KTU BIOMEDICAL ENGINEERING || EC365 || MODULE 2 || LECT 10
This video lecture contains
1.ECG BLOCK DIAGRAM
2.BLOOD PRESSURE
3.BLOOD PRESSURE MEASUREMENT-AUSCULTATORY METHOD
For the full video of this course : https://www.youtube.com/playlist?list=PL2UV2EJdMQmh3GlNha5gwN8IsIyjOKcGh
#ktubiomedical #biomedicalengineering #ktu
Hi all,
There are two things that we have included in this lecture.
In the last class, we discussed about ECG.
Now, we are going to study about the block diagram of an ECG device.
Also, we are going to discuss about how to find the blood pressure.
So, what we see in this figure is the block diagram of an ECG device.
This is the block diagram of an ECG device.
Let's have a look at this diagram.
You can see ECG electrodes.
So, what is the function of ECG electrodes?
Why we are using ECG electrodes?
We have studied about the potentials in a patient's body.
Electrodes pick up the potentials in a patient's body.
Then, a lead selector is switched on.
The function of the lead selector is to select the electrodes based on the lead program 2x2.
Then, a pre-amplifier is switched on.
Pre-amplifier is also known as control amplifier.
Pre-amplifier is used to prepare the electronic signal for further amplification and processing.
A differential amplifier is used as a pre-amplifier.
A 3 or 4 stage differential amplifier is used as a pre-amplifier.
So, what is a differential amplifier?
We have studied about differential amplifiers in electronic circuits and operational amplifiers.
We have discussed about instrumentation amplifiers in the previous session.
The purpose of instrumentation amplifiers is to amplify weak signals.
A pre-amplifier is used as a 3 or 4 stage differential amplifier.
The output of the pre-amplifier is fed to a power amplifier.
The function of a power amplifier is to drive the output device.
The output of the power amplifier is fed to the pen motor which deflects the writing arm of the paper.
The output of the power amplifier is fed to the pen motor.
The output of a power amplifier is to drive the output device.
The output of a power amplifier is fed to the pen motor which deflects the writing arm of the paper.
A frequency selective RC network is used to provide damping to the pen motor.
An auxiliary circuit is used to provide a 1 mV calibration signal.
This is the basic working of an ECG device block diagram.
The potentials picked by the patient electrodes are taken to the lead selector switch.
Here, the electrodes are selected 2 by 2 according to the lead program.
The signal is then given to the pre-amplifier.
A pre-amplifier or control amplifier is an electronic amplifier which prepares an electronic signal for further amplification or processing.
It is usually a 3 or 4 stage differential amplifier.
The amplified output is then given to the power amplifier.
The output of a power amplifier is fed to the pen motor which deflects the writing arm of the paper.
A frequency selective RC network is used to provide damping to the pen motor.
The auxiliary circuit provides a 1 mV calibration signal and automatic blocking of the amplifier during the change in the position of the lead switch.
It also includes a speed control circuit for the charge driver motor.
So, that's all about the working of that block diagram.
This is the diagram of the lead selector, pre-amplifier, power amplifier, auxiliary circuit, pen motor and chart paper.
This is a more advanced diagram of ECG.
You can refer to the other block diagram.
So, that's all about ECG.
Next, we will discuss about blood pressure.
What is blood pressure?
The pressure exerted by the blood against the vessel wall is called blood pressure.
What is blood pressure?
Blood pressure is the pressure exerted by the blood against the vessel wall.
There are some terms in blood pressure.
First, what is systolic blood pressure?
We have heard about systolic and diastolic blood pressure.
Systolic blood pressure is the highest pressure exerted by the arteries in the systolic phase or the phase when the heart contracts.
So, what is systolic blood pressure?
The highest pressure in the artery produced in the heart's contraction or systolic phase is called systolic blood pressure.
The normal value of systolic blood pressure is 120 mmHg.
Next, we have diastolic blood pressure.
Diastolic blood pressure is the lower pressure exerted in the arteries.
The lower pressure exerted in the arteries is called diastolic blood pressure.
Diastolic blood pressure is the lowest pressure exerted in the arteries in the heart's relaxation or diastolic phase.
The normal value of diastolic blood pressure is 80 mmHg.
Next, we have pulse pressure.
Pulse pressure is the difference between systolic and diastolic blood pressure.
The difference between systolic and diastolic pressure is called pulse pressure.
The difference between systolic and diastolic pressure is 80 mmHg.
Next, we have mean blood pressure.
Mean blood pressure is the value of the average pressure added to the diastolic pressure.
The value of mean blood pressure is 96 to 100.
The mean blood pressure is the average pressure added to the diastolic pressure.
These are the terms related to blood pressure.
Systolic, diastolic, pulse pressure and mean blood pressure.
Next, we will discuss about BP measurement.
We can measure BP in different ways.
We can classify BP measurement as indirect method and direct method.
How?
Indirect method and direct method.
Now, we will classify indirect methods in three ways.
The first indirect method is auscultatory method.
It is known as sphygmomanometer.
Sphygmomanometer is used in hospitals to measure blood pressure.
It is an indirect method.
The sound is also used to measure BP.
The internal sound of the body is used to measure the heart beat.
That is why it is called auscultatory method.
The sound of the internal body is also used to measure BP.
That is an indirect method.
The next method is osmometric method.
The next is ultrasonic method.
These are the three indirect methods for measuring BP.
So, these are the osculatory method, osmometric method and ultrasonic method.
Next is the direct method classification.
How do we classify the direct method?
First one is percutaneous insertion.
Percutaneous insertion is a method used to measure blood in the skin.
Next is catheterization and implantation.
These three methods are the direct methods.
Let us see the BP measurement in detail.
Now, let us see the indirect methods.
The first indirect method is auscultatory method.
In this method, the stethoscope and sphygmomanometer are used.
In hospitals, doctors usually use this method.
This is the diagram.
The sphygmomanometer is mainly used in this method.
We all know the procedure.
The sphygmomanometer is placed in the palm of the hand.
There is a valve in the sphygmomanometer.
The valve is opened and the sphygmomanometer is pressed.
When the valve is pressed, the mercury level in the sphygmomanometer rises.
The doctor uses a stethoscope to measure the heart rate.
He adjusts the pressure valve and measures the systolic and diastolic readings.
He then measures the blood pressure.
This is the general procedure for measuring in the case of the auscultatory method.
Let us see the procedure.
The cuff is wrapped around the patient's upper arm.
In the upper arm or biceps, it is called the cuff.
The cuff is wrapped around the patient's upper arm.
The cuff is placed between the elbow and shoulder.
There is an artery in the part where the cuff is wrapped around the patient's upper arm.
This is called the brachial artery.
This is where the stethoscope is placed.
The cuff is placed between the elbow and shoulder.
The stethoscope is placed between the brachial artery.
This is called the brachial artery.
The cuff is placed between the elbow and shoulder.
This is called the brachial artery.
This is where the stethoscope is placed.
The pressure is applied to the cuff.
There is a bladder in the cuff.
When the pressure is applied to the bladder, the cuff is filled with air.
When the pressure is applied to the cuff, the cuff is filled with air.
Doctor, you have understood the systolic pressure as an anticipatory pressure.
Before doing this, make sure you have a rotatory artery in your arms.
He will look at the patient with his finger and when he reaches a particular point,
he will see the pumping there, when the pressure increases.
That value is called Anticipatory Systolic Pressure.
Let's assume that it is at 120.
Then the doctor will press the ball pump a little higher and increase the pressure a little more.
That is, he will run it at a range of 140-150.
Then what will he do?
Then he will place the stethoscope on the brachial artery and the pressure will be reduced slightly.
At this point, above the point where the doctor placed the ball,
no sound will be heard in the stethoscope.
No sound of pumping blood will be heard.
Then the pressure will be reduced slightly.
The Anticipatory Systolic Pressure is 120, right?
When it reaches that value, the sound will be heard.
That is, no sound of pumping blood will be heard.
Then he will hold at that particular point.
He will hold and see.
That reading is called Systolic Pressure.
Okay?
It is called Systolic Pressure.
Then the pressure in the cuff will be reduced slowly.
That is, when it comes down to that point, the sound of pumping blood will be heard smoothly.
Okay?
Then the sound of pumping blood will be heard.
That sound is called Korotkov Sound.
Korotkov Sound.
This sound will be heard.
When this sound is heard,
when it reaches a particular point,
this sound will be seen as standing.
That standing point will be noted later.
That is, the pressure will be reduced and the standing point will be measured.
That is called Diastolic Pressure.
Diastolic Point.
Okay?
That's all.
We will wrap the cuff in our hand.
After wrapping,
the pressure will be inserted into the pump.
When the pressure is inserted,
when the pump is squeezed,
what happens?
The pressure will be inserted into the inflated bladder.
That pressure will be more than the anticipated systolic pressure.
That is, the child will hold his hand and look.
You will get an idea of how much it will be.
He will be holding his hand and squeezing the pump.
When it reaches a particular point,
the child will feel the pulse in his hand.
He will feel the pulse.
So, from the beginning,
the pressure will be set to 20.
After setting,
when the pressure is reduced a little,
the sound will be heard using a stethoscope.
The stethoscope is fixed in the brachial artery.
That is,
when the sound is heard,
it will reach a particular point.
That is, when it reaches 120.
When it reaches a value close to 120,
the sound will be heard.
The sound will be heard.
The systolic pressure is the point at which the sound will be heard.
Then the sound will continue to be smoother.
In this way,
the sound will continue to be heard.
The sound will continue to be heard smoothly.
Then,
the pressure in the cuff will drop and drop.
When it drops and drops,
when it reaches a particular point,
the Korotkov sound
can be seen to disappear again.
At that lower point,
the patient's diastolic pressure
can be seen to disappear.
In the case of a normal man,
the systolic pressure by diastolic
is 120 by 80 mmHg.
When we say systolic pressure by diastolic,
it should be in the ratio of systolic to diastolic.
It should not come back to 80 by 120.
80 to 120 is the level of sugar.
It should never come back.
It is the level of sugar.
When we say pressure,
it should be in the ratio of systolic to diastolic.
So, systolic by diastolic is 120 by 80 mmHg.
The main limitation of this is
that the person who is watching
should have a good hearing.
Otherwise,
when you look with a stethoscope,
the Korotkov sound
starts and disappears.
If you can't hear anything,
the value taken will be wrong.
So, it is highly dependent on
the hearing accuracy
or sharpness of the operator.
So, it is based on the operator.
When we go to a doctor
and go to another doctor,
you may see pressure variations.
That's it.
The main limitation of this is
the hearing accuracy.
Now, we are going to learn
the indirect method,
palpation method,
oscillometric blood pressure measurement,
ultrasonic pressure measurement,
direct method percutaneous insertion,
catheterization,
implantation of a transducer
in the vessel or in the heart.
When these things happen,
the blood flow will end.
We can discuss these things
in the next lecture.
Thanks for watching.
See you in the next lecture.