In this video I revisit a call I was just at a few days ago. I had replaced the condenser fan motor during a no cooling call. Then when they tried to turn on the heat nothing would work. I found the Honeywell thermostat causing the problem. It had lost its programming, which happens to be a frequent problem with them!
#hvacguy #hvac #airconditioning #skilledtrades #bluecollar @DiversiTechCorp @MilwaukeeTool
AI Generated·May contain errors
Hey guys. The other day I was out here
because it was a no cooling call and we replaced this
condenser fan motor. If I can find the video I'll try to leave a link.
Today we're out here for no
heat because nothing
is coming on.
Let's see what it is.
Stay tuned. Let's see.
Temporary hold. Heat on.
All right I might be in and out a little bit.
I'm gonna go outside and check it out. I think
first thing we should
do is check power we do have power
the next thing i would think is check for
low voltage i'm glad we have power
at least that tells me we may
not have a shorted compressor
i do have low voltage let's
go back and take another look
with our meter
at the thermostat
it is pretty cold in here yeah it's not that cold
but it's it's going to be let me see if
if we turn the fan on I think it
is but I got to verify all right
so I am getting 24 volts to the
thermostat the reason
I said that is because
your fan just came on heat
on make sure everything's
right and I can't see I know it's dark as hell
in here red yellow I'm getting ready to do here is
jump red to yellow and see
if that contactor pulls
in there it goes one
last thing to check
we did kill power the other day
when we changed the condenser fan motor so i'm going to check the
programming on that thermostat make sure we didn't lose
the programming i kind of think that's what
happened the thermostat may have lost its programming
because in cool this heat pump
will run in cool because it just needs to energize
y and green in a straight cool system
if a thermostat is set up for straight cool it will still run
this in cool but it will not run
it in heat so i think my thermostat has lost its programming
and there's another reason i think
that you see this batteries are dead it lost power it's
a good chance that's why that is what
happened and i have a um manual here
so let's check replace the batteries and check the
program let's see if i remember right we enter
this mode like this i'm gonna make
this non-programmable
as i had it on permanent hold 125 fahrenheit 271
conventional forced air heat that's what i was
talking about this is supposed
to be on two heat pump
and 205 air to air heat pump reversing valve
energizes b in heat right here
a Rheem unit has a blue wire energizes b
in heat almost everything
well most others energize o there
are some inverter systems now out that energize b also
probably all uh
this is minimum cool let
me make sure i think that's
minimum cool set point
430 minimum cool set point that's
what i'm setting i'm gonna leave
it right there heat okay now her
heat ought to come on when we put this on it lost
its programming yeah correct let me turn this up
what temperature you want it on i'm gonna put it
on like 72 okay it's gonna have a five minute time
delay i'm gonna wait for it
to come on and you should be good
sure i would like to sell them a
new thermostat that is not what they needed now
those honeywell thermostats if i have any gripe
about them it is that they do that they lose their
programming and sometimes they have a feature on
them where you can lock the thermostat where you have
to enter a code to get in it i have seen
where when they lose power
and come back on the customer will be locked out and they have to enter
a code and there never was a code entered
that happens a lot with those t-series thermostats
and i do not like it that's part of the reason
i've started using the pro 1 thermostats and so
far i haven't had that same problem i'm sure
in time i'll probably find some issues with those
but so far they have been dependable we all good guys
um that is a call i'm not going to charge
anything for labor warranty no parts
so um that happens sometimes i had somebody comment one time
in one of my videos that if they got a technician
that if they got a call back that they would lose
their job you know that's just that's just
not realistic even if you do a good job and everything
goes right something like that can happen
so um it happens thanks for watching i hope you enjoyed
the video if you did how about like
and subscribe check out the amazon store in the corner and i'll
catch you on the next one