Histology Techniques and Equipment

Biologists and Doctors
10 followers
1 Video View·Jun 3, 2025
Have you ever wondered how we get a piece of tissue onto a glass slide so that we can
view it down the microscope?
Well I'm going to take you through the processing technique and the equipment that's used in
the pathology laboratory that actually makes these glass slides so that we take a big piece
of an organ and we make it as thin as a piece of paper so that we can view it under the
light microscope.
Once the tissues have been taken from the body, for example a suspicious mole, a ruptured
appendix or even a cancer, the tissue needs to be prepared and processed so it can be
viewed by the light microscope on a glass slide.
The first step in tissue processing is specimen accessioning.
This is part of what is called the pre-analytical procedure.
Tissue specimens are received in the diagnostic pathology laboratory and they come with a
request form that lists the patient information and the history about the patient along with
a description of the tissue that came from the patient's body.
After the patient details have been identified with their name, date of birth and identification
number, the specimens are accessioned by giving them a lab number that is unique for each
patient and will identify each specimen for the patient in the histology laboratory.
After the specimen has been accessioned, the pathologist or the scientist conducts a gross
examination whereby the tissue is described and measured and all or some of the tissue
is prepared for tissue processing.
Some of the tissue is removed from the organ and it is placed into a cassette.
The cassette is able to hold the tissue in place while tissue processing occurs.
The cassette is also used in the embedding process which we will look at later on.
The purpose of fixation is to preserve the tissues permanently in a lifelike state as
possible.
Fixation should occur as soon as possible after the tissue has been removed from the
body and this usually occurs in the operating theatre but sometimes occurs in the lab.
Fixation reduces autolysis, otherwise known as tissue degradation.
There are a variety of fixatives that can be used depending on the type of tissue present
and the features to be demonstrated.
The routinely used fixative is an aldehyde called formalin, otherwise called formaldehyde.
Once fixation has occurred, the samples are placed into a tissue processor which is an
automated machine that pumps the chemicals in and out of the tissue specimens.
This is necessary to remove the water from the tissue and replace it with the molten
paraffin wax.
The molten paraffin wax will eventually set hard so that a microscopic section can be
prepared.
The embedding centre consists of a hot and cold surface.
The high temperature keeps the paraffin wax as a liquid so that it is easier to manipulate
the tissue sample from the cassette to the mould.
At the embedding centre, the tissue sample is removed from the cassette and is placed
into a mould.
The embedding centre consists of a hot and cold surface.
The high temperature keeps the paraffin wax as a liquid so that it is easier to manipulate
the tissue sample from the cassette to the mould.
At the embedding centre, the tissue sample is removed from the cassette and is placed
into a mould.
The mould is filled with liquid paraffin wax.
The microtome is a bit like the deli slicer at the grocer's.
This instrument has a very sharp knife that enables a very thin section of the tissue
sample to be cut as thin as a piece of paper.
It is very important to follow the safety guidelines and know how to use the roll bar
and the safety lock on the microtome.
The very thin sections that are cut form a ribbon of approximately four to five sections
of tissue.
These sections can be floated out onto the water bath.
The warm water in the water bath allows any wrinkles or creases in the tissue section
to be smoothed out so the section is nice and flat.
The section can then be picked up from the water bath and placed onto a glass slide.
Once the section is on the slide, the wax supporting the tissue can be removed and the
tissue can be stained using dyes so that we can visualise the tissue structures from our
section under the light microscope.
So now you know what happens to a tissue sample taken from the body and how we can visualise
it on the microscope to see the structures of the tissue.
Cut!
Okay, so that's done, that's done.
Can we get something back?
Yes.