POMPE DI CALORE: BOLLITORE, PUFFER, INERZIALE

TecS
22 iscritti
2 Visualizzazioni video·7 dic 2023
https://www.youtube.com/watch?v=-yPjZDmBr5Q
In questo video cercheremo di capire la differenza tra questi componenti dell'impianto termico, spesso confusi.
Naturalmente come al solito resto a disposizione per qualsiasi chiarimento alla mail [email protected]
Possiamo fare due chiacchere sul gruppo Facebook https://www.facebook.com/groups/31813...
Hello everyone, today we will talk about some components of the thermal system related to heat pumps, but also heaters, on which an idea is perhaps not always clear, sometimes there is a bit of confusion
so we will try to understand the function of the hot air blowers and thermal or inertial flywheels
the first of these categories, then hot air blowers, what are they, what are they for?
why do we say that the hot air blowers are part of the same family?
because basically in both cases we are talking about containers full of water, of liquid in general, in which one or more exchangers are immersed
in order to make a kind of thermal collector
we are talking about puffers, when the water in which our boiler is full, our container, goes to give heat to the exchanger
while we talk about boilers when the same water container is heated, therefore absorbs heat from my exchanger
so basically we have a puffer when, for example, we have an accumulation of hot water in which there are several coils that receive heat from this hot water
as for example it can be a puffer that produces hot water, or a puffer where there is hot water heated by several coils in which hot water is poured for various sources
we are talking about boilers when, in the classic situation in which you have sanitary water inside this container, and one or more coils go to heat it, thus heating the entire mass of water and producing hot water for the various sources
for example a pit, the so-called pit, like the one we find on the Daikin Altherma 3 Compact, that is basically a puffer, a technical water that heats my sanitary water and therefore a semi-instant production is made
What is the difference with thermal or inertial boiling? Thermal or inertial boiling is a whole other thing, in the sense that it is basically an empty container, often as a vent, a container in which there is a content of technical water
This container has basically two functions, the first function is to go and do it from the flywheel, then from the hot water accumulator, so I go to store my heat in these containers of hot water, which I can then use at a later time
So for a while I was able to take advantage of the amount of free heat that the sun gave me during the day, so this could be a function to have a heat reserve
A second function that the thermal flywheel has, inertial, is to compensate for a small amount of water inside my heating circuit, so systems that are low-inertia, such as an aluminum correlator system or a fan system
Where, for example, I could have little hot water in the circuit and consequently not be able to manage the power supply of my heating pump in a homogeneous way
Because a heat pump of 12-16 kilowatts needs a certain amount of water to prevent it from continuing on-off
Consider, for example, that on today's heat pump, 5 liters per kilowatt are generally considered, that is, a heat pump of 12 kilowatts with a good modulation needs at least 60-70 liters of water
And this also makes us understand the technological level that a heat pump system can have compared to a wood or pellet system
So, when I have an interface on a system, I must first know the exchange rate and also the volume of water that I have in the system
It is a system that will have at least 100-120 liters, because steel radiators, big ones, in tubular, have a nice literage
So there is the category of those that the heat pump never puts, and the category that would always put it
They put it but it's wrong because in some cases you need it, they always put it but it's wrong because it's true that in practice it doesn't hurt that much, but it's a volume of water that we have to heat and that maybe we don't need to heat
And so, however, it costs me a little bit, it costs me both in terms of electrical energy of the pump, but above all it costs me from the thermal point of view of the electrical absorption of my heat pump
So when you need to mount a monothermic, as we said before, systems with aluminum radiators, therefore with a low amount of water, systems in fan coil, then also in this case low amount of water and high inertia
But, as I say, it is not mandatory to mount a thermal flywheel, it is not that the standard systems have the thermal flywheel and the non-standard systems do not have it, you have to evaluate case by case
For example, for the radiator, the thermal flywheel is useless because I have a lot of water and a lot of inertia, so I don't need an inertial if I have a lot of water and a lot of inertia
but to balance the supply of the heat pump by giving the system the right amount of water
I close the speech by saying that a perfect system is a system that basically does not need a thermal flywheel
I will make a separate video where I will show you how wrong I saw and found thermal flywheels and puffers in some systems, sometimes to make you understand in a real way what mistakes are sometimes made when using this type of instrument
We live in a free and democratic world and if you have something to say, say it without any problem, so a dear greeting and a big hug from Antonello and see you in the next video!