Learn about the importance of partial discharge testing (PD testing) on power transformers. Partial discharge is a major cause and reliable indication of developing insulation defects in power transformer bushings and windings, which can cause their eventual failure and costly outages. PD testing is an effective diagnosis method used to detect and localize insulation defects and to evaluate the overall insulation condition and risk of failure in power transformers during factory testing, site acceptance testing (commissioning), as well as in-service troubleshooting for effective maintenance planning. For highly reliable, industry-standard PD testing on power transformers, OMICRON recommends the MPD 800 universal partial discharge measurement and analysis system. ☝️ Learn more about MPD 800 on our website: http://www.omicronenergy.com/mpd800 ☝️ Learn more about PD testing on our website: http://www.omicronenergy.com/pd-testing ▶️Interested in PD testing? – Watch all of our videos: https://youtube.com/playlist?list=PLzmbZeI1bhu9mO5Qrk0VFLbixTlET0gkO _ Would you like to find out more about OMICRON, our passions, and our products? 🌐Check out our website: https://www.omicronenergy.com/en Or follow us on social media: 👉On LinkedIn: https://www.linkedin.com/company/omicron-electronics/ 👉On our podcast Energy Talks: https://www.omicronenergy.com/en/energy-talks-podcast/ 👉On YouTube: https://www.youtube.com/channel/UC2F35zz5XMoi1vbXrMgEyGQ
In Part 1 of our video series titled Essentials of Partial Discharge Testing, Caspar Steineke, partial discharge (PD) expert and co-creator of OMICRON MPD technology, discusses the importance of knowing the insulation condition of electrical assets, how partial discharge plays a role in insulation deterioration and eventual failure, why regular PD testing is the preferred method for insulation condition assessment, and how PD testing provides users with the information they need to plan effective timely action to prevent equipment failure and costly outages. 00:00 - Introduction 00:14 - Why is insulation condition critical to know? 00:46 - What are partial discharges? 01:21 - What does PD activity indicate? 01:50 - Why should you perform PD measurements? 02:27 - How are PD measurements non-destructive? 02:45 - Conclusion and contact information Partial discharge (PD) is a reliable indicator and major cause of deterioration in electrical insulation which can result in equipment failure and costly outages. Regular PD testing is a non-destructive and highly reliable method for assessing the insulation condition of electrical equipment, and it provides users with vital information to plan timely action that ensures their continued reliability and availability. ▶️ Watch our other videos in this series: https://www.youtube.com/playlist?list=PLzmbZeI1bhu_LzQMX-rrNUifPHMvhRUFW ☝️ Learn more about PD testing on our website: https://www.omicronenergy.com/pd-testing _ Would you like to find out more about OMICRON, our passions, and our products? 🌐Check out our website: https://www.omicronenergy.com/en Or follow us on social media: 👉On LinkedIn: https://www.linkedin.com/company/omicron-electronics 👉On our podcast Energy Talks: https://www.omicronenergy.com/en/energy-talks-podcast/ 👉On YouTube: https://www.youtube.com/channel/UC2F35zz5XMoi1vbXrMgEyGQ
In Part 2 of our video series titled Essentials of Partial Discharge Testing, Caspar Steineke, partial discharge (PD) expert and co-creator of OMICRON MPD technology, discusses when it is important to perform PD testing on electrical assets to verify their insulation condition and detect defects and deterioration to assess the risk of potential failure and costly outages. He also emphasizes the importance of performing regular PD testing on electrical equipment to identify changes in potentially damaging PD activity by comparing the results of previous and successive PD measurements. 00:00 - Introduction 00:14 - When are PD measurements performed? 01:18 - What is the benefit of repeated measurements? 01:54 - Conclusion and contact information Partial discharge (PD) is a reliable indicator and major cause of deterioration in electrical insulation which can result in equipment failure and costly outages. Regular PD testing is a non-destructive and highly reliable method for assessing the insulation condition of electrical equipment, and it provides users with vital information to plan timely action that ensures their continued reliability and availability. ▶️ Watch our other videos in this series: https://www.youtube.com/playlist?list=PLzmbZeI1bhu_LzQMX-rrNUifPHMvhRUFW ☝️ Learn more about PD testing on our website: https://www.omicronenergy.com/pd-testing _ Would you like to find out more about OMICRON, our passions, and our products? 🌐Check out our website: https://www.omicronenergy.com/en Or follow us on social media: 👉On LinkedIn: https://www.linkedin.com/company/omicron-electronics 👉On our podcast Energy Talks: https://www.omicronenergy.com/en/energy-talks-podcast/ 👉On YouTube: https://www.youtube.com/channel/UC2F35zz5XMoi1vbXrMgEyGQ
In Part 3 of our video series titled Essentials of Partial Discharge Testing, Caspar Steineke, partial discharge (PD) expert and co-creator of OMICRON MPD technology, describes the various methods used to detect and measure potentially failure-causing PD activity in electrical equipment. He also explains when offline and online PD testing is performed and highlights the time-saving advantages of performing multi-channel PD measurements for more complete assessments of insulation condition in electrical equipment. Lastly, he describes which international standards are applied to guide in the setup and performance of PD measurements on electrical assets. 00:00 - Introduction 00:12 - How is PD detected and measured? 01:09 - What equipment is required? 01:42 - When are offline and online measurements performed? 02:32 - What is the advantage of multi-channel measurements? 03:23 - Which international standards apply? 03:56 - Conclusion and contact information Partial discharge (PD) is a reliable indicator and major cause of deterioration in electrical insulation which can result in equipment failure and costly outages. Regular PD testing is a non-destructive and highly reliable method for assessing the insulation condition of electrical equipment, and it provides users with vital information to plan timely action that ensures their continued reliability and availability. ▶️ Watch our other videos in this series: https://www.youtube.com/playlist?list=PLzmbZeI1bhu_LzQMX-rrNUifPHMvhRUFW ☝️ Learn more about PD testing on our website: https://www.omicronenergy.com/pd-testing _ Would you like to find out more about OMICRON, our passions, and our products? 🌐Check out our website: https://www.omicronenergy.com/en Or follow us on social media: 👉On LinkedIn: https://www.linkedin.com/company/omicron-electronics 👉On our podcast Energy Talks: https://www.omicronenergy.com/en/energy-talks-podcast/ 👉On YouTube: https://www.youtube.com/channel/UC2F35zz5XMoi1vbXrMgEyGQ
In Part 4 of our video series titled Essentials of Partial Discharge Testing, Caspar Steineke, partial discharge (PD) expert and co-creator of OMICRON MPD technology, discusses how disturbances, namely external noise typical in many onsite and offsite testing environments, can compromise the reliability of PD measurement data. He describes the various methods and source separation techniques used to reliably minimize or even eliminate the effects of external noise to enable highly accurate PD measurements, as well as the reliable analysis and interpretation of PD measurement data. 00:00 - Introduction 00:14 - How does external noise affect PD measurements? 00:43 - How can you minimize the effects of external noise? 02:12 - What tools are used for PD source separation? 03:15 - Conclusion and contact information Partial discharge (PD) is a reliable indicator and major cause of deterioration in electrical insulation which can result in equipment failure and costly outages. Regular PD testing is a non-destructive and highly reliable method for assessing the insulation condition of electrical equipment, and it provides users with vital information to plan timely action that ensures their continued reliability and availability. ▶️ Watch our other videos in this series: https://www.youtube.com/playlist?list=PLzmbZeI1bhu_LzQMX-rrNUifPHMvhRUFW ☝️ Learn more about PD testing on our website: https://www.omicronenergy.com/pd-testing _ Would you like to find out more about OMICRON, our passions, and our products? 🌐Check out our website: https://www.omicronenergy.com/en Or follow us on social media: 👉On LinkedIn: https://www.linkedin.com/company/omicron-electronics 👉On our podcast Energy Talks: https://www.omicronenergy.com/en/energy-talks-podcast/ 👉On YouTube: https://www.youtube.com/channel/UC2F35zz5XMoi1vbXrMgEyGQ
In Part 5 of our video series titled Essentials of Partial Discharge Testing, Caspar Steineke, partial discharge (PD) expert and co-creator of OMICRON MPD technology, describes how PD data is analyzed and interpreted and explains that expert knowledge is not necessarily required to determine whether detected PD activity is harming the insulation of electrical equipment to cause eventual failure. He describes what level of PD activity is tolerable in various types of electrical equipment and when immediate investigation and remedial action is required to prevent insulation failure and costly outages. 00:00 - Introduction 00:14 - How much experience is required for PD analysis? 00:45 - How do you analyze PD data? 01:46 - What levels of PD are tolerable? 02:37 - Conclusion and contact information Partial discharge (PD) is a reliable indicator and major cause of deterioration in electrical insulation which can result in equipment failure and costly outages. Regular PD testing is a non-destructive and highly reliable method for assessing the insulation condition of electrical equipment, and it provides users with vital information to plan timely action that ensures their continued reliability and availability. ▶️ Watch our other videos in this series: https://www.youtube.com/playlist?list=PLzmbZeI1bhu_LzQMX-rrNUifPHMvhRUFW ☝️ Learn more about PD testing on our website: https://www.omicronenergy.com/pd-testing _ Would you like to find out more about OMICRON, our passions, and our products? 🌐Check out our website: https://www.omicronenergy.com/en Or follow us on social media: 👉On LinkedIn: https://www.linkedin.com/company/omicron-electronics 👉On our podcast Energy Talks: https://www.omicronenergy.com/en/energy-talks-podcast/ 👉On YouTube: https://www.youtube.com/channel/UC2F35zz5XMoi1vbXrMgEyGQ
MONTESTO 200 is a portable solution that enables you to perform temporary online partial discharge (PD) monitoring. You can use the IP65-rated solution both indoors and outdoors on various medium-voltage and high-voltage electrical assets under load to trend PD activity and assess insulation condition. Automated software features enable users to quickly and reliably identify signal sources. PD activity is a reliable indicator of insulation condition, as it is often a sign of insulation defects that can potentially cause failure in electrical assets. 00:00 - Introducing MONTESTO 200 00:50 - On-line PD measurement 01:20 - On-line PD monitoring ☝️ Learn more about MONTESTO 200 on our website: https://www.omicronenergy.com/montesto200 ▶️Interested in PD testing? – Watch all of our videos: https://www.youtube.com/playlist?list=PLA4B13E71E3A2DF13 _ Would you like to find out more about OMICRON, our passions, and our products? 🌐Check out our website: https://www.omicronenergy.com/en Or follow us on social media: 👉On LinkedIn: https://www.linkedin.com/company/omicron-electronics 👉On our podcast Energy Talks: https://www.omicronenergy.com/en/energy-talks-podcast/ 👉On YouTube: https://www.youtube.com/channel/UC2F35zz5XMoi1vbXrMgEyGQ
OMICRON’s UHF 800 system ensures sensitive partial discharge measurements on gas-insulated switchgear (GIS). This video shows you how the UHF 800 PD measurement and analysis system is easily set up and used on GIS. UHF 800 measures PD in the ultra-high frequency (UHF) range from 100 to 2000 MHz to greatly minimize or eliminate interference from external noise in the testing environment – this is especially beneficial during onsite PD measurements. UHF 800 can be used for single-channel or synchronous multi-channel offline and online UHF PD testing on GIS. Conventional on-site PD measurements, such as those specified by the IEC 60270 standard for high-voltage acceptance testing and troubleshooting, are challenging since they are often affected by noise in the surrounding environment. By comparison, PD measurements performed in the UHF range result in a very high signal-to-noise ratio to enable reliable measurement and analysis. This is because numerous sources of noise, such as mobile communications, radar and corona discharges, are transmitted predominantly in lower or quite narrow frequency ranges. UHF PD measurements in GIS therefore ensure optimal sensitivity with little or no interference from external noise. OMICRON’s UHF 800 system can also be used for sensitive UHF PD measurements on oil-filled power transformers and high-voltage power cable terminations. ☝️ Learn more about UHF 800 on our website: http://www.omicronenergy.com/uhf800 ☝️ Learn more about PD testing on our website: http://www.omicronenergy.com/pd-testing ▶️Interested in PD testing? – Watch all of our videos: https://youtube.com/playlist?list=PLA4B13E71E3A2DF13 _ Would you like to find out more about OMICRON, our passions, and our products? 🌐Check out our website: https://www.omicronenergy.com/en Or follow us on social media 👉On LinkedIn: https://www.linkedin.com/company/omicron-electronics/ 👉On our podcast Energy Talks: https://www.omicronenergy.com/en/energy-talks-podcast/ 👉On YouTube: https://www.youtube.com/channel/UC2F35zz5XMoi1vbXrMgEyGQ
Learn about the importance of partial discharge testing (PD testing) on rotating electrical machines, such as generators and electrical motors. Partial discharge is a major cause and reliable indication of developing insulation defects in the stator windings of motors and generators, which can cause their eventual failure and costly outages. PD testing is an effective diagnosis method used to detect and localize insulation defects and to evaluate the overall insulation condition and risk of failure in rotating electrical machines during factory testing, site acceptance testing (commissioning), as well as in-service troubleshooting for effective maintenance planning. For highly reliable, industry-standard PD testing on motors and generators, OMICRON recommends the MPD 800 universal partial discharge measurement and analysis system. ☝️ Learn more about MPD 800 on our website: http://www.omicronenergy.com/mpd800 ☝️ Learn more about PD testing on our website: http://www.omicronenergy.com/pd-testing ▶️Interested in PD testing? – Watch all of our videos: https://youtube.com/playlist?list=PLzmbZeI1bhu9mO5Qrk0VFLbixTlET0gkO _ Would you like to find out more about OMICRON, our passions, and our products? 🌐Check out our website: https://www.omicronenergy.com/en Or follow us on social media: 👉On LinkedIn: https://www.linkedin.com/company/omicron-electronics/ 👉On our podcast Energy Talks: https://www.omicronenergy.com/en/energy-talks-podcast/ 👉On YouTube: https://www.youtube.com/channel/UC2F35zz5XMoi1vbXrMgEyGQ
Learn about the importance of partial discharge testing (PD testing) on medium-voltage (MV) and high-voltage (HV) electrical power cables. Partial discharge is a major cause and reliable indication of developing insulation defects in power cables, including power cable joints and terminations, which can cause their eventual failure and costly outages. PD testing is an effective diagnosis method used to detect and localize insulation defects and to evaluate the overall insulation condition and risk of failure in power cables during factory testing, site acceptance testing (commissioning), as well as in-service troubleshooting for effective maintenance planning. For highly reliable, industry-standard PD testing on power cables, OMICRON recommends the MPD 800 universal partial discharge measurement and analysis system. ☝️ Learn more about MPD 800 on our website: http://www.omicronenergy.com/mpd800 ☝️ Learn more about PD testing on our website: http://www.omicronenergy.com/pd-testing ▶️Interested in PD testing? – Watch all of our videos: https://youtube.com/playlist?list=PLzmbZeI1bhu9mO5Qrk0VFLbixTlET0gkO _ Would you like to find out more about OMICRON, our passions, and our products? 🌐Check out our website: https://www.omicronenergy.com/en Or follow us on social media 👉On LinkedIn: https://www.linkedin.com/company/omicron-electronics/ 👉On our podcast Energy Talks: https://www.omicronenergy.com/en/energy-talks-podcast/ 👉On YouTube: https://www.youtube.com/channel/UC2F35zz5XMoi1vbXrMgEyGQ
When MPD technology joined the OMICRON portfolio in 2006, it was already a market-proven solution for partial discharge (PD) measurement and analysis. Development of the innovative MPD technology we know today began 20 years ago. Innovative MPD features developed over the years for highly sensitive and reliable PD testing include fiber optic connections of hardware components for safe operation and reduced connection-related disturbances; PD data recording in the field for replay and post-analysis back in the office; as well as advanced methods for eliminating measurement disturbances in noisy environments for highly accurate PD analysis. These features are the basis of MPD technology and continue to make it a leading solution on the market. OMICRON continues to develop and evolve MPD technology to adapt it to an increasing array of PD measurement applications. Partial discharge is a major cause and reliable indication of developing insulation defects in electrical equipment, which can cause their eventual failure and costly outages. ☝️ Learn more about MPD 800 on our website: http://www.omicronenergy.com/mpd800 ☝️ Learn more about PD testing on our website: http://www.omicronenergy.com/pd-testing ▶️Interested in PD testing? – Watch all of our videos: https://youtube.com/playlist?list=PLzmbZeI1bhu9mO5Qrk0VFLbixTlET0gkO _ Would you like to find out more about OMICRON, our passions, and our products? 🌐Check out our website: https://www.omicronenergy.com/en Or follow us on social media 👉On LinkedIn: https://www.linkedin.com/company/omicron-electronics/ 👉On our podcast Energy Talks: https://www.omicronenergy.com/en/energy-talks-podcast/ 👉On YouTube: https://www.youtube.com/channel/UC2F35zz5XMoi1vbXrMgEyGQ
Meet the MPD 800 universal partial discharge (PD) measurement and analysis system, the next generation of the widely-used and innovative MPD PD testing technology from OMICRON. Advanced hardware and software features ensure highly-sensitive single- or multi-channel PD measurements for reliable, industry-standard PD testing on power transformers, rotating electrical machines (motors and generators), power cables, instrument transformers, switchgear, industrial drives and electrical components. The configurable, multi-language MPD 800 software allows you to select only the PD measurement and analysis features you need for specific PD tests and individualized reporting. Powerful noise suppression and PD source separation techniques ensure reliable PD analysis in areas with high levels of interference. The MPD 800 PD testing system accurately detects and localizes insulation defects and helps you to assess the risk of failure in electrical equipment during research and development, factory testing, site acceptance testing (commissioning), as well as in-service troubleshooting for effective maintenance planning. ☝️ Learn more about MPD 800 on our website: http://www.omicronenergy.com/mpd800 ☝️ Learn more about PD testing on our website: http://www.omicronenergy.com/pd-testing ▶️Interested in PD testing? – Watch all of our videos: https://youtube.com/playlist?list=PLzmbZeI1bhu9mO5Qrk0VFLbixTlET0gkO _ Would you like to find out more about OMICRON, our passions, and our products? 🌐Check out our website: https://www.omicronenergy.com/en Or follow us on social media 👉On LinkedIn: https://www.linkedin.com/company/omicron-electronics/ 👉On our podcast Energy Talks: https://www.omicronenergy.com/en/energy-talks-podcast/ 👉On YouTube: https://www.youtube.com/channel/UC2F35zz5XMoi1vbXrMgEyGQ