In today’s video, I go back to a mobile home where I had previously diagnosed a very dirty evaporator coil. I pump the system down, pull the evaporator and clean it in the yard with chemicals. I did reinstall Paul vacuum and properly charge the system. I show the entire process and how to do it as easily and as efficiently as possible. I hope you enjoy. 
Good morning guys, I'm at a mobile home today
and we are pulling and cleaning an
evaporator coil, this right here, from that it should
be obvious why I'm pulling and cleaning
so come with me, I'm
going to show you
the whole process, I'm
looking to make sure
this is 410
because these are
R22 locking valve
caps, somebody has
repurposed them
y'all can see
here we have
straight cool
so I'm gonna go ahead
and start valving
this off, forgive
me, I know this
is taking a while
but it saves a lot
of trouble, I'm gonna
go ahead and close
off this one side
right here, refrigerant flows
out this way, so when I close this
off, it can't escape, compressor is
still in there pumping and this side is pulling
so when you get all the refrigerant inside that
can you
close
that one off
too, okay
that is all
the way off
I don't want
to leave it
like that
open it a few turns and
then set my wrench back
the other way and pull
up the app look at our
pressure the pressure
right there is 185. i'm
watching that pressure
gradually get lower it's
as low
as it's
going to
get this
line
right
here
you'll
see that
really
low
teflon
o-ring
cannot
lose these two things now
this one i'm gonna this one i'm
gonna need to cut right about here
connects
so i
ought
to
be
able
to
just
remove
that
from
here
that
is
why
we
pull
it
and
clean
it
um
does
not
look
like
it's
had
much
maintenance
over
the
years
this
little
piece
right
here
that
i use to create a little bit of pressure it's called a bullseye
and this piece right here
comes with this
coil gun kit i'm
gonna add a little
water first that's
what i'm using the
fact that these are in bags and they're concentrated like
this makes it easier for me to use and store
in like this little pack out box i got all
my coil cleaning stuff right here
so i like just
storing those one gallon bottles of coil cleaner actually
is a little more difficult and in a
service
van
space
is a
premium
while
that's
sitting
and
soaking
for a
little
bit
back
on my
nozzle
get
ready
to
spray
that
off
i'm
still
getting
a
bunch
of
stuff
out
regretting
a
little
bit quoting them a pulling clean this is not perfect
but this section through here where the
fins are damaged i don't know
if um that came from a previous attempt
to clean this side the
fins aren't as damaged
but if they continue to have trouble with this that's going to be a
replacement
a
half
used
like
two
and
a
half
amp
amp
hour
battery
this
one
is
three
quarters
Okay
we have a couple of tasks we have to install
this piston goes in that direction put
your Teflon seal
in i got to find
the nut there's the
nut always start it
by hand if you cross
thread
one of
these
back
you're
going
to be
buying
a new
coil
from
the
pressure
test
as you
know
these
cores have been removed we're
getting ready to do a pressure
and bubble test with nitrogen
i just heard the contactor come back
on all right that alone added
a little bit of pressure
and this
sure that's
turned
off open
this up it's
on test
they're
open we're
going to
pressurize
what we're actually pressurizing is from the line set through
the evaporator coil this condenser is
sealed off i'm gonna let that pressure get up
to about 200, I'm over 100 psi right now and then
going to go bubble search, okay I have 215.8 psi
about 30 seconds on that, I have not dropped
anything, it's always possible to drop a little bit
of pressure through your hoses or your manifold
and this is not exactly a brand new setup, let's go
in and check for bubbles, I can already tell
you we're
probably
not going
to find
any but
let's go
and move
this away
from this
edge
and there's
a chance I
might cut
that just
to keep that
from causing
a problem
I'm actually
going to be trying something different, this
is Navac vacuum hose, half inch hose, half inch
connection
and quarter
inch connection
apparently they have
made the box adult
proof these here, I
don't know if those are extras
or yep, it's got an o-ring
in it, I have wanted a hose like this that
has a half inch end on it, it didn't make a lot
of sense to me to have a half inch hose, it's already
reduced to a quarter on one side
so I don't want to reduce
the other side, a split system I like to
hook my vacuum up
to the larger hose
which is our vapor
line, it's still good
fourth four bars
the different
part about
this vacuum line
is now I can hook
it up to the big
connection okay
I am pulling on this side, this side is valved off
that's where I'm going to put my micron gauge
I have a couple I use,
but I kind of like this one.
Okay, so now I just have to turn this on,
and it should start reading my vacuum.
It's
a good sign.
I'm below 800.
That is about five minutes
of run time.
Well, I was below 800.
There we go.
I think we're going to be fine.
I will tell you, when I bought that Navac hose,
there is a new core removal tool that they have
that has two other options where you can add a hose.
from here and here to increase your vacuum
and I almost bought it
was um 169 something like
that my my only problem or question
is that I've had trouble with valve core removal tools
and sometimes that little ball valve that turns off one side
or the other can be problematic or
part of the reason that they leak
and that one has three of them on it so um I don't know I might
try to look
for some reviews
before I buy
that one we
are about ready to
go let's go check on
our vacuum before it has had time
to time out we're already below 500 microns and that's real
nice by that's going to be good enough
for me pressure is still good valve that off so that
you don't ruin this we're going
to go ahead and put pressure to it
i always put pressure first
before i put the Schraders in there's a reason
for that when you're putting the Schraders in
using your valve core removal tool there's
a possibility of a tiny little bit of air getting
in there but if it's under pressure i'm sorry i'm thinking
of that David Bowie song Pressure
if it's under pressure
that won't happen that's
what i'm looking for
right there valve core
loosen the front of it a little
bit that's it that takes some
of the pressure off
the o-ring that
way when i'm pushing my valve core past it it doesn't damage
the o-ring as much when it's real
tight that o-ring is compressed
and it kind of sticks into the pathway and that's the number
one reason why people can't retrieve
their valve cores is because that o-ring stops it
that is one side
by the way i like
this hose i got
into a deep vacuum
rather quickly
kind of like
you do not want
to loosen the front
of these things up
too much because
there ain't a whole
lot of threads holding it
on now let's go ahead and open
this all the way it's going to take me
little while i'll be right back now with all
the trouble this thing had pumping down it's likely
that it may have been overcharged
and the refrigerant that's in it might be enough if we're
lucky i very much want to keep
those brass caps i try to make
sure that i do and these had um
little toppers in them i'm going to try to keep
those too this is a nice vacuum hose i kind of
want to take care
of it we're getting ready
to turn turn this thing
on this is a 410 system
and by the way that little bit of armor flex i used inside
was about all i had i know that this
needs some but in my quote uh
i didn't put it so i didn't go
get enough okay everything's
balled off
i think
contactors
pulled
in watching
my pressures
we do have a
piston which
means we
need to be more concerned
with superheat than sub cooling there we go now we're on the right
refrigerant i have 1.3 degrees sub cooling 35
degrees superheat those pressures aren't terrible
it's got to be better than what than what it
was but that does look to me to be a little bit low
on
refrigerant
so i'm going
to add a little
bit this is
not going
to need much
all right let's
open this up and this up a little bit it's really hard
for me to tell if you can see my
my numbers here i have a head pressure
of 284 sub cooling and right now is about 1.4 i just
valve that off super heat still around 30 degrees it's
not terribly hot in there obviously the air
conditioner has not been running for the last couple
of hours now once again this is a piston
so the number one thing we're
concerned about is that super heat
all right let's valve it off and
see where we are super heat looks like it's down
a little bit 26 degrees sub cooling is still at
one degree. My saturation temperature is at 42 degrees
and my pressures are 290 over 125.
That superheat to me still indicates that I might
be a little bit low, just a little bit. I'm gonna
let it sit for a second and I'll bring you back.
I have not changed anything and now my superheat
is 9.2 degrees, sub-cooling 1.2.
Pressures are about the same, 293 head pressure, 124 suction
and right now my superheat's
at 7.3 degrees 5.6 so obviously i'm
not charging anymore i'm at 5.4
5.5 i'm gonna leave
it right there
and part of the reason i know
that coil is damaged a little
bit that will affect this superheat maybe by a couple of degrees
and my blower was dirtier than
i thought actually actually the blower was not all
that dirty it was rusty so i'm probably going
to give them a quote to just replace the whole blower wheel
and that will help bring up that
super heat a little bit but for what we got
and how that coal looked that right there is pretty
good i'm going to leave it right there
so my intention right now
is to give them a quote for
replacing the blower wheel this armor flex
and honestly i think that coal is going i think the
coal is going to be okay in bad shape in my honest
opinion it's probably going to be abused again
within the next couple of years
and it's very likely that next time somebody has to
pull and clean it's going to turn into a new coil
at least if it's me that's what it'll be
I'm not sure
that that coil can
withstand much
more cleaning.
Around here, these
locking valve
caps are code. When you install a new system,
you're supposed to put locking valve caps on it,
but there's nothing that keeps me from taking those off
and putting these on. The main reason
for those valve caps and the code is to keep people
from stealing refrigerant. It just happens
to be very rare around here that that happens,
and sometimes those locking valve caps can be
problematic if somebody don't have the right key i
do hope y'all enjoyed that video that coil
really real bad and i i did kind of regret
a little bit that i didn't quote them a new coil
on that one but it all worked out i hope you enjoyed
the video if you did how about like and
subscribe y'all forgive me i just saw a carolina ran
on my vehicle check out the store in the
corner um there's some links in the description
for ACIQ to become an ACIQ dealer or if you might
want to buy one and um there's a link in there
for Jobber i truly enjoy Jobber it has made my
estimates and invoices look really professional they make it easy
to add pictures to a customer
like modeling serial numbers pictures of the equipment
and stuff the last software i used
which was QuickBooks they kind of made it difficult
for me to do that i had to take the
picture in the app and i don't have
to do that with Jobber makes it real easy i can just select
pictures off my phone add them
to it it's done it's there forever if i delete my pictures
it's part of the software there's a link
for that in the description too catch you on the next one