Can a 1904 steam AC generator power a modern appliance¿ .

Terrific Physics
41 followers
4 Video Views·Nov 19, 2024
Hi, Saundro here. Isn't electricity just oh so convenient? It makes me wonder what might be at
the other side of that line. Might it be a 120-year-old steam engine? Of course, in reality,
following the power line and finding a piston-driven steam engine on the other end is not how Switzerland's
modern power grid works. It is fed by many power sources, 52.8% of the power coming from
hydroelectric as in 2023. But my actual question was whether it could be. And there the answer is
yes. How can I tell? Because I saw it with my own eyes and so can you.
This is the second of a pair of videos documenting the historical backup generator from the Gossbach
Schlieren. This machine is a fully functional steam generator, built in 1904 and now kept in
perfect working condition by the Association of Volunteers TGVZU. While my previous video
focused on the steam engine, this video covers the enormous generator that is driven by it.
Are you ready to discover the brilliant electrical engineering in a time long before the first
transistor was invented? Let's go full steam ahead! While I shall leave most of the history of this
place to the previous video, let me quickly recap that this facility used to be part of a large
factory producing town gas. Since the factory needed to operate 24-7 and was a crucial service
to Zurich, a power outage would cause a lot of damage. Therefore, three of these steam engine
generators were stationed here, in the middle of the factory, producing electrical power from coal,
an abundant resource in a coal gas plant. They had the difficult job to keep the choice coming,
no matter what. But generating electricity is simple, right? In school, they taught us that
you can simply wrap an insulated copper wire around a core to make a coil. Then just make a
magnet rotate inside that coil and it will shove the electrons in the copper wire back and forth.
Connect the wire's ends to a load and you end up with alternative current, or AC. When measuring
the voltage between the two wires, we observe that it oscillates back and forth, forming a
sine wave corresponding to the rotation of the magnet. We thus have effectively created a
simplistic AC generator. Time to name our parts. Since the magnet is rotating, we will call that
part of the generator the rotor and the surrounding coil, which is stationary, is thus called the
stator. But we're not done here. Switzerland's power grid has, like many others, three-phase
current. This means that you simply take three times what we have already, with the sine wave
shifted by a third for each. To adapt our generator, we install three coils instead of one.
Now, since the coils are all powered by the same rotor and their electric signal is thus coupled,
we can tie one of their ends together, allowing our generator to have three plus one output wires
instead of six. The common end is called the neutral and the three other ends are called the
three phases, L1, L2 and L3. If we were to connect a multimeter between any two of those phases,
the display would read 400V. If, however, we connect it between the neutral wire and any of
the phases, we get 230V, which is what is delivered to the Swiss homes, meaning that one of these
holes is connected to neutral and the other to one of the three phases. With that in mind, let's
return to our steam-driven generator. We will tackle the stator first, which, just like in the
example, houses the three coils, each providing a single phase. The coils are made out of copper
and are electrically insulated from each other. Unfortunately, they're all painted black,
so let's bring in some color, shall we? Painting the first phase in red, we see that it follows
the stator in a zigzag pattern, surrounding it once completely. However, it doesn't stop there
but comes back for yet another round. The two other phases are doing just the same but slightly
offset each, giving the characteristical triple sine wave of three-phase current that we seek.
The beginning and the end of each phase are located down here below. Four wires connect to
them, one being the shared neutral and the other three being the three conductors. If you were to
connect a modern lamp between any two of the three phases, it will work perfectly. If you were
listening carefully before, you will notice that this isn't quite how Switzerland's actual power
grid works. There, we had 230V between a phase and a neutral. Here we have 220V between two phases.
Still, the frequency matches and the voltage is just 10V apart, so most modern appliances
would work when connected between two of these phases. Moving on to the rotor. In our example,
we had used a simple permanent magnet, but in addition to lacking the ability to be regulated,
those were too weak at the time and would still be way too expensive to build into a generator of
this size. Luckily, we can use another electrical trick from school. Wrap a wire around a core,
run DC power through it, and you have an electromagnet. For now, let's ignore where
that DC power comes from and instead just observe the coils. As you can tell from the interconnections
between them, each coil is wired in reverse to the other, causing them to be of opposite polarity
each. So unlike our little permanent magnet, this rotor here has a multitude of north and south
poles when powered with DC. When it is at speed, it rotates such that at any given point in the
stator, 100 poles pass by every second. Since they're alternating between north and south pole,
this equals 50 Hz, which is the frequency of Switzerland's power grid. A big advantage of the
rotor's poles consisting of electromagnets instead of permanent ones is that their power can be
regulated. When running more DC power through the poles, their magnetic field becomes stronger and
the AC generator thus produces a higher voltage. This way, the much smaller DC current can be used
to control the much larger AC output of the generator. But where is that DC power coming from?
You have probably guessed it, it's produced by a second, smaller generator located on the same
shaft. In this generator, the role of the stator and the rotor are flipped. The stator contains the
magnets and the rotor has the coil. As the coil rotates in the magnetic field, an AC current is
induced in it. Yes, that's right, AC, but we need DC here. To achieve this, we have to flip the
rotor's polarity whenever the current changes direction. This is done by this commutator,
with a brush picking up the electricity on top and another on the bottom. Since the commutator
rotates with the shaft but the brushes don't, the physical rotation cancels out the alternating of
current and thus the brushes finally pick up DC. For a cool animation about this, check out the
video of Horvoye Engineering, Schorvoye Engineering, Chorvoye Engineering, sorry, anyway, the link is
here. Unlike the model in that video, our rotor here has many coils and thus the commutator has
many more poles than just two of them. This makes the generator produce a stronger and smoother
output, but the principle is the same as in the model. With the DC generator's rotor covered,
let's look at its stator. And there things get interesting, because it is yet another electromagnet.
And in this case, the generator feeds on itself, taking a fraction of its own DC output to
magnetize the stator's poles, inducing a current in the rotor producing more DC. Within this loop
is a variable resistor that the operator controls to regulate the current flowing into the DC
generator's poles. But now we have a bootstrapping problem. If the generator is off, how do we feed
it DC to make it produce more DC to make the big generator produce AC? Turns out, the DC generator's
poles are not entirely electromagnetic. Their iron is pre-magnetized, making them also be permanent
magnets. Those are very weak, but the induced current is enough to produce a small amount of DC
which then fed to the poles for self-amplification. To bring everything together, this is how this
crazy setup is started up. First, water is heated up to create pressured steam. Then, the steam
engine is ramped up to its full speed. This causes both rotors to spin and thus a small current is
induced in the DC generator's rotor by the weak magnetic field of its stator's poles. This DC
current is then directed to those very same poles, amplifying the magnetic field and producing a
larger DC current in the rotor. This current is then sent through this slip ring to the AC
generator's rotor, waking it up so to speak and generating three-phase AC current that can then
be sent to the factory's power grid. The operator can adjust the before-mentioned variable resistor
to change the DC generator's own DC input, regulating the AC generator's DC input, regulating
the final output. Due to all of these extra steps, the AC generator's electric field takes a few
seconds to build up. Once it does, it produces an intriguing howling sound. Listen carefully as
Walters turns on the field, then takes it back down.
While this system used to power huge electric machines, nowadays it is a witness of the past
in this extraordinary little museum. For demonstration purposes, TGVZU has hooked
the machine up to six halogen lamps that illuminate the whole assembly with its own
electricity. However, that is way too little load for the powerful generator and thus most of the
load comes from an additional resistor that the team had installed to keep their electric
mini-grid stable. And now you know the whole story, all the way from the heat to the watts.
I hope this wasn't too much taking in, let me know your thoughts in the comments.
Again, a huge thank you to the TGVZU and in particular to Walters, who has been very patient
with me. And of course, thank you very much to my Patreons, who support my independent work.
If you want to become one of them, check out the link in the description.
And with that, well, thanks for watching and have a very nice day, bye bye!