三洋洗衣機顯示EA1,教你檢查方法,十幾塊錢換個件就能修好 #我愛電器維修
我爱电器维修
89粉絲
我們的視頻是為了為觀眾提供有價值的內容,絕對沒有任何違規行為。 我們的視頻是為了為觀眾提供有價值的內容,絕對沒有任何違規行為。 非專業人員請勿直接操作!
哈嘍,大家好
分享通俗易懂的維修視頻
讓維修從此變得很簡單
專業(手機,電腦,監控,家電)維修
喜歡我就訂閱我哦
https://www.youtube.com/channel/UCma9sHXyCIBoYmC0PzDmLNw?sub_confirmation=1
三洋洗衣機顯示EA1,教你檢查方法,十幾塊錢換個件就能修好 #我愛電器維修
#我愛電器維修#家電維修 #電器維修
hello friends
Today we repair a Sanyo washing machine
Its problem is after washing for a while
Displayed error code e A1
Now let's take it apart and examine it
After we take the washing machine apart now
let's take a look
first step
The first thing to check is this water level sensor
The water level sensor is here
buckle this down first
let's take a look
After the water level sensor it has a problem
it will show error code EA1
In this case we have to remove this
come check it out
See if it's the problem
When we disassemble, we can see that there are three lines on it.
Let's take a photo with our phone first
waiting for installation
and put it in this order
Don't get the order of these three lines wrong
Then there is a tube on this
Let's pull this pipe out of the way
Let's take a look after we take it apart
The water level sensor
We can simply judge
See if he is good or bad
we can
Put your mouth on this tube first
give him some pressure
Listen to whether there is a sound of suction inside him.
If there is a clicking sound
Well, it can be roughly judged that this is not bad.
This is just an approximate judgment and can't say 100%.
If you want to be more precise
We can use a multimeter to see
The three lines above
This is a mechanical water level sensor
This pin corner is a common pin
Then the other two wiring is a low water
The other one is high water
We can blow him a pressure with our mouths
Measure the pressure with a multimeter
Uh, a test pen to connect this
Then another test lead is connected to this pin
If you can hear a click inside
Then he can turn on to prove the low water level
he is normal
And then we'll go up and blow him some pressure
Measure this foot again
See if they can get along
if he can also conduct
After turn on
All three pins are fully turned on.
If it can be turned on
It proves that the water level sensor is a good one
If only these two are connected during the test
Then this doesn't work
he still has problems
Now after I check the water level sensor
It is normal to find that the water level is low
High water level, if it is not directly connected, it has a resistance value
So his question
It's the water level sensor.
The measurements aren't 100% accurate either.
we better be
Get a new one and test it
this is the best way
and this one is new i have put it on
This is the broken one that was taken apart
Now let's test
If it's okay, it's his problem
In the case of EA1
The most bad one is actually this kind of water level sensor
After replacing it, we are testing it.
no problem
Look, the countdown is now 8 minutes left
Okay, thank you for watching the video today
see you next time