www.koffeeone.com.au
boiler tanks access to access the boiler
tank assembly the engineer needs to
remove the back panel take out the two
back screws on the top panel with a
Philip
screwdriver the talento has two
boilers one for coffee and the other for
steam the coffee boiler tank has a
capacity of 2 L the steam tank has a
capacity of 3 l both tanks are in
stainless steel and insulated and each
has a 2,600 WT heating
element the tools required here are 10
12 17 and 37 mm wrenches a Philips
screwdriver pliers Clippers and
clamps boiler tank and fuse
components the coffee boiler tank is
comprised of a temperature probe 16 Bar
expansion valve hot water solenoid valve
connection fitting
Add Water solenoid valve connection
fitting coffee solenoid valve connection
fitting safety thermostat 98° Centigrade
CSA version for the North American
Market
only the steam boiler is comprised of
safety thermostat 150° Centigrade CSA
version for the North American Market
only level probe temperature probe six
bar expansion valve steam solenoid valve
connection fitting cap Chino maker valve
connection
fitting in the bottom part of the coffee
boiler tank is a 2,600 W heating
element fuse
167° drain
plug and water inlet
connection the steam boiler tank
contains a 2,600 WT heating element fuse
[Music]
184° drain plug
and water inlet
connection to replace the fuse it's
necessary to switch off and unplug the
talento next disconnect the fuse
connections and slide out the fuse from
the
bottom this operation takes place in the
bottom part of the boiler
tank draining the boiler the boiler tank
needs to be emptied in order to change
the heating element or before removing
the boiler ass mbly to empty the coffee
boiler tank the engineer needs to open
the drain plug with the machine Switched
Off and once the boiler tanks are cool
using a 17 mm
wrench insert a drain pipe and then open
a fitting in the top part of the
boiler to allow air to enter and
therefore water to come
out wait for the tank to empty
completely and then tighten the fitting
that was previously opened using a 12 mm
wrench before closing the plug again
this procedure is the same for the steam
boiler
tank heating element the boiler tank
needs to be removed in order to replace
the heating element once the boilers
have been emptied the engineer needs to
unhook the Teflon pipe from the
fittings to the steam
solenoid hot water
solenoid Add Water Sol oid and safety
thermostat CSA version only next remove
the clamp from the expansion
valve and slide out the silicone
pipe the engineer will unhook the power
cord for the two heating elements and
the Teflon water inlet pipes in the
bottom part of the
boiler open the left side panel
loosening the two screws on the top
panel with a Philips
screwdriver remove the coffee boiler
tank temperature probes yellow and the
steam tank temperature probe red and
free the
wires take off the clamps on the Center
Bar of the bar
panel and free the wires
then using a 10 mm wrench take out the
four screws securing the two boiler tank
support bars to the
frame securing the boiler in a vise and
using a 37 mm wrench it's possible to
loosen and unscrew the heating element
during the refitting stages make sure
that the seal is completely inside the
special
seating tighten the screw with a 37 mm
wrench