Hello everyone, I'm Rodrigo from
refrigeration courses, everyone,
welcome to another video here on the
channel, guys, as you can see here
today, we have the LG
inverter machine which is not producing any performance,
what happens is the equipment works it
cools, but it doesn't cool properly, it
doesn't give the performance it needs and
we went downstairs and did some
inflation tests that I'm going to put here
now for you to see, well here, as you
can see, we're doing an
inflation test, right?
Looking at the performance of the equipment, we have
a thermometer, you know, a sensor at the
air inlet of the equipment and a sensor at the
air outlet, here we measure the
ambient temperature, the temperature of the air that is
entering and the temperature of the air that is
leaving, here on the thermometer T1 we
have the air inlet temperature T2 we
have the air outlet temperature
here we have something close to 11º
11 P1 fluctuates a little bit differently
this personal temperature already indicates to
us that the equipment is
cooling, yes, but with low
efficiency, well, we should have a
slightly greater difference so that the
equipment could remove a little
more heat from the ambient air, and
after this test we
determined that the problem could
be here in the
condenser and what do we
When we arrived here at the
condenser, we were able to
see that its fan motor
was running very slowly, we
could almost count the number of
times it ran, so we're going to
open the casing, right, the
equipment fairing here so we can
identify it. If it's a
bldc motor or if it's a capacitor, if it's a
capacitor, it's probably a
weak capacitor, if it's a bldc motor, the problem
could be in one of the
capacitor sensors. Okay, so let's go to the video,
guys, open machine, its capacitor
has already been replaced a few times,
probably this one has already It's a
new capacitor and it's bad, so they've already
left it here, making it easier to change,
these are the two terminals, generally this
type of equipment and its capacitor
is stuck below the board here, great
Rodrigo, how do I know that the fan motor
has a capacitor and not BL on top? here, on
its label, it's already showing
us there, you can see the
1.5 capacitor here, guys. So, a very
simple way for us
to identify it now here, guys. In this case,
we're going to carry out the test, this is the
capacitor that was in the equipment and
this is the capacitor that we already brought
to make the replacement, guys,
now so we're going to carry out the
axima capacitor test here PR,
personal capacitor test, only with a
capacimeter, here we go, as the capacitor
is 1.5, right, 1.5, we're going to test It's
on a scale of two and then it's supposed to
appear here 1.5 1500, okay, we come
here, there's no side, but you can't
forget to discharge the capacitor, if
it has a stored charge, it will
burn your device, so to
discharge it, it's very simple. just
touch it from one to the other and it will
discharge so here we can
see that it was PR it is giving 1500 it is only giving
554 so in a basic calculation here it has
1/3 of the
capacity new capacitor that we
will put in
place Oh,
15505, you see the difference, so what
happens, guys? In general, a capacitor
with 1/3 of its power, right? there
is no heat exchange in the
condenser pressure will rise certain
inverter equipment is able to
know that this pressure has increased reduce the
frequency to try to reduce the
pressure also with this you end up losing
performance beauty good guys so
now equipment properly assembled
we are going to put it to work Go down there and
do the ensu Flamento test and we'll be
right back to do that B nice chat good
guys now equipment
working perfectly, right capacitor
replaced Let's repeat the inflation test then
air temperature that
is entering the equipment at 29.9
temperature that is leaving A 12.4 so
here, if I'm not too bad, I can count something
around 17 degrees of difference between
the temperature that is entering the
equipment and the temperature of the air that
is leaving the equipment, here we
have the equipment that is performing
perfectly, good people like you
saw the equipment, it had a
performance, you know, a significant improvement
and this type of situation guys, when
we don't have the knowledge, is what
distinguishes those who are really prepared
to provide maintenance and those who only know how to do
beauty installation and that's my
invitation, do you want to join us? become a
qualified professional to truly
be prepared to deal with this type
of situation and any other situation that may arise, we
have complete training for
you, it's called the air
conditioning formula, top of the line training
100% online with the right to a
chat group certificate - chat on Telegram with the
other students and as a gift you also get the
error code book, more than 10,000
codes from the most varied brands on the
Brazilian market and
easy payment guys, so don't waste time,
come and become a
qualified professional. The link is below in the
description of the video, the name of the training, the
air conditioning formula and there's one more
message here guys, did you like seeing the
equipment we used, the
capacimeter and the mip thermometer and everything
else you can find there at Temperfrigo, I'll
also leave their link here
contacts telephone e-mail everything is correct
so that you can get in
touch with this company if you wish to
purchase some of the tools that
we used here, great and don't
forget to follow us on our
social networks,
those who follow me here already know if there are
any If you have any questions, leave them below in the
comments and as soon as possible
we will make a new video for you
and don't forget, guys, follow us
on our social networks for today,
just stay with God everyone and see you next time