RV furnace won’t IGNITE, TURN ON, OR STAY LIT? Repair and Troubleshooting advice!

Enjoy RV and Van trips
18 followers
6 Video Views·Nov 9, 2024
Do you have an RV furnace that is blowing cold air, won't ignite, won't turn on, or won't stay lit? Trust us, we've been there. This is a step-by-step troubleshooting video to help you solve your maintenance issues and repair your RV furnace!
0:00 Chapters
1:04 Stage 1: Is the blower fan running?
1:50 Stage 2: Does the furnace attempt to light?
3:22 Stage 3: Does the furnace stay lit?
6:18 Stage 4: Does the furnace stay lit all the time?
Home A Roam, All Rights Reserved
This channel is for entertainment purposes only. We are not experts, and are not making recommendations. We share what works for us, so please do your research to determine what works best for you.
Do you have a tricky RV furnace problem that you just can't figure out?
Maybe the blower is coming on but it's not lighting or maybe it's lighting but it's not staying lit.
It was literally just going. We've been struggling with furnace issues since our trip to Ontario
and the furnace quit and every time we fixed it or we thought we'd fixed it the problem kept
coming back. Our heat cut out in the middle of the night so I've spent hours and hours troubleshooting
and diagnosing and putting together a nice step-by-step guide for you to save you time
and frustration. And this video comes with a free downloadable pdf quick reference guide so stay tuned.
There are just so many things that have to go right to get an RV furnace to fire up and give
you heat. I've broken down the startup sequence into four stages. Stage one. Is the blower fan running?
This is the very first thing you need to check. If it's not, stop right there. If your furnace is not
blowing air that means it's not getting 12 volt power. So first check that the fuse is properly
inserted and hasn't blown. Second, make sure you have sufficient battery power. Right, your battery
power should be reading at least 12 volts and preferably higher. You can check this using your
battery meter or get a more accurate reading using an ammeter. Try the furnace again with a fully
charged battery or hooked up to shore power. If your blower motor is now running, congratulations!
You are well on your way to a working RV furnace. The next thing to check, stage two. Does it attempt
to light? You can check this by turning on the thermostat then standing outside where the exhaust
port is. 10 to 15 seconds after the blower motor starts you should hear a click and smell some gas.
If you do then that means it's at least trying to light. So the blower comes on
then you can hear a click. If there's no click that means it's not attempting to light due to
the system's safety features. The key suspect here would be the sail switch. The next thing
I'm going to look at today is something called the sail switch. Now this is a switch that senses
air flow and decides whether it's going to actually tell the furnace to ignite or not.
And these switches can apparently get gummed up with just dust, pet hair, all sorts of stuff. You'll
need to take it out, inspect and clean it and then reinstall it. It could also be a bad high limit
switch. This is a less common problem but if you're sure your sail switch is good this is the next
piece to try and swap out. And if it's not one of those two switches then it could be your electrode.
That's the bit that creates the spark. It needs to be clean, free of corrosion and have about a 1
eighth inch gap between the two metal pieces. If your furnace is trying to light, congratulations
you are that much closer. You're now at stage three. Does it stay lit? Our furnace was lighting
up, blowing warm air out the exhaust and then poof it just stopped. All right we're gonna see if it lights.
Oh it lit.
Will it stay lit? No it will not. If your furnace won't stay lit the first thing to check is your
gas pressure. I thought to myself, you know general troubleshooting for the furnace, I never actually
checked the propane. Turn on all the burners on your stove. Do they have a strong blue flame? If
the flame is weak or yellow it could mean your gas pressure is too low. Try again with a completely
full propane tank. If you still have signs of low gas pressure it might be a faulty regulator which
is thankfully fairly inexpensive and easy to replace yourself. If your gas pressure looks good
things get more complicated. It could be the flame sensor or electrode. This might be the time to call
a qualified technician. Or if you're comfortable working with LP gas systems you can take out and
inspect your electrode and burner. I mentioned earlier how your electrode needs to be clean
and have the correct spacing between elements. Your burner also needs to be clean and intact
to produce a sufficient flame. Finally it could again be your control board. This seemed to be the
main cause of our problems. Our furnace was lighting but going out after a few seconds.
After doing some research on some forums we found that water intrusion on this type of
furnace is actually a big problem. So I took off the circuit board and underneath is a massive
pool of water. So it was sitting with all these nice little circuits in the water and actually
running. It just wouldn't stay lit. So I am shocked that it just didn't completely short out.
About a week or two ago I called up Dometic and I explained to them the whole situation
with our circuit board getting drenched in water and sitting in a puddle. And they said that yeah
that's a known issue and we're going to send you up a kit to mount it so it's not sitting in water.
How about that eh? That's just a little plastic piece. Well as it turns out they actually sent
me a whole new control board. So that's like a $150 control board that they sent me at no cost.
So huge shout out to Dometic. Great job there. So it's likely that the flame sensor was returning
a good signal but the old control board wasn't picking it up. So it would shut the gas valve off
after a few seconds. Replacing the control board solved it. So at one point we were having
intermittent problems. Most of the time the furnace would light and stay lit but then every so often
it would just conk out. The occasional problem got more and more frequent until it wouldn't stay
lit at all. So if you're having periodic troubles take action quickly. Intermittent problems are the
hardest to diagnose. I've covered the main suspects already and I would focus your efforts mainly on
the gas pressure and the control board. At the time of recording this a new regulator cost about $30
to $40 US and a new control board will run you just over $100 US. If you're comfortable doing
your own repairs it may be worth replacing these two components first to see if that solves it.
And if that doesn't work or you're simply not comfortable DIYing it
then it might be time to call up your friendly local RV repair technician. We hope these tips
help you with your RV furnace troubleshooting. As I mentioned earlier we put together a downloadable
PDF document that summarizes everything we've talked about just now. Check the link in the
description below. And if you found this video useful we'd really appreciate if you could give
us a like and subscribe and hit the notification bell of course. It really helps us out. Thank you.
And if you don't mind take a moment to comment about your RV furnace troubles and
successes. And in the meantime keep on living the life you've imagined.
You can't figure out? Maybe the furnace...
I made a quick reference PDF that you can download.
Maybe the blower is coming on? No.