Generator power inlet box and interlock kit install! #452

The Kelley's Country Life
18 followers
Welcome back everybody. My name is Andrew and you're watching the Kelly's Country Life. So I apologize
it is very dark. We are working inside of our pole barn house. Well as you can see that does
not have power. We're nowhere near that point but we've started wiring in our rough-in electrical
for our main panel and everything else in the house and today we're going to address something
that's been an extremely popular question on the channel. So that question's been are you going to
Absolutely. This is Florida. We get hit with hurricanes, tornadoes, all kinds of other stuff
from time to time. So power outages are quite common. We have multiple generators for backup.
Just we've learned our lesson over the years and I've already known that I was going to put
a generator plug to help run the house. I'm going to do things a little different today. One to save
money and two because I don't care for certain ways to install generator plugs. So I'll explain.
So I'm going to be doing a very simplistic kit here. It's basically just a metal slide plate.
It's called a generator interlock kit that will mount to the front of this panel. We'll cover that
in this video and what it basically does is allow me to mount say a generator plug right here. So
let's just say if that's my generator plug right there and it will be what basically what you
cannot have happen. You cannot have your main 200 amp breaker be in the on position while you have
your generator plug on. That is an extremely dangerous situation for the power companies.
A lot of people when they back feed or install generator plugs wrong in panels they have it so
the generator is actually powering this panel up while this main 200 amp breaker can be on
and that creates a very dangerous situation for the simple fact that it can now send power back
out through the power line while the power company is trying to safely work to restore your power.
So you have two options. The option we're going with today is install this generator interlock kit
which is a very thick metal plate that will slide up and allow the generator breaker to be on.
The only way that it can slide up is for the main 200 amp breaker to be in the off position.
So it makes it to where both of these cannot be on at the same time creating again that
electrical shock hazard or dangerous situation for the linemen that are out there working.
So the other option and one I'm not crazy about because it's very expensive is called a generator
transfer switch and it's a box you mount outside on the house you plug in your generator to that
and it will only allow you to run but so many circuits in a panel like this. Now that's kind
of a foolproof way to do it and a way to do it if you are not very familiar with the electrical
side of things and by the way if you're not comfortable with any of this you need to be
having a certified electrician install all this for you. But that interlock kit will only run
but so many circuits whereas what I'm putting in will power up this entire panel. Now that's good
and that's bad. One for the simple fact of my generator cannot power everything in this entire
house so you've got to be mindful of that. Come in here and throw all your other breakers off.
Only power up the necessities that you need while you're in a power outage situation. Otherwise
you're going to trip your generator out there and you're going to constantly overload it.
So there's no point in having every breaker and try to run everything in the house.
It depends on the wattage of your generator what you're going to turn on what you're going to do.
Chances are your generator if you got a small one on wheels like us it's not going to run your
whole house AC. You don't need to be running an electric hot water heater an electric stove
things like that. Those are very power intensive accessories for the house. Now the good news is
because we're doing this pole barn house with thick blown in insulation my HVAC guy thinks
because we're doing a very small central unit with a soft start addition to it he thinks that
my generator is big enough to actually run that. So there is a chance that I can cool down the
house don't need to run anything else while I'm doing that. We'll find out down the road if we'll
run it then I can cut the main AC off and our generator is plenty big enough it's almost 10,000
watts we can run anything else in the house that we want since we're doing propane accessories.
So but TVs appliances all that stuff you're talking to minimal wattage there. So the plug I'm
going to install today is a 30 amp plug depending on the size of your generator you may install a
50 amp service but I have set this up in a way that I can swap that out easily in the future
even with insulation on the wall pull a heavier gauge wire put a 50 amp receptacle on the outside
for that generator. So keep that in mind as you're watching what I'm doing this is set up for me to
change down the road should we get a bit of bigger generator but as of right now I just don't think
we are going to get a bigger one especially if this will wind up running AC as well this will
cover anything we can ever need in a power outage situation. So I'm going to be mounting this
decorative box on the outside of the house to make it real easy for my left side to trim around.
Here's my generator plug box I'm actually going to mount this to this panel right here and this
also leaves me room to come in this panel down the road to pull a phone line in the house
should we ever wind up getting internet out here. All this will come pulling right in beneath the
main panel I'm going to have a door here down the road so I can easily access that's why it'll be
very easy for me to change this out to a 50 amp plug 50 amp wire down the road if I ever need to
plus this panel right here gives me outside access for things like that phone line.
So let me get my uh figure out where I want to mount this get my wire run through the side of
the house we'll go mount this outside seal everything up I'll show you the other reason
why I use this and we'll get the wire pulled up into the panel figure out exactly where we're
going to mount our breaker and then I'll show you how to install that interlock kit on the
breaker panel door if that is so.
So I've actually purchased a three conductor wire because that's what a lot of these plugs
actually require you see it's got four prongs so it's three conductors plus a ground what you get
in a three conductor wire like this. I've also run conduit that's big enough for me to upgrade to
a six gauge wire down the road and actually pull through here if I ever go up to 50 amps of service
so whenever I mentioned our generator wattage earlier that was peak starting watts but continuous
watts and the amperage output on it it's only got a 30 amp output which is quite common of an
output for generators of the size that we have right there. So such a short uh run of wire right
here this uh particular 10 gauge wire right here is rated for 30 amps but if you're going to run
any higher than that it does not hurt to go ahead and go to the next size up eight gauge or even
go on to six gauge just didn't have any so I'm going with the 10 that I do have like I said uh
it should be fine for the two to three foot run of wire that we have right here. So it's very easy
this generator plug has a red as you can see when you get a three conductor wire you get a red
has a white which we also have um it's got a hook up right here for our black hot and then our ground
actually hooks up inside of this panel right here to this ground it's got a clamp in here I'll show
you in just a second where we'll clamp those two together then we'll wire all that up in the panel
a little bit later down the road I can't do that right now but I will show you on this video how
that will be done. All right so as you can see now I have the three colors hooked up to the color
codes on the back side of the plug and the generator plug ground is hooked to the ground
coming out of the wire out of the wall where it'll be grounded inside of the panel so a very
straightforward hookup. So anytime you run a new wire into one of your panels you actually have to
clamp it so you'll knock out one of these metal knockouts out of the bottom for the appropriate
size clamp I'm using a three quarter inch clamp for this size wire right here you'll insert this
and then we'll run our wire through it and that's how we'll clamp it.
All right now we'll run this wire up and through that knockout and code also requires that you nail
this wire within 12 inches of the outside of that panel using a wire staple.
All right so I've stripped the insulation back to make it easier to fit everything in the panel
now we're at the rough end stage of our house right now so there's no power to this panel
nothing to actually connect until I pass my rough end electrical inspection but we can go ahead and
talk about how you hook this up in case you're watching for that. So since I have four wires
coming out of my four wire connector and there's four wires that also come off of the generator
itself you'll have your ground wire your neutral wire and your two hot wires which is your red
and black this is what will actually bring two separate 110 volts or 220 depending on which way
you look at it inside and then here is a common neutral that they will use. All right so if we
were actually going to hook this up right now because this is the first panel or first disconnect
in my system as in this is not a sub panel this is not feeding off of another panel I will actually
be putting a bonding screw in up here and it means this bar right here these neutral bars
on both sides are also going to be your ground bars so you would hook up your white and your
ground to this bar now if this was a sub panel I would have that bonding screw out you would have
a separate ground bar over here on the side and you'd have your neutral bar your ground would go
to that separate bar on your sub panel your white would go to your neutral bar as it does in this
panel right here so that's the difference between a main panel and sub panel you actually have to
separate out your neutrals and grounds whereas your first panel in the system like this right
here which is what the majority of people probably will be hooking up to you will combine both of
those then that would leave you left with your white and black which you hook into your generator
plug either side does not matter so ultimately that's how it would be these two hooked right in
here and that's how it will be down the road once we pass our roughing inspection and these two wires
hooked into any one of these screws on our neutral bar now I'll actually take a piece of the
insulation that I stripped off slide it back over all my wires and label this generator that way I
know what is in this panel for down the road now we're about to install the interlock kit and I am
99% sure the plug your generator plug will have to go in the top right section of your panel for
this kit to work we're about to look at the instructions and check that out but it's critical
that you use this location so if you already had a plug here for example the wires hooked up
feeding something else in your house what you would actually have to do is remove that
and find a different spot on the panel to snap it into but this spot has to be for the generator plug
up top right here all right so this is how our interlock kit comes right here it's very simple
it's quite expensive for no more than it is but much cheaper than doing a full transfer switch
now you have to buy these specifically for the type of panel that you have I'm using a
Homeline 200 amp indoor panel these will vary based off the panel that you have
all right so this looks very straightforward it's uh it's got a picture to show the correct
direction to put this in and yes we will be using the top plug as the generator plug as I
had imagined and this looks to be properly spaced for the bar that's right here
so we will line this up as the picture shows it says to drill three holes with the provided
drill bit and put this together place this bar over first then the actual interlock slide bar
and then these cap headed kind of nuts right there but before we put those in we use some
of this thread locker right here all right so now our generator interlock plate is in there
it slides freely just like we want so we can go put this panel on the main breaker panel and verify
that the main breaker cannot be turned on if the generator plug is in the on position
all right so I have my panel loosely on because again you know we have to pass rough inspection
we're at that point yet but I'm checking fit of our interlock kit so it come with stickers to label
that this is a generator plug also come with a caution and warning sticker saying where the
generator hook up or should be and it also comes with some codes and guidelines that's a nice
sticker to have right there for the national electric code and a few other things as well to
show that this is a compatible kit right here so what you can't see is this is off position on my
breaker it says off right here on over here and right now I have the generator flipped up to the
on position so if we were in a power outage situation right now it would be supplying power
to this panel but as you can see I cannot flip on the main breaker right here because this is in the
so if I were to flip off the generator this drops down now I can supply power back to the house
so this interlock keeps both of these from being on at the same time and again
causing that dangerous situation all right well hopefully you enjoyed that little install this is
something I had to get done and installed before we get spray foam insulation blown in the wall
need to go ahead and get that penetration through fire hooked up so if you're interested in these
type of videos don't forget it'll thumbs up subscribe to the channel and you can continue
to watch this I'm filming everything as I build this pole barn house right here as soon as we
pass rough in electrical inspections we'll move on toward sheetrock and insulation and ultimately
getting back to wiring this panel up inserting all our breakers and doing our final electrical
installation and hookup of everything in the house so like I said if you're interested in that
we would appreciate you subscribing to the channel and watching along catch on the next video