Lecture 59 : Cell Based Biosensors - Part 4

IIT Kanpur July 201
20 followers
2 Video Views·Oct 4, 2024
So, welcome back. So, I told you when I close the last class, I told you that just translate
this whole thing. So, here you have a electrode which could stimulate these muscle which is
sitting on top and because of a motion, it will generate a vibration on this micro cantilever.
Because of that vibration, there will be a motion something like this and there will
be change in this angle of reflection and here is the laser. It is a low intensity laser.
So, you do not. So, what you are doing is that you are shining the laser. If this is
your cantilever, this is how the cantilever is sitting and let us assume this is the muscle
on top of this blue color pen. Here you have a laser beam shining this black pen underneath
the cantilever and here is the reflected light which is coming and here is some sensor somewhere
out here. So, this is the instant light and this is the reflected light and because of
this movement, there is a change in the reflection and this angle of change, you are measuring
it as theta. Now, I told you that you can back calculate
the force. I would request you guys to go and look for a equation which was published
in 1909 by Stoney's called Stoney's equation. If you read through Stoney's equation, this
is not part of this course. This is just for your own interest sake. You will realize that
if we consider this as this muscle as a monolayer on top of this cantilever, this angle theta
which is being generated here. If we plug this with some modification or some assumption,
you can back calculate the force. So, this is a technology where, so this is exactly
is the same thing where laser beam, you can make this laser beam move from one cantilever
to the next one, third one to the fourth to the fifth to the sixth to the seventh. Likewise,
of course, with a delay, it will be moving through and it will give you the different
theta angles. Now, this is a technology which is called as the micro cantilever array for
monitoring activity of muscle. Now, in this situation, you can think of many options.
Say for example, you introduce in this milieu a toxin. How this toxin is going to influence
the muscular activity or you add some say sports medicine or drug or performance enhancement
drugs which are used by lot of athletes. How it influences the muscular contraction? So,
without harming animals, you can really do a lot of micro fabrication work which falls
under the broader domain of MEMS, micro electro mechanical assistance for system.
In other word, if you look at your own body itself, your muscle is nothing but a cellular
micro electro mechanical system and you are integrating it on a synthetic micro electro
mechanical system which is a cantilever and you are doing this kind of measurements. So,
this is another technology where you can marry micro electrode array with micro cantilever
array. Now, this particular technology is revolutionizing most of the toxins which are
being tried out on neuromuscular junctions because in a way, now you have could visually
see the effect of these kind of technologies. Now, from here, I translate it to the next
level. So, we talk about two organs. Now, the next technology which is coming, I was
telling about human on a chip or lab on a chip technology. What people are trying to
do? They are creating these kind of structures where you have neuronal chamber, you have
muscle chamber, you have liver, you have cardiac muscle. So, these are brain neurons, you have
skeletal muscle, you have pancreas and they are connecting them using different micro
fluidic channels and using micro valves. They are creating a multi organ system, a functional
multi organ system which mimics the human body and most of these cells, they derive
from the stem cells, different source of stem cells which are being used.
So, in a way, it is far more easier now to and you will be surprised to know United States
FDA has approved. This happened this very year 20, 23, 24 where every FDA has approved
any drug has been tried on these kind of systems. They can bypass all the animal trials and
directly go to the human trials. So, this is a major development which is happened exclusively
for the drug discovery industry, but this exactly holds a promise for screening of wide
array of bio defense molecules and toxins warfare agent where animal screening is not
only painful, dangerous as well as inhuman. Ethically, it is extremely challenging.
So, now when we talk about these kind of things, so we talk about arranging the brain in terms
of the circuit, arranging the skeletal muscle on say micro cantilever array, arranging the
circuits of on a micro electrode array. On the liver, you can really create pattern substrate
almost mimicking the liver. Similarly, the cardiac could be put on again on MES. Pancreas
could be patterned and these are all the micro fluidic channels which in a way are mimicking
blood vessels. This is the most advanced technology currently being used or at the
very niche stage of development. Those of you who are interested, they may visit this website
or see this company HESPEROS, H E S P E R O S, HESPEROS I N C. It is a US based company
based from Orlando. You may visit their website. It is pretty interesting. You will see because
they are the first company in the world which develop multi organ human on a chip system
and they are the front runner in the world. In US, they are the leaders. It is a small
company, but it will tell you many things. If you look at it very carefully, you will
realize that there are several things to ponder upon, look upon. What I am telling you is
much of their studies which has happened there for last 24 years and prior to that even like
they have been working in this area since 1985. It is almost now 35 to 40 years they
have been working in this area and today they are one of the top most companies in the world.
Similarly, you can integrate other things like you can integrate kidney. So, sky is
the limit. The only thing is and by the way whenever we are doing these kind of things,
so there are other techniques what you have already learnt about you can pull the fluid
out from there and you can give them to H P L C column and see how what kind of metabolites
are being originated, how the toxin is affecting. Say for the toxin is affecting liver and liver
secretes certain metabolites which influences the skeletal muscle or the neurons. It is
extremely challenging to understand these kind of interaction what is happening, but
in a system like this you can study them or say for example, if the liver gives out some
metabolites which is detrimental to the cardiac system. How do you come to know, but what
you observe is a cardiac arrest, a certain cardiac arrest or the metabolites influences
the pancreatic islets of Langerhans cells. How you figure or it puts a indirect effect
on the kidney in the purification process. There are so many possibilities this technology
is opening up, but this technology demands very clear understanding of some of the techniques
what I highlighted you previously is here. You have to understand basic photolithography
tools, you have to understand have a better knowledge about electrochemistry. That means
you have to understand how to handle electrode, how to implant electrode, how to ensure the
recordings you are taking. Then you should have a very good system for
micro system fabrication, you should be able to fabricate things at the micro dimension
and with very high precision, because the resolution is not very high it is in the micro
meter resolution, but it has to be very thorough. Then you have these channels, connectors channels
then comes the electronic interface. So, you have to for these kind of systems you have
to have your own set of softwares, you have your own set of hardwares to work along with
this. Then the integration part where you are going to integrate the cells, you have
to have a complete understanding of the cell culture technologies which are involved. So,
how either from primary cells or from cell lines or from stem cells, what will be your
source of cells, how you are going to handle the cells, how you want to grow the cells.
When we are talking about cell culture, you have to have a thorough understanding about
the extracellular matrix, because you are integrating a biological system on to a synthetic
interface. So, unless you have a very clear understanding about how you are going to interface
these cells with the extracellular matrix and extracellular matrix on top of a synthetic
substrate. So, this whole interfacing is of immense importance when we are talking about
the integration of the cell. Then comes the device, how the device have to be developed,
how you are going to do a packaging that is after all these things you have to pack it,
because you will be doing a real time monitoring. So, when we are talking about the chips like
this, something like a chip like this, it should be packed thoroughly and then you have
to ensure a septic practices. So, that you are handling biological cells, there is every
chance of contamination, microbial contamination handling clean rooms. So, realize that the
sensor technology is now going more on cell based sensors, this is where the future lies.
The whole biosensor, biodefense mechanism is all about cell based sensor systems. When
we talk about the cell based sensor systems, we are talking about as I was mentioning you
have to have a full legit idea about how you are going to play with the different kind
of electrodes, what all information you want to gather from the electrodes, what will be
the electrode material, how you will have these materials which are economical, which
are easily available, how you can get these materials, how we can do these kind of things.
So, unless you have a thorough idea about all these technologies, you will have a lot
of challenges. So, that brings us a lot of opportunity that when I mentioned in the beginning
that the field of biosensor is extremely challenging, because it demands expertise from multiple
areas. Having said this, I will tell you a very interesting part of a challenge. So,
when we are talking about as I mentioned, so you have a electrode, on electrode you
have a excitable cell, where this is your electrode and this is your excitable cell.
As I mentioned that whenever there are influx, you see a change. If you remember that graph
I showed you that is something like this, that means there is an electrical activity
happening, where the x axis is giving you the time and y axis is the voltage. In all
these situations, what we are talking about is the cell is in direct contact with the
electrode, just like all other biosensors, where the molecule is in direct contact with
the electrode. Now, the challenges here in the next class, we will talk about what are
the challenges and how we can graduate to the next generation technologies. This will
be the topic of our next class. So, thank you and in the next class, we will talk about
the challenges and the next generation technologies.