If you’re interested in more business related videos I’m starting to publish them for members. In time I plan on have a full selection on how to manage and complete every step of opening and running a business! Join this channel https://www.youtube.com/channel/UCiz21FXLOV65NTgiUfJsxTg/join
In today's video, I visitor mobile home where nothing was working on the air conditioner. The tenant complains that it had been icing up. She had seen ice. But what I found I don't even know how it was icing on the air handler was not working and the condenser was not working plus there were multiple other problems come along with me. I'm gonna teach you something that everyone needs to know when they're trying to diagnose a motor that is not running. #hvacguy#hvac#airconditioning#airconditioner @Jobber @ACIQComfort 00:00 Introduction 01:30 Inspection 03:51 Diagnosing Motor 05:58 Relay 09:15 Relay Replacement 20:25 Registers 23:20 Condenser Fan Motor 26:45 Ending
Hey guys, in today's video I'm going to take you along on a call at a mobile home that had
multiple problems. Basically nothing was working.
You're going to say the system was in bad shape. I found problems that I didn't expect to find
and in this video I show you something real important when you're trying to diagnose a motor
that is not running. Basically I had two motors that were not running
and neither of the problem were the motor or the capacitor. Stay tuned.
What's it been doing? It freezes up. Is it freezing?
Okay, where's your thermostat? Is it down here?
Okay, I'm gonna leave this off right now
and turn the fan on and see if we can get the fan to come on. This is one where I changed
the filter because it had a 12 by 12 filter in it and it's like a three ton.
You see it does not have the right size filter. Can y'all see that?
But they do have it covered. We're going to take this off.
It's all ice. It was water. The water had been leaking down but I didn't see anything in there.
It freezes up on the outside when you try to turn it on. It freezes up outside.
How long has this been going on? It just recently had started when I had contact.
I think I tried to come by a couple days ago
and they didn't give me your number and I didn't have a way to get in touch with you.
Oh the spiderwebs. Yeah.
I can already tell this is one that has had troubles before.
And I think it was a problem with the blower because I see the blower control board over here.
Actually I should have taken that with me but it does help me see that I've been here before.
Okay remember I turned on the fan at the thermostat.
I do not hear that fan.
All right what I did in the past this had a fan that ECM motor for the fan controlled by this
board. We removed the board put in the relay and installed a PSC motor. So here's my low voltage.
Let's see if we can figure out what's going on. All right I think the first thing we need to do is
just verify a few things. She said it has been freezing up outside so let's just
we have 249 volts. Let me see if I can verify. I have 28.8 volts right there.
So we do have low voltage. What I'm looking for right here is whether or not we're getting a call
from the fan. I got my black lead here on common and this on green and I have I have 28.8 volts.
So the thermostat is calling for the fan to come on. It's hard to test like that. Okay this relay
is getting 28.8 volts. So honestly this motor should be turning. It does not feel hot. What I need to do
is ensure okay my white wire that the blower motor is getting voltage. That's what I need to
ensure. Okay we're using low speed and very likely this is my run side.
So it does not appear that the motor is getting voltage. What I do want to check
we're getting our voltage for the motor from up here. I'm gonna have to lay down there so I can
see in there. Hold on something I can do to make this a little bit easier. That little board can
come out. I just got to be careful. Oh there's another screw. We don't want anything throwing
sparks. Okay that might be far enough. So this is my my wire going to the blower motor.
That's going to be my run winding and it it does appear to be getting voltage. What I need to check
is this. There is a wire. Wait a minute is that no not that one this one. I'm going to check right
here. All right that does say that I'm getting 240 volts. All right the wire that I'm checking
is this one at the top of the relay. That top left and as you can see it goes to right here.
So I'm going to check from here. Okay that relay has failed. Go get us a new relay. Maybe
something a little more dependable. I'm thinking about a 9340. Change the relay and check again.
Looking for something error handler 11 and 13. That's this one. It can't be right 25.
Maybe. Let's check. I see you got a vent taped off in here.
So you need a vent for that? We need vents for all of them. All of them? Where'd they go?
Wait a minute. We had the plastic ones. Wait wait wait. But they done broke up and they
All of these are covered?
May I look at the others?
Are all of them taped off?
Where'd they go? Were they not here when you moved in? The vents was plastic when we moved
here. Uh-huh. You know how plastic vents look right? Uh-huh. If you step on them they might
break. Yes they're easy to break. So we've asked them so many times. They supposed to
bend all those new vents. We've been asking and asking. Never did bring them to us. Okay.
I can get this going but I got to take that tape off. You can take it off. It's no problem.
Because it ain't gonna work with that tape on it. Yeah you can take it off. Okay. And I'll tell you
what. I'll measure your vents. Okay. And I'll see if I can go get you something. Okay. Thank you.
Thank you. And then I have to ask for permission but I'm pretty sure to. Thank you.
All right that was nothing right there. So it was not that one. This is one of the biggest
ones in here. It only has number 10. Let's try that one. That's a 30. I got no power.
That's what I was looking for. It is a 9340 relay. That'll work. It's another 9340.
And another one. I'm actually looking for what I call a peanut relay. I do not see one in here.
And if it's not in there I might not have it. But these are more dependable. Let's just go
ahead and use this. Just making sure that I don't have power. Okay. All right. We were using blue.
I think because of horsepower reading or something. Okay. On these relays. Once again this is a 9340.
Now first I should probably tell you on these. This is my low voltage. This is normally where
with the five spades like this. These are normally open and these are normally closed.
So when this activates with 24 volts it closes this one to this one and brings on the blower.
This one is for the heat strips. If you follow that all the way back when it brings on the heat
it activates that one and brings on the heat strips without having to need 24 volts right here.
So this is normally closed. This one's normally open. On these 9340 relays I'm going to try to
hold it upright. Low voltage goes here or here. And this is what I'm going to call my common for
my blower motor. We're using one speed but this is capable of two. This is my normally closed
and this is my normally open. You can see it on the diagram on top of the relay right there.
And this is another set of contacts that do the exact same thing. Now sometimes people will put
their high speed right here with a normally open and a low speed right here with a normally closed.
But we're just going to use one speed. So we're going to have our normally closed here
and our normally open. It's easy to do as long as you know which one is your common wire. And in
this case it's black. Okay I'm going to go ahead and take these off. That is my low voltage. This
thicker wire here that's going to be my normally open. I'm going to go ahead and hook that up.
Make sure we have a good connection there. And this is our normally closed.
And we had our blue speed hooked up. If you look it goes right here. Right there. Of course we're
going to hook up our low voltage. Let's see if I can use that hole right there. Yep. Forgive me
if you can't see. Can't see another. I don't see another way to. We still need our low voltage.
This is our call from the thermostat. I know it looks like a jumble of wires.
But in time with practice it becomes much less confusing.
All right we're about to put power to it. And because the fan is turned on
it should come on. I'll just go do that. I'll leave the camera running.
Blow your hat off. All right that is 10 inches. It's 4 by 10. I think they're all
going to be the same but I'm fixing to go check. Let's see if we can get this to fit in there.
Much better.
They even put two up there. We don't know what's going on.
Can get that. That's been stepped on. I'll do this one a little different.
Y'all hold on. Stepped on this. Mm-hmm. And felt them and everything. Man those plastic ones.
Yeah I don't know. They should not be on the floor in my opinion. Yes.
They're made for the floor or they say they are anyway.
Much better isn't it? Yeah.
Okay we got a problem. It is cooling. Condenser fan motor is not running. I was not expecting
there to be a problem with the condenser. Just goes to show you you got to check. Okay contact
is pulled in which means we are getting a call. Let me see. My comment from my condenser fan motor
should come down here to a relay. Right there. A relay on the board. This is it right here.
So I need to make sure I'm getting voltage from here to this yellow. I can't really tell if it's
too hot because we just turned it on. It's in the sun. Because this board can fail. I gotta say that
capacitor lugs. But there's something dead on top of it. Okay fan is not turning. So what I'm
checking this is my run winding and this is my common. I do not have voltage. One second I'm
about to lose it. Okay to better explain this defrost board. When it goes through defrost
when it's when it's running in heat it kills power to the condenser fan motor by cutting power
from this line which is one of these up here to this line which goes to the condenser fan motor.
So what I'm going to do right now to make sure they have cooling and make sure that I'm right
about the voltage. Uh-oh that board's just barely on there. I'm going to put this wire
up here on top. We're going to put power back to it and see what happens. No? Okay.
Okay we know the fan works. Our problem is this board. I think that while I'm out here
because of the way that capacitor looks up there. I'm gonna go ahead and check it.
But um that's one of your rule of thumbs on any motor. Before you condemn the motor
you gotta make sure it's getting voltage. Sometimes you can tell it's getting voltage
because it's hot. Neither one of these motors that we worked on today were getting voltage.
Make sure it's getting voltage before you condemn a motor. Okay as you see right there that's Riley.
He just picked a pear off the tree. I did quote them a price on the defrost control board on that
one. I think we left it safer better and more dependable. I hope you enjoyed the video. If
did how about like and subscribe. Check out the store in the corner. Look at the stuff in the
description. I've been using Jabra lately. I really like it. And if you want to be an ACIQ dealer
there's a link down there for you. I'll catch you on the next one.