A Particle is a Particle

CDC
258 followers
Dec 31, 2025
This video explains how NIOSH-approved respirators protect workers from a wide range of airborne hazards. Learn what aerosols are, why “a particle is a particle,” and how respirator filters capture particles through mechanical and electrostatic methods. The video also describes NIOSH respirator certification, including N95 filtering facepiece respirators, and explains why certification testing uses worst-case conditions to ensure high levels of protection across healthcare, construction, laboratory, and other work settings.
This video can also be viewed at
https://www.cdc.gov/niosh/video/A_Particle_is_a_Particle_LoRes.mp4
As a key component of its mission, NIOSH is dedicated to advancing the state of knowledge
and application of personal protective technologies, including air purifying respirators,
which will be referred to as respirators in this video. Various types of these respirators,
such as filtering facepiece respirators and elastomeric half-mask respirators,
are used to reduce personal exposure to potentially harmful aerosols.
The term aerosol includes both solid and liquid airborne particles of varying size,
shape, and density that are often invisible to the naked eye.
Whether it's a virus or bacteria, concrete dust or engineered nanoparticle,
it's important to understand that the type of particle does not affect its ability to be filtered.
A particle is a particle. This means that respirators can be used to protect workers
from a wide variety of aerosols. For example, respirators can be used to protect a health care
worker who might be exposed to tuberculosis or other airborne pathogens. To protect a
construction worker from airborne particles generated by sawn concrete.
Or to protect a laboratory technician who handles engineered nanoparticles.
All respirators selected by Respiratory Protection Program administrators
must pass NIOSH's stringent certification process. NIOSH certifies respirators based
on how efficiently they filter airborne particles and how resistant they are to oil.
For example, the most commonly used respirator is an N95 filtering facepiece respirator,
which filters at least 95% of airborne particles and is not resistant to oil.
To ensure optimum protection, respirator users should only wear respirators selected by their
organization's Respiratory Protection Program administrators as being the most appropriate
for their working conditions. As the user breathes and causes air to pass through the filter,
the dense network of fibers in a respirator capture particles through a combination of
three mechanical methods, impaction, interception, and diffusion. Some respirators contain
charged fibers that use a fourth method, electrostatic attraction, to attract nearby
particles. Impaction occurs when a particle's inertia prevents it from adjusting as the airflow
carrying it into a respirator changes direction when it nears a filter fiber. In this capture
method, the particle hits a fiber head-on and becomes stuck. Other particles can become attached
when the airstream carries them within one particle radius of a fiber. This is referred
to as interception. Diffusion occurs when smaller particles follow a random motion as they are
bombarded by air molecules. Those that come into contact with a worker's respirator are captured
by its network of fibers. With all of these capture methods, once a particle comes in contact
with a filter fiber, it is removed from the airstream and strongly held to the fiber by
molecular attractive forces. If the respirator contains electrostatically charged fibers,
that charge will cause more particles to be captured. The method of capture is largely
influenced by the characteristics of a particle, such as aerodynamic diameter, density, and charge.
However, the filter's ability to capture a particle is not affected by whether that particle is a virus,
concrete dust, or engineered nanoparticle. Remember, a particle is a particle. NIOSH tests
respirator filters for their ability to capture particles that might be found in occupational
situations. The conditions, such as particle challenge and the flow rate for certification
testing of air purifying respirators, are believed to represent near worst-case conditions for all
types of workplaces, meaning the test conditions produce maximum filter penetration. This ensures
that filters in NIOSH-approved respirators will collect hazardous workplace aerosols with very
high efficiency. Based on the considerable collective knowledge of the scientific community
regarding aerosol filtration, it is not necessary to test a respirator filter with a biological
aerosol because certification testing applies a worst-case set of test conditions. Again,
because a particle is a particle, when properly selected and used, NIOSH-approved
respirators should provide the expected levels of protection against all types of workplace aerosols.