chime. So it'll chime once on the 30 minute mark, and it'll chime the number of times
for whatever hour that it lands on. So if it's five o'clock, it'll chime five times. All right,
so this is what a completely disassembled Gilbert clock looks like, at least for this model. Now it's
time to remove the mainsprings from the great wheels. So this is a mainspring winder that I
designed and built myself, and I've been using it the last couple years with pretty good success.
Now you can go out and buy a mainspring winder, but it'll cost you a few hundred dollars or more.
And this one cost me a little under $80 to make. So it's really important that you wear a face
shield and leather gloves when you're dealing with these mainsprings, because if they get away from
you, you could really get yourself hurt. And later on in the video, when I go to wind up one of these
mainsprings, some things went down, and a mainspring got away from me. Not once, not twice, but multiple
times. And I'm really glad I was wearing a leather glove, because had I not, well, I think things
would have gotten pretty bloody for me. So stick around and you'll see what happened. All right,
so now it's time to remove the mainspring from the great wheel. And this can sometimes be pretty
tricky, because there is a pin on the side of the arbor that is inserted into a hole in the
innermost coil of the mainspring, and you can kind of see it there. Best case scenario, all you would
need to do is rotate the arbor like you're unwinding the mainspring, and the pin should just pop out of
that hole. But this mainspring is pretty old, and those innermost coils are really tight, and it
doesn't leave enough room for that pin to move out of that hole. So what I'm trying to do here is use
a flathead screwdriver just to widen that hole just a little bit, so I can wiggle that pin free.
And I ended up fiddling with this for quite a while, but eventually I was able to get the pin
popped out of that hole. So if you look right there, you can see the pin, and it's no longer
in the hole in the spring. So I should just be able to pull the great wheel off of the spring now.
And there we go. One thing I noticed about this mainspring, other than it being really dirty, is
that it's completely dry. There's no oil or lubrication at all on this mainspring. To clean
the mainspring, I'm going to use WD-40 and some steel wool, and typically it's best practice not
to get WD-40 anywhere near your clock. But in this case, I'm going to use it as a cleaning agent, and
then I'm going to use mineral spirits to remove any leftover residue that the WD-40 might leave
behind. And that's just to clean the mainspring. After it's clean, I'm going to use some mainspring
lubricant to finish it off. Alright, so this mainspring is cleaned and lubricated, and it's got
a nice shine to it now. Alright, so now it's time to deal with the mainspring that drives the time
side of the clock. And I'm going to follow the same procedure that I did on the other mainspring.
So one thing I noticed right away on this mainspring is that the innermost coils are
really tightly wound, and I fear that I'm going to have a really tough time getting that pin out of
that hole. Yeah, that pin is even beginning to budge, so now I'm going to have to try to widen
that innermost coil a little bit. I ended up fiddling with this for quite a while, and I didn't
show it all here in the video just to save you from some of the pain that I had to go through,
but I eventually got the pin out of the hole, and I could remove the great wheel from the
mainspring. One thing that I noticed, other than my fingers are now really dirty, is that there
seems to be some sort of defect in the metal there, and I'm not quite sure what would have caused that.
Now that the mainsprings are cleaned and lubricated, it's time to clean all the other
parts of the movement. So I finally decided to buy a bigger 6 liter ultrasonic cleaner, which is
a huge step up from my little dinky ultrasonic cleaner that's really meant for small pieces of
jewelry or things like that. So what I decided to use was Crystal Simple Green and some distilled
water, and I wasn't quite sure of the exact ratio to use, so I just did a little bit of the Crystal
Simple Green. So I did a lot of research online to try to find out what was the best solution to
use, and it seems like everyone and their dog has their own concoction that they mix up, but I didn't
know which direction to go, so that's why I decided to go with the Crystal Simple Green, because it
seemed like a pretty safe solution to use. So I set this up to run at 40 degrees Celsius, which is 104
degrees Fahrenheit, and to run for 20 minutes. So let me know what you guys think on those settings.
Is that too hot? Not hot enough? Is that too long or not long enough? I decided to add a mesh screen to
the bottom of this basket, because I didn't want anything sticking through and making contact with
the bottom of the ultrasonic cleaner. I would imagine that would wreak havoc on any of the
pivots. So I bought this pack of mesh screen, which is the same type of stainless steel the basket and
the ultrasonic cleaner is made out of, and cut it to size and stuck it down there in the bottom.
This is the first time using this ultrasonic cleaner and the solution, so I'm a little nervous
and excited to see how things turn out. Wow, look at that. I think it did a pretty good job.
Now I'm going to clean everything with mineral spirits, just to make sure there's no leftover
solution residue, and then I'll dry everything with a heat gun. So it looks like the ultrasonic
cleaner didn't get everything off, and I don't know if that's because I used the wrong temperature
or the wrong time. So if you have any thoughts on that, just let me know.
I'm really quite impressed how clean these parts came out of the ultrasonic cleaner.
There was just no way I could get things this clean by hand.
So just to show a quick comparison, the great wheel on the right has been through the ultrasonic
cleaner and the one on the left has not, and you can really tell the difference there.
So one thing I was wondering about as I was going through this process was if I was utilizing the
space in the basket correctly, because one thing I was nervous about was packing the basket too full
or the parts would rub against each other and actually cause some sort of damage.
So I decided to do things in smaller batches just to be on the safe side.
Now I did check over both plates to look for any worn pivot holes, and I didn't see any. They all
looked pretty good to me, but what a worn pivot hole could look like is more oval or egg-shaped
instead of perfectly round. So if you're having a problem with your clock running or it won't stay
running, it might be because you have a worn pivot hole. And what tends to happen over time
is that dirt accumulates within the pivot holes combining with the oil and makes kind of like an
abrasive slurry. And as the wheels turn and those pivots turn within those holes, it slowly grinds
and sands away the pivot hole and makes it an oblong shape. And that'll bind up the wheel from
turning at all, or it might misalign everything and that'll completely stop your clock. So I
decided to prop the hammer up like that because there's a leather tip on the end, and I didn't
know how that would react to the solution. So I just try to keep it out of there.
All right, so now it's time to put everything back together. And I'm going to start with
the mainsprings, and then I'll move on to assembling the movement. Now I'm going to try
to attach the mainspring back to the arbor on this great wheel. And as you can see, this is for the
striking side of the movement because it has the count wheel on it. And so the trick is to get that
pin to insert just right so it goes into the hole in the inner coil, and then it should just pop
right in. And there we go. So now I'm going to give it a few turns just to make sure that the
pin really is in that hole. And you can see that the spring is rotating when I turn it. Now I was
really concerned about this mainspring because that inner coil is so tight that I was nervous
that I wouldn't even be able to get that arbor to fit in there. It goes in, but there's not enough
room for that pin to go in. It's stuck on the outside as you can see there. So now I have to
figure out a way to get that hole to widen up a little bit. So it looks like it snapped in right
there, but as I was turning it and looking in the inner coil, I could tell that the pin wasn't
actually in the hole. It was stuck on the side of the inner coil. So now I've got to try to pop the
spring off and try again. So I wasn't quite sure what tool to use to widen that hole a little bit,
so I decided to use these, which might have been a bad idea. I think I ended up bending the tool
more than the inner coil, but I think it did the trick.
All right, it looks like I got it. It might be hard to see here, but the pin is in the hole
and the spring is turning when I spin the arbor. All right, so now it's time to wind up the
mainsprings and everything went as planned on this one. The next spring, however, not so good.
After watching this back, I can see what I did wrong on this one. I slowed down winding it up
and then I accidentally started winding it the wrong way and it popped off, but my problems did
not end there. And the other problem I was having is I can't feel what my fingers are touching
through the leather glove and I kept knocking the hook out of the loop on the mainspring. I also
think I wasn't winding the spring up enough and it kept wanting to cone out to the side, which was
also causing me some problems. Now this one was the scariest of them all. I thought I really
screwed up the mainspring on this one. It was all tangled up in itself. All right, so I finally got
it. So now I'm going to quickly get this thing zip tied so I don't have any more surprises.
So one of the limitations of this mainspring winder is I need to have a free hand to set
the lock on the crank. And when I'm having problems like I just had, it makes it extremely
difficult to do that. So at some point in the future, I might make a modification to this winder
to solve that problem. Now it's time to reassemble the movement and this is where any reference
pictures or videos really come in handy if you forget where something goes. Here I'm showing
how I calculate the beats per minute, or BPM, that the clock should run at. And I do this by
counting the teeth in the pinions from the escape wheel to the center wheel. So before I reassembled
everything, I took those wheels aside and counted everything and wrote those numbers down, did this
simple calculation, and I came up with a number of 148.57. So later on in the video, I show how I set
the clock to pretty much run at that rate. Alright, so this is where things can get very, very time
consuming. At least it does for me. And that's because you have to get all of the pivots back
into their pivot holes. And so what I like to do is I'll start in a particular corner and screw down
that nut so the plate stays in place. And then I slowly go to each pivot and try to get them to go
back into their pivot hole. And this is what it looks like between the plates. It's just a mess in
there. So you really got to have some patience and try not to force anything. If something isn't
going where you want it to go, try not to force it too much. Take a step back and look at what's going
wrong. And then go from there.
Here I'm taking the spring wire for the count lever and trying to wrap it back around that post. And
that didn't work. So I'm going to try to put a little bit more of a bend in that so it wraps around that
post a little bit better. And there we go. Now the count lever should be a little springy.
Okay, so now I'm going to do a quick test of the striking side of the movement just to make sure I
set up everything correctly. The count lever should stop on each of those deep notches on the count
wheel. So there is a warning pin on the warning wheel, the one that I'm turning right there, that
should fall in the path of the locking lever at the appropriate time to stop the count lever from
raising back up again. And it looks like everything is working the way it should. All right, so a
little bit more about the stop works. So this star wheel has one extra long tooth with a total of
eight teeth and it belongs with the winding arbor. The other star wheel has a total of nine teeth with
one shallow valley. So as the mainspring unwinds, since they have a different number of teeth, a
given tooth on the drive star wheel will mesh with a different valley on the other star wheel. So when
the long tooth lands in the shallow valley, the mainspring stops unwinding because the stop work
gears are effectively jammed. And the same is true for winding. So here I've configured the stop works
to not allow the mainsprings to unwind beyond where they are right now. So the purpose of the
stop works is to restrict the winding and unwinding of the mainspring to the central flat part of the
release curve and avoid the extreme ends of that release curve. All right, now that the movement
is cleaned and reassembled, it's time to oil all the pivots. And if you're using the correct type
of clock oil, what should happen is the oil should pretty much suck into the pivot hole
via capillary action and just kind of stay there, which allows the pivot to kind of float and freely
move within it. And like I mentioned earlier, this is where dirt will get trapped over time
and combine with the oil to make kind of like an abrasive slurry and sand those pivot holes away.
Okay, so we don't need these zip ties around the mainsprings anymore. So what I'm going to do is
start with the striking side of the movement and get that wound up a little bit and cut off the
zip ties. And then I'll test the striking mechanism just to make sure everything is still working
correctly. So if everything is working correctly, the warning pin should engage with the locking
lever and stop the count lever. And it looks like it's working. Now it's time to start winding the
time side of the movement. If everything is working correctly, you should start seeing the clock tick
and come to life, which is pretty exciting. So I bought a box of these slotted screws,
so we won't be needing those other screws anymore. I'm going to take out four of those
and get the movement back into the case. A little bit ago, I looked at where the count
lever was on the count wheel to try to figure out where to put the hands back.
And here in a little bit, I'll give it a small test just to see if I put those in the right spot.
So if I put the hands back in the right spot, it should chime eight times. Okay, so that was nine
times. So this is how you fix it. Pretty simple. Now it's time to attach the pendulum and get the
beat rate set correctly. So I use this app, and there's a link in the description for it, that
listens to the ticks and tocks of the clock and calculates the actual beats per minute,
which is in the lower left-hand corner. It also looks at the consistency of the beat
and whether the clock's leveled or not. So it's packed with a lot of helpful information.
Right now it's saying I need to raise the bob on the pendulum. So now it's saying that the
beats per minute is around 148.3.4, which is still lower than the calculated beats per minute that I
calculated, which is 148.57. So I got to raise it up again. All right, so now it's saying around
150 beats per minute. Somehow I raised it up too high. So I got to lower the bob now. Now it's
saying around 148.43, which is pretty close. I think it's close enough. Well, thanks for taking
some time to watch this video. Please feel free to like and subscribe, because that really helps
support the channel. Thanks, and take care.
