20 amps
on one leg
and 40 amps
on the
other.
I hear it
clicking
in here.
Looks like
somebody
has
completely
redone that.
But they
don't have,
they don't have
the blower
relay set up to
handle electric heat.
I'll try to show you what I mean.
This right here, this black wire is right
here on this side and that gives you power all
the time but what we need is power over here
run to the
normally
closed
and i'll bring
on the blower
okay this whole
thing is wired
incorrectly for the heat strips oh
yeah i'm gonna get y'all set up
in here this wire should be going
here and this wire should be going
there all right let's start making
changes all right i just need
make sure one more time we don't
have power nothing nothing all right
your heat strip has to
have 240
volts and
whoever
wired
this up
did not
exactly
understand
how they
work
probably
heat
strips will work but how about
the fan and as y'all see this
black wire right here that black
wire right there goes over here
this is going to be my common
and they're feeding blue with it and
this is going
to be my run it's got power all
the time over here on the blower relay
that common is broken and closes when there's
a call on green all right over here we got green
green and common from my low voltage this is normally closed
and this is normally open
and this is from a blower so we need to run
a power wire from here to here all right what i'm
doing is um when this is energized that's
for your heat strips i wish the guy that was that
wired this up was here you see it i've got it
on the same leg that is normally open with this one
right here so this is going
to be all normally closed that way
the blower will come on when the
heat strips are energized the fact you know some
of these may have been energized before but let's
see um let's see how it does now i'll walk right past
this and don't realize that the hole is right
ever all right the blower came
on was the last guy to come out here
um is he really young or
this is
what i'm
looking
for that's
what we
call a
teardrop
fusible
link
there are
others
here's
one that's round these are for those wiring
heat strips and these are some look round ones
that connect directly to the heat strip itself
and i'll tell you when i read across the
the one that's bad in there it read 120 volts normally
if it's bad it's going to read a 240
volts but um hold on but i was getting
100 yeah it said it would read 120 volts
when i tested
across it it should read zero normally if it's bad they read 240
so um let's see if this remedies
my
problem
no power
all right
we got us
a new
sequencer
in there
i mean
excuse me
fusible
link
Let's check
it again.
I'm still
on 20 amps.
That
one's now
pulling 20.
That's what
I'm looking
for y'all
seeing
what I'm
seeing
here?
Amps
on
one
leg
and
40
amps
on
the
other.
I've
got
20
amps
on
one
side
and
40
amps
on
the
other.
Strips are getting 240 volts.
The way you measure that,
you measure from here to here.
You're getting 240
volts across your
heat strip and it's
not pulling amps.
amps i'm talking at the very terminals on the end
then you have a broken heat strip i'm not pulling
amps on this side but i am on this side just a second just a second ago
y'all saw me checking
from the cabinet to a ground
because i'm thinking that this heat strip
is somehow shorted to ground
in there yeah there's something wrong in there
i'm gonna try to see if i can see it i'm a little
bit hesitant to take this out
because sometimes they have a rack for the heat strips to be
suspended in between and then there's a piece
of metal that sticks out the end that goes in a tiny
little hole
and it's it can
be hard to i
say it it can
be hard to hit
the hole there's
that piece
i was telling you about and back there if you
can see it hit the hole let's take this outside
get a better look at it now i see it
that one's broken yeah that one's broken
so that's why i
wasn't getting any amps
over here on this one
but why was it getting why
was it pulling 40 amps on
this side I
do not understand we know
he needs at least one
these all seem
to be in decent shape
you got to be real careful with those things sometimes
these brackets are rusted through
and these little pieces in here are really fragile
y'all will see there's a chance I could
break one of them when I restring it let me contact the owner
and see what he wants to do
I'm trying to call
the owner right
now all right
I had to leave
a message I have
texted him and I
have left him a message I mean I've
already got one of these on here
that's the one I'm working
on and i have an outstanding invoice on that one
so i'm not um i'm gonna wait until i get
approval all right i did get approval
so we are on our way to go pick up a couple of
small
diameter
5kW heat
strips
here we
go i
don't
see any
here's
the
here's
the
large
diameter
one
you'll see the difference
in those take one of those two hold
on all right this requires um
reusing the ceramic that's there i'm gonna take
it anyway all right guys first order what i do
with these is um first order what i
do with these is i i basically cut them then we undo these little
screws and it looks like with um with these that's
exactly what i need it's already soldered to the
screw and i have replacement porcelain
um but getting them the right length that's the hard
part let's get to it you do not want to damage
these porcelain pieces because i may not be able
to find any more of those all
right this pulled out all right
i'm back you let me keep this
that was
real
nice
arm's
length
for me
i can
um i can
adjust
a
little
bit at
a time
once i
get it
in here trying to make sure
that oh it comes with
a little fusible link
so this is how this goes
this in here there there's a little
square piece that fits down
in the square hole right there
put your
washer on it
and then
the nut hold
on you put
this on the
old nut
that has the
lock washer built
into it does not want
to turn like
the threads are a
little bit buggered
stretch this
normally
do them at
arm's length
and my arms
are about
just a little
over six feet
i'll be honest i'm
a little bit surprised
at how good a shape
this porcelain is in
I'm
stretching
it a
little
bit
more
to
do a
little
bit
of
more
a
little
bit
more
stretching
It looks like I'm gonna
fast forward through
the second one
I just want to show
y'all how to do one of these
I do realize
that if I'm
blocking the sun
and y'all might not
be able to see that
Alright that worked out pretty good
Again how
to do these
this piece
goes right
here
And if y'all can see there's a square hole right there
Use this square
hole get you
a washer get
your wire
on this is 1130
seconds
that's good so that's
one heat strip
obviously you want
to make sure
that it's
not touching any
metal anywhere and when you string the other one you want
to make sure that it's not touching the
other one all right
this is what i ended up
with you see how this piece
sticks out just a little
bit so we're
gonna the
cabinet's gonna
be right here
it's touching
anywhere see
how my pieces
ended up right here that's
the way they should look all right let's get ready to go back and
install that
We are back. Do y'all see that little hole
in the back of the cabinet back there?
I got to ring
that with this right here.
Of course,
you don't want to damage
Anything you can't pull these wires out the way
Alright,
alright,
let's
get
this
wired
back
up
one
of
these
goes
here
these
goes
Y'all see
me pressing
on the top of
that that is to
Give it some stability. You don't want to tear it apart.
I do the same thing with sequencers
Let's try
this
again.
Oh,
it
is
smelling.
Wow.
That's another happy customer.
She has dependable heat.
Yeah, it kind of had me perplexed there when I was getting
40 amps on one side and 20 on the other.
It must have been touching
maybe the other heat strip or something.
Had to have done that.
Thanks for watching guys, and I'll catch you on the next one.