KTU BIOMEDICAL ENGINEERING || EC365 || MODULE 5 || LECT 26 || X-Ray Imaging
X-Ray Imaging- Properties and production of X Rays, X-Ray machine, application of X-Rays in medicine
For the full video of this course : https://www.youtube.com/playlist?list=PL2UV2EJdMQmh3GlNha5gwN8IsIyjOKcGh
#ktubiomedical #biomedicalengineering #ktu
Hi all, today we are starting our 5th module
These are the contents included in 5th module
The main contents to learn in 5th module is about Medical Imaging Systems
We have to learn X-ray imaging,
Computed Tomography,
or CT Scan,
Computed Tomography,
and Ultrasonic Imaging Systems
These are the contents of 5th module
5th module and 6th module are very important
because 5th module and 6th module are the most important modules
It is very easy, let's move to the portion
When we learn about Medical Imaging Systems,
the most frequently heard term is Radiology
What is Radiology?
It is a special branch that deals with the study and application of image technology
using X-ray radiation or such other radiation devices
for the purpose of obtaining visual information
to diagnose and treatment of diseases
Radiology is a special branch of study
that deals with the application of image technology using X-ray radiation or such other radiation devices
Radiology is a special branch of study that deals with the application of image technology using X-ray radiation or such other radiation devices
Let's look at X-ray imaging
X-rays are generated by high vacuum X-ray diode tube
in which electrons are accelerated to high velocities
using a high power supply up to 100 kV
that is, electrons are flowing
How?
Electrons are flowing at high velocities
that is, electrons are accelerated to high velocities
using a high power supply up to 100 kV
a cathode and an anode operate in this
a cathode is a tungsten filament
a heated tungsten filament acts as a cathode
electrons move from the cathode to the high voltage anode
X-ray tubes operate by emitting electrons from heated cathode tungsten filament
X-rays move towards a rotating high voltage anode disk
X-rays arise from the target disk at right angles
and are focused by the collimator
X-rays are focused by the collimator
Most of the energy is heat
Image intensifier or photomultiplier tubes allow greater viewing contrast
Images received on photographic plate
X-rays are obtained in light and dark areas
Anode is a rotating anode
Radiation intensity can be obtained by varying high voltage, current and time of the exposure
Radiation is filtered and formed to produce optimal contrast relative to the patient dose
Inside the X-ray tube is kept vacuum to ensure the undistributed path for electrons and for long life
This is the block diagram of an X-ray machine
Multitap AC transformer, filament transformer, timing circuit, high voltage transformer
Multitap AC transformer
The number of output is referred to as taps and it may range from two outputs to many outputs depending on the type of multitap transformer used
Multitap AC transformer is used to compensate incoming variations
The number of output is referred to as taps and it may range from two outputs to many outputs depending on the type of multitap transformer used
Multitap transformer has different taps in different voltages
We can select a higher voltage tap or lower voltage tap depending on the intensity of X-ray exposure
This also permits the operator to choose voltages for specific applications
X-ray tube filament transformer
This transformer transforms the AC line to supply power for heating the cathode filament
This power can be selected by taps to change the filament heat which in turn changes the X-ray tube current and total energy delivered to patient
X-ray tube high voltage transformer and bridge rectifier
This block together transforms the AC line to supply the high DC voltage for accelerating electrons from cathode to anode
X-ray tube high voltage transformer and bridge rectifier
This block together transforms the AC line to supply the high DC voltage for accelerating electrons from cathode to anode
Timing circuit
Timing circuit is used to control the turn on, turn off and length of X-ray exposure delivered to the patient
It consists of an electronic counter that applies high voltage to the X-ray tube anode for a short period of time
This is the block diagram explanation of X-ray machine
Let's see the advantages of X-rays in medicine
X-ray can be used to produce an image of any body part
It is also available as a portable unit which can be used in hospitals widely and X-ray can be taken anywhere even bedside
It is less costly when compared to other imaging models like MRI scan
X-ray can produce fast results
It is comparatively easy technique
So these are the advantages of X-rays in medicine
Next we can look what are the applications of X-rays in medicine
X-ray machines are used in healthcare for visualizing bone structures and other dense tissues such as tumours
The two main fields which use X-ray machine are radiography and dentistry
Radiography is used for fast and highly penetrating images
These are the four different applications of X-ray in medicine
That's all about X-ray
I hope everyone understood about X-ray
We have started the 5th module
See you in the next topic