Introduction Methodsofmeasuringtemperature Thermocouples ThermocoupleMaterials Thermistors Pyrometers To access the translated content: 1. The translated content of this course is available in regional languages. For details please visit https://nptel.ac.in/translation The video course content can be accessed in the form of regional language text transcripts, books which can be accessed under downloads of each course, subtitles in the video and Video Text Track below the video. Your feedback is highly appreciated. Kindly fill this form https://forms.gle/XFZhSnHsCLML2LXA6 2. Regional language subtitles available for this course To watch the subtitles in regional languages: 1. Click on the lecture under Course Details. 2. Play the video. 3. Now click on the Settings icon and a list of features will display 4. From that select the option Subtitles/CC. 5. Now select the Language from the available languages to read the subtitle in the regional language.
Welcome, to the next lecture on Temperature Measurement.
In manufacturing, there are three process parameters which are very important.
One is pressure, another one is temperature and the last one is time.
If I can monitor them, that means to say measure them and then understand them, then I can
dictate the process through which the part is made.
So in these three parameters, temperature is also one parameter which is very very important.
If I can know how to measure the temperature and monitor it, then I can understand more
about the process.
Let me give you a very simple example.
Whenever there is a fever, we have a temperature rise.
That means to say our body temperature is measured from may be 98 degree Fahrenheit
to 108 degree Fahrenheit.
I am just approximating it.
So this is the temperature when the body moves towards a higher temperature.
There is also something called as fever at lower temperature.
This in a very crude sense, people call it as cold fever.
So here the body temperature falls below 90 degree Fahrenheit.
The temperature which is on this side 98 to 108 measurement is very much available everywhere.
Here you can have contact type, you can have non-contact type, okay.
When you talk about contact type measurement, you try to keep a thermometer, then you can
also have a paint, thermal paint which is there which we keep it on the forehead and
measure.
But we currently do not have a technology to measure a temperature anything less than
98 to 90 and measure the body temperature.
And once the body temperature goes below a certain limit, then it is very deadly and
the brain starts failing.
See we know this side, but we do not know this side and we do not have devices which
is normally used in the hospital at this side.
So you see temperature still it is a huge challenge to measure, okay.
And the next operation what I would take is in machining.
In machining what happens, we always try to measure the temperature which is getting induced
while the process is happening.
But here what happens is when you try to take a surface, there is a thermal conductivity
done on the surface.
So the temperature what we measure at a point and a slightly far away, there is a difference.
And then we try to measure it by contact type and non-contact type.
But still however best we say we are not exactly able to measure the temperature at the contact
point.
There is lot of research which goes on and lot of advancements which is happening.
Still there is a huge challenge in temperature measurement.
So our next topic of discussion is going to be temperature measurement.
So our content we will have an introduction, followed by it different methods of measuring
temperature, thermocouple which is commonly used in manufacturing platforms or manufacturing
industries.
So then we have thermocouple material, we will understand little bit about thermocouple.
Then we will talk about thermistors and finally about pyrometers.
The first thermometer was developed by Galileo in 17th century.
In 1724, Fahrenheit, a German physicist contributed significantly to the development of a thermometer.
That is why we still call it as Fahrenheit.
The Swedish physicist Celsius in 1742 developed a mercury in glass thermometer very long back.
And even today this is a well proven technology.
Look at it.
Its inception is 1742.
Even today we follow this mercury based glass thermometer for measuring temperature.
William Thomas, the first boron Kelvin, popularly known as Lord Kelvin, a British physicist
introduced a new concept known as Kelvin scale.
So Kelvin scale when the temperature goes below zero, all these things come into existence.
So the stars who contributed towards thermometer are Fahrenheit, Celsius and Kelvin.
They are all remembered today for temperature measurement.
The scales used to measure temperatures can be divided into relative scale, that means
to say Fahrenheit and Celsius and absolute scale which is Rankine and Kelvin.
So there are they are divided the measurement of temperature can be divided into two types
relative scale and absolute scale Fahrenheit and Celsius, then Rankine and Kelvin.
So here is the relationship between each other ok.
Suppose you know one with this relationship, you can cross correlate with the other Fahrenheit
is 1.8 times C plus 32, Celsius is F minus 32 divided by 1.8, Rankine is F plus 460.
Suppose if I know Fahrenheit, I can now convert it into Rankine, then Kelvin is C plus 272.
So if I know Celsius, I can try to figure out Fahrenheit, I from Fahrenheit I can cross
correlate with that of Rankine.
So you can see this relationship is very important which is used to change the scales from one
type to the other type.
So different methods of measuring temperature, contact type sensors are classified as the
following thermocouple, liquid in thermometer, resistance temperature detector RTD, pressure
thermometers, thermistors and bimetallic strip thermometers, bimetallic by two different
materials put in a strip form to measure temperature.
In case of non-contact, contact non-contact, in case of non-contact the radial power of
infrared or the optical radiation received by the object or the system is measured.
So non-contact type sensors are radiation pyrometer, optical pyrometer and fiber optic
thermometer.
When you go to airport and just before going for the immigration check, today you can see
lot of infrared cameras installed which they used to try to scan the temperature in a non-contact
manner and find out if the person is having any temperature and if there is any peculiar
behavior in his body temperature then they quarantine.
So that works on radiation type measurements.
Thermocouples, a thermocouple is an electrical device consisting of two dissimilar electrical
contacts forming electrical junctions at different temperatures.
A thermocouple produces a temperature dependent voltage.
So as so you can say the voltage and temperature as the temperature increases the voltage increases
may be just for simplicity I make it into linear ok.
As the thermocouple produces a temperature dependent voltage as a result of thermoelectric
effect and this voltage can be interpreted to measuring temperature ok.
So you measure temperature, then measure temperature converted into voltage, then this voltage
is calibrated already and then what you get to see is a temperature.
So this is a thermocouple which is used and these are the junction points.
The law of thermocouples, there are two laws of thermocouple.
One is called as law of homogeneous circuits, the other one is called as law of intermediate
metals.
What is law of thermocouple?
Law of thermocouple circuit, this law states that a thermoelectric current cannot be sustained
in a circuit of a single homogeneous material regardless the variation in its cross section
and by the application of heat alone.
So I repeat the law states that the thermoelectric current cannot be sustained in a circuit of
a single homogeneous material ok regardless of the variation in the cross section that
means to say thicker thinner and by the application of heat alone.
So you have a temperature 1 here, you have a temperature 2 or temperature 1 here, 2 here
and you have an emf which is created, 3 and 4 are the other sources.
So the law of intermediate metal, if an intermediate metal is inserted into a thermocouple circuit
at any point, the net emf will not be affected provided the two junctions introduced by the
third metal are at identical temperature.
So if you have metal A, metal B and metal C, so you have a junction.
So they say that the net emf will not be affected provided the two junctions introduced by the
third metal by the third metal are at identical temperature.
So two laws, one is law of homogeneous circuit and the other one is called as law of intermediate
metals.
So these two are the basic laws depending upon these laws you can try to develop thermocouples.
So what are the different types of thermocouple materials which are available today?
The base metal type are T copper 40%, T, J, E and K.
When we try to measure temperature in the manufacturing process, we always say K type
thermocouple.
So these are the different types, T type, J type, E type and K type.
So each type has an alloy which is added.
So T type is copper is 40%, constantant is 60% and it is used from minus 200 to 350 degree
Celsius.
So here, so next is iron, J type is iron and constantant which is used from minus 150
to 750 degree Celsius.
Chrome constantant which is used from minus 200 to 1000 degree Celsius and K chrome which
has 90% nickel and 10% chromium and alumel will 94% nickel, 2% aluminum, 3% magnesium
and 1% silicon can be used from minus 200 degree Celsius to 1000 degree Celsius.
The technology is very well known when you go for higher degree temperatures when for
lower degree temperatures it is still a big challenge.
The rare earth metals there are S type, R type.
So S type is platinum, rhodium and platinum percentage from 0 to 1500 degree Celsius and
platinum, rhodium which is used for a combination which is also used to go up to 1500 degree
Celsius.
So most predominantly used one is K type.
Thermopiles which are now getting little bit popular and extension of thermocouple is called
as thermopile.
A thermopile comprises a number of thermocouples connected in series wherein the hot junction
are arranged side by side or in star formation.
So this is a typical thermopile which is made from MEMS structure.
So these are thermocouples.
So in this thermocouple you will have a hot junction, you will have a cold junction, you
will have a hot junction, cold junction, hot junction ok.
So same function so it is cold junction, hot junction fine and then on top of it you will
have infrared absorber layer.
Then photosensitive surface is put on top of it and this one is insulated.
So in an insulation you have this cold junction and hot junction thermocouples and then you
have a basic substrate.
This substrate is made out of silicon.
So this is a number of thermocouples are connected to measure the temperature.
They are connected in series wherein the hot junction are arranged side by side, hot junction
are arranged side by side.
So if you put it in a schematic form, this is your hot junction, this is your cold junction,
you have T1 in the hot junction.
So T2 is here so T1 so it is all attached and then they have a T2 cold junction here
and basically you try to measure the EMF and it is displayed in terms of voltage.
We also have resistance type detector which is otherwise called as RTD.
RTD is a temperature measuring device composed of resistance thermometer element, internal
connecting wire, a protective shell with or without means for mounting a connecting head
or connecting wire or other fittings on both.
An RTD is a temperature sensor that works on the principle of principle that the resistance
of electrical conductivity material is proportional to the temperature to which they are exposed
to.
So here temperature is proportional to the resistance.
The principle of resistance of the electrical conductive wire is proportional to the temperature
to which it is exposed.
So here you keep a rod.
So this is a RTD resistance temperature detector.
So the temperature, the source whatever it is, let me put a source here.
So it hits and then what you get measured is a temperature.
So this is nothing but resistance based temperature measuring device.
The resistant temperature detector, the popularity of platinum is due to the following factors.
Platinum is chemically inert.
It is most expensive also, costlier than gold.
So chemically inert, almost linear relationship with temperature and resistance exist.
So this makes platinum a very good candidate.
The large temperature coefficient of resistance resulting in rapidly measurable values of
resistance, resistance changes due to variation in temperature.
So large temperature coefficient of resistance which results in readily measurable values
of resistance change due to variation in temperature.
The greater stability because of temperature resistance remains constant over a long period
of time.
The greater stability, chemical inertness, large thermal coefficient of expansion, readily
measurable values of resistance change, all these things make platinum a popular choice
for RTD.
What is RTD?
RTD is nothing but resistance temperature detectors.
Compared to the other type of temperature sensors, RTD have the following advantage.
What are the other sensors we studied?
Thermocouple, then pile, thermopiles, okay.
Compared to this, how is RTD better?
The resistance versus temperature, linearity characteristics of RTD are higher.
See, when you try to choose any sensor, we always make sure that the response falls in
the linear range.
Why?
A mathematical equation can be expressed.
Only for that, we always try to operate the entire sensor in the linear range or we find
out the linear range, try to use it only during the linear range.
The resistance versus temperature, linearity characteristics of RTD are higher.
They possess greater accuracy compared to the other two techniques.
They have excellent stability over time.
Then temperature sensitive resistance elements can be replaced very easily, which the other
things cannot be done.
It has to be wiring done, this has done.
And these are the advantage of using RTD over the other temperature measuring devices.
This is how a RTD looks like.
A platinum lead is here.
So this is how it is exposed to the temperature and then it is put inside a protective casing
and inside the protective casing, the lead is wound around a ceramic bobbin, okay.
So the temperature is measured, then this is communicated inside and there is a resistance
element.
These are resistance elements, ceramic bobbin you try to get it.
This is a schematic diagram.
When you look at a original product, you will have a stainless steel, a seal sheet
which is kept around the RTD bulb, this bulb, okay.
Then you have two leads which goes and then here is an adjustable compressing fitting
and inside this you have this lead which goes and we try to measure it.
So this is how a RTD looks like.
You can use it something like a thermometer, take it like a, this will be something like
this, like a pen.
So you can try to push it and then try to get the temperature.
So this is how RTD works or this is how RTD looks.
So the response of RTD, so RT by R0 if you take and with respect to temperature, you
see there is a linear trend for platinum, copper there is a exponential trend or there
is a change in the linearity, nickel it is also there, okay.
This is the best suited.
So the next kind is thermistor, thermocouple, thermopiles.
We studied about resistance, temperature detector.
Now we are trying to go to the next variety or the type is thermistor.
A thermistor is a type of resistor whose resistance is dependent on temperature more than its
standard resistor.
The word in the portmanteau of temperature and resistor is mixed together and we get
a thermistor.
Thermistor are widely used in inrush current limiters, temperature sensors, self-resetting
over current protectors and self-regulating heating element, we use thermistor, okay.
Thermistor is a type of resistor whose resistance is dependent on temperature more than the
standard resistor.
The relationship between the temperature and the resistance is given by this equation where
R equal to R suffix R e to the power beta 1 minus T by 1 minus Tr.
The temperature coefficient of resistance is given by the following equation R T by
dou R by dou T dou R by dou T divided by R which is nothing but beta by T square.
The temperature coefficient of platinum at 25 degree Celsius is this much and for the
thermistor, it is generally rounded off to this much, okay.
It is very low which is 10 times more than the sensitivity when compared to platinum
thermistor.
A variety of ceramic semiconductor material qualify for thermistor among them germanium
coating precise proportional to arsenic, gallium and antimony is the most preferred one.
The temperature what they can measure is minus 250 degree Celsius to 650 degree Celsius.
So this is the relationship for thermistor temperature and resistance.
Liquid in glass thermometer, the next type, this is what is called as LIG.
The LIG thermometer, the thermally sensitive element is a liquid contained in a graduated
glass envelope.
The principle used to measure temperature is that the apparent thermal expansion of
the liquid is measured and we do it.
This is a scale, here is a working liquid which is generally mercury and here is a reference
point and here is a bulb.
So there is also pressure thermometer.
So pressure thermometer are where there is a liquid, there is a bulb, there is a capillary
tube and then this is a boron tube and then this one is attached to a link, it is attached.
So this link in turn is attached to a gear attachment.
So this gear mechanism is attached to a pointer and this tries to show in the graduation what
is the response.
A capillary tube ok, the bulb capillary tube, then a boron tube, then you have a free end,
this is the free end and this free end is attached to a link that has a gear mechanism
this rotates and you show the graduation.
The next type is pyrometer.
Pyrometer is a remote sensing, it is a non contact type, it is a remote sensing thermometer
used to measure the temperature of a surface.
Various forms of pyrometers have historically existed.
In the modern usage, it is a device that from a distance determines the temperature of the
surface from a spectrum of thermal radiation it emits.
A process known as pyrometer or sometimes radiometry is also called.
This is the modern pyrometer which is used to measure the temperature and this was in
the olden days they used to measure the temperature using pyrometer.
So pyrometer is remote sensing thermometer.
In pyrometer, we have E, E is the radiation impinging on the body which is nothing but
watt per meter square, A is the fraction of radiation alpha, alpha is the fraction
of the radiation power absorbed by the body and E is the total emissivity, E is the total
emissivity which is nowadays given in a standard calibration scale or if you want to figure
it out, it is alpha into E divided by E radiation emitted from a body divided by radiation falling
on the body, right.
The Stefan Boltzmann law states that the total energy radiation by a black body is a function
of its absolute temperature only and is proportion to the fourth power of the temperature.
The total energy radiation by a black body is a function of absolute temperature only
and is proportional to the fourth, fourth power of temperature.
So E is equal to alpha times T to the power 4.
According to Stefan Boltzmann law, if two ideal radiations are considered, the pyrometer
not only receives heat from the source, but also radiates heat to the source.
Therefore, the net rate of exchange will be this which is nothing but E is equal to
sigma T p to the power 4 minus T s to the power 4.
T p is the pyrometer received from the heat source and also the radiation to the source.
So, the emissivity and if you try to link emissivity and Stefan Boltzmann, E is nothing
but the emissivity into alpha T to the power 4 is the final equation with Stefan Boltzmann
law.
This is used in pyrometer measurement.
If the emissivity of the surface is known, then the temperature of the body can be determined
provided it can be kept in open.
T is the true temperature and T is the apparent temperature taken with a radiation pyrometer
positioned in such a way that the body is fully viewed, then E is equal to sigma T to
the power 4 which is the apparent temperature.
The pyrometer receives energy that is equivalent to the energy emitted by the perfect black
body radiation at a temperature T. This temperature is lower than the temperature of the body
under consideration.
We know the energy emitted by a non-black body is given by this equation, right and
hence E T suffix A to the power 4 is nothing but T to the power 4.
So, the total radiation pyrometer, the total radiation pyrometer receives all the radiation
from a particular object or of hot body.
The term total radiation includes both the visible and the invisible radiation.
It consists of radiation receiving element and the measuring device.
A mirror type radiation pyrometer as shown in the figure below.
Next we see the here the diaphragm unit along with the mirror is used to focus the radiation
on a thermocouple.
The distance from the mirror and the thermocouple is adjusted for proper focusing.
So, this is how it is.
Total radiation pyrometer looks like this.
These are the diaphragm.
This is a window.
Here is a housing.
So, here is a mirror which is which is polished very well.
Here is a thermocouple and a hole through which you see and then you calibrate it.
So, we see through it.
So, this is there.
So, we adjust the diameter and then we try to measure what is the temperature.
So, the mirror type radiation pyrometer is shown in the figure below.
Here the diaphragm unit along with the mirror is used to focus the radiation of a thermocouple.
The distance between the mirror and the thermocouple is adjusted for proper focusing and you get
it.
So, what is the advantage?
It is a totally non-contact type.
You can measure the temperature.
By you focus it on the thermocouple, you get the temperature.
It gives you a very quick response.
The high temperature measurement can be accomplished.
So, total so, you can see here another type.
A total radiation pyrometer also have certain disadvantage such as the error in temperature
measurement are possible due to emission of radiation at the atmosphere.
For example, this is a furnace or a hot body.
Then the temperature which is seen, which is get the infrared lens is there.
Then it goes to a mirror.
Then here it is taking to a thermopile.
Then you have a mirror, you have a lens and then it goes to the eyepiece and you start
locating it.
The incoming radiation by focusing the lens on the body, you try to get the eyepiece and
you try to measure the temperature displacement.
So, the radiation also has a certain disadvantage such as the errors in temperature measurement
are possible due to emission of radiation to the atmosphere.
So, what we say is here also you get losses.
Because of these losses, you might get the temperature.
So, optical pyrometer.
So, optical pyrometer works on disappearing filament principle.
In order to measure the temperature, the brightness generated by the radiation of an unknown source
or a hot body whose temperature is to be determined is compared with the reference lamp.
So, you check the with the reference lamp and then you try to see at what temperature
the filament disappears and this is the principle we use for optical pyrometer.
So, optical pyrometer at temperature source, you will have objective lens.
Then you have a screen, you have a reference bulb and then you have a red filter, you watch
through it.
Now, this bulb is given temperature.
So, now what you do is you try to look at the heat source, adjust the lenses or the
resistance here and make sure that the light intensity and the temperature, the image gets
disappeared and based on that you try to measure the output voltage and then you try to measure
the temperature ok.
A rheostat is there, you adjust it, a battery and then this is used for this.
So, you adjust it such that the brightness is adjusted.
So, advantage a simple assembly, it provides to very high accuracy of 5 degree Celsius.
There is no need for any direct body contact with the optical pyrometer.
Applications, it is used to measure liquid metal.
For example, when you may want to measure a crucible temperature, we try to use a crucible
temperature.
In steel industry or iron industry or copper industry, we always use optical pyrometer
for measurement and it is used to measure furnace temperatures.
So, here is a optical pyrometer.
So, this is a bright, the brightness is here and this is a filament.
So, filament is dark that is cooler than the temperature source.
The filament is bright that is hotter than the temperature source.
The filament disappears thus the this is equal to the brightness of the filament and
the temperature source.
So, this is what is called as disappearing filament principle.
So, fiber optic pyrometer, the fiber optic pyrometer essentially comprises a fiber optic
cable and an array of components such as probe, sensor and receivers, terminate terminals,
lens, couplers and connectors.
A fiber optic cable is used to transmit radiation from a black box cavity to the spectrometric
device that computes the temperature.
So, this is the technique with which fiber optics pyrometer works.
So, it tries to transmit radiation from a black box cavity to a spectrometric device
that computes the temperature and lets you know.
They can be employed when the path of sight of the target is unclear, we use fiber optic
pyrometer.
When accuracy is a critical parameter, then we can use this measurement.
This can be used when the target whose temperature is to be determined is subjected to physical
or a chemical change, right.
When from the solid it goes to liquid and all, we can use this fiber optic cable.
The temperature is as low as 100 degrees can be measured.
Then it is infrared pyrometer.
So, this is infrared pyrometer when there is a hot body.
So, the infrared pyrometer it emits.
So, here you can see the infrared getting transmitted, getting reflected, getting absorbed,
right.
So, an infrared pyrometer is a non-contact type sensor that can detect infrared radiation
from the heat body.
It is essentially measures the amount of radiation emitted by a object.
The infrared pyrometer are ideally suited for high temperature measurements.
So, with this we come to the end of this chapter on temperature measurement.
We started with an introduction to temperature measuring, various methods of temperature
measurements, thermocouple, different types of thermocouple, thermistor, pyrometer and
different types of pyrometer.
So, thank you very much.