전력용 변압기 시험

OMICRONenergy
9 followers
Oct 19, 2023
변압기는 손실을 최소화하기 위해 송전 시 단계적으로 승압하거나, 배전 시 강압하여 전압 레벨을 변환합니다. 정상 가동 중이고 특히, 전기 고장이 발생한 상태에서 변압기는 전기, 기계, 열 및 환경적인 영향에 놓이게 됩니다. 따라서 공공기관 및 서비스업체에서 변압기의 상태를 판정하고, 유지 보수 작업 일정을 잡고, 교체 계획을 수립하기 위해 전력 변압기를 시험합니다.
웹 사이트를 방문하십시오: https://www.omicronenergy.com/ko/
In order to minimize the loss of the transformer, the transformer is step-by-step upgraded when it is soldered or reinforced when it is soldered to change the voltage level.
The transformer is one of the most important assets of the public power industry.
If a new transformer is manufactured and transported to the site, a considerable cost is incurred.
However, the cost of the damage caused by the malfunction of the transformer and the loss of production may be much greater.
Therefore, organizations try to keep the transformer running for as long as possible.
When the transformer is in normal operation and, in particular, when there is an electrical failure, it is affected by electrical, mechanical, heat, and environmental factors.
The transformer is exposed to mechanical stress when it is transported from the factory to the site, when it is placed between power stations, when an earthquake occurs, or when an external failure occurs.
The transformer must be able to withstand the stress of motion transfer, as well as the pulse transfer, such as pulse wave or switching pulse.
Most of the internal losses caused by sub-currents must be eliminated.
High temperatures worsen the condition of the transformer components.
Due to the stress of the transformer, explosions and fires can occur.
Not only does it take a long time for a new transformer to be replaced, but also long charging periods for repair at the factory can cause economic damage.
Therefore, public institutions and service companies determine the condition of the transformer, set a maintenance work schedule, and test the power transformer to establish a replacement plan.
The most common measurement methods include the test of the resistance of the power line, the test of the transformer, the conversion ratio, the female current measurement, the charging capacity, and the genetic measurement.
The test of the resistance of the power line and the test of the factory can be used to determine the power line loss or the power line damage that can occur, such as the power line lead line or the power line failure of the transformer.
The measurement of the conversion ratio and the female current can identify the failure between the power line turns.
In order to evaluate the failure of the transformer, the charging capacity, the genetic measurement, and the reverse rate measurement are carried out.
After an electrical failure occurs, a high-quality diagnosis measurement can be used to check the structure and the state of the power line.
For example, it can be used to measure the failure impedance, the reactance of the current, the frequency response of the power line, the reverse rate or the genetic measurement that deviates from the frequency range.
Through regular diagnosis measurements and maintenance work, the demand for power supply that public institutions and service companies can always trust can be satisfied.