Namaskar. So, in this week we discussed about linearity of the circuit and then we discussed
about the source transformation and in last class we discussed about duality. So, with
the reference of these three important properties of the circuit, let us start the network theorem
which is called as Thevenin's theorem.
And this Thevenin's theorem is very important for the circuit point of view. What happens
in generally that the particular element in a circuit which is variable, generally that
particular element is considered as a load and while the other elements are fixed. You
can take typically the example of household outlet terminal that may be connected to different
appliances. So, what happens when you plug in your appliance in the house, you will analyze
the voltage and current parameters of that appliance while neglecting the circuit which
is outside the particular plug point. So, what happens that you will analyze the
circuit parameters like voltage and current while doing the analysis for various appliances.
So, various appliances will have their own current level while voltage level will almost
remain same in all the appliances. So, in that scenario if you are doing the study for
appliances how you will analyze the circuit. If you see the conventional way of circuit
analysis what you have to do, you have to come take the complete ah power system network
that is very large in size and you will end up having hundreds of mesh networks or hundreds
of nodes in the network and if you start doing the ah mesh analysis or nodal analysis it will
take ah lot of time and it will be ah almost impossible to do it in a reasonable time frame.
So, to address that problem the alternate way is that you can ah represent the equivalent of the
circuit of the power system network which is external to that particular plug point and then
analyze only that particular load or that particular ah variable element in which you
are basically interested. So, to solve that problem we use the theorem called Thevenin's
theorem because it provides a technique by which the fixed part of the circuit is replaced by its
equivalent circuit. Now, according to Thevenin's theorem the linear circuit in the left of the
figure which is shown below can be replaced by that shown in the right. So, if you can imagine
that these are the two terminals of your ah plug point in the house external to that you will see
as a linear circuit. So, you have to keep in mind that Thevenin's theorem work well when the circuit
is linear. So, you will assume that the circuit which is ah outside your plug point is the linear
circuit and you will replace that particular segment with one equivalent circuit where you
will have one voltage source and one resistance. So, in that way the load which you are analyzing
for various circuit ah elements like the variables like voltage and current you will keep that load
connected with the equivalent of the circuit which is external to that particular load terminal.
So, that circuit to the left of this the node a b is called as Thevenin equivalent circuit. This
concept was developed by M. Leon Thevenin in 1883 who was a French telegraph engineer. So,
what does Thevenin's theorem says a linear two terminal circuit can be replaced by an
equivalent circuit consisting of a voltage source V th in series with register R th where V th is
the open circuit voltage at the terminals and R th is the equivalent resistance at the terminals
when the independent sources are turned off. So, when we calculate the value of R th we
will create the equivalent circuit by switching off the independent sources. Switching off the
independent source means if you have a independent voltage source you will short circuit and if you
have a independent current source you will open circuit. So, the problem with the ah Thevenin
theorem is that you have to identify the ways how you will calculate the value of V th and R th.
Now, if you assume that there are two circuits which are shown below are equivalent that means
there is an unknown ah linear network where we do not know what is inside and outside that
linear two terminal circuit we have connected a load across terminals A B. So, voltage across
terminal A B is V and current flowing into the load from the external circuit is current I. So,
if we replace the external circuit with Thevenin equivalent that is voltage Thevenin voltage V th
in series with one resistance R th and if you have V I characteristic at this terminal same
while ah taking the load out then these this particular circuit will be considered as a
equivalent of that external circuit. So, you have to keep in mind that these circuits
are said to be equivalent only when you have voltage current relationship same for both
of the circuit at their terminal. Now, when the terminal A B open circuited by removing
the no current will flow through the load. Now, this open circuit voltage across the
terminal A B ah in the circuit on the left must be equal to voltage source V th in the
circuit on the right. So, that means, that if you remove load from here there would be some
voltage across terminal A B and if you remove load from here there will be same voltage which
would be coming across A B that is V. So, using this particular equivalency you can identify the
voltage of V th how because V th is open circuit voltage across the terminals when you remove the
load you will see some voltage let us say it is V o V o c. Similarly, for the Thevenin equivalent
that is here if you remove the load you will again get the value V o c and these 2 V o c's
are same because this V o c would be nothing, but V th because when it is open circuited there would
be no current flowing in this particular segment right. So, if you remove these ah the load no
current will be flowing. So, in that case this particular voltage would be nothing, but V th.
So, what we can say that the linear 2 terminal circuit open circuit voltage across terminal A
B would be equal to V th. Now, again with the load disconnected because the terminal A B
then you have open circuited the terminal A B all independent sources you need to turn off.
Turning off the independent sources means if you have the voltage source inside the terminal you
will replace it with the short circuit and if you have current source you will replace it with the
open circuit. So, in that case what will happen that this linear 2 terminal circuit would be
nothing, but a dead circuit because there is no source available. Now, the equivalent resistance
which you will ah measure between these 2 terminal A and B would be equal in both of the cases. Both
of the cases means the case 1 where you have linear 2 terminal circuit you will take all the
sources of you will measure the R th here. Similarly, if you measure R th here it will
be this value because in that case this would be short circuited. So, in that case whatever
the resistance you will see in both of the cases the input resistance which you will see across the
linear circuit with all independent sources at equal to 0 would be equal to R th.
So, with these 2 ah conditions you can find the value of the important parameters which
are required for Thevenin theorem which are V th and R th. Now, to find out the value of R th there
are 2 different cases. What are the 2 different cases? First case is that if the network has no
dependent sources we can simply turn off all the independent sources like we can ah make the
voltage as short circuit and current source as open circuit and then R th is the input resistance
of the network looking between terminal A and B. So, that means, that whatever the input resistance
you will see from terminal A B while keeping all independent sources equal to 0 that will give you
simply the Thevenin resistance. Now, in case 2 when the network has dependent
sources also we cannot switch off the dependent sources because they are anyway controlled by
some circuit variable. So, what will happen in that case? You can simply turn off only the
independent sources. So, you will only switch off independent sources while keeping dependent
sources on and then you will analyze the circuit how you have to simply apply one voltage V naught
at the terminal A B and determine the current I naught. So, what will happen in that case?
Here the circuit with all independent sources equal to 0 are present and the dependent sources
are also available. So, in that case you have to apply one voltage V naught across the terminal
of A B and measure the value of current I naught. Then V naught divided by I naught would be giving
you the value of Thevenin equivalent resistance that is R th. Alternatively the R th can also be
measured by inserting a current source. So, instead of voltage source across these two terminals you
will apply one current source. Now, what you have to do? When you apply the current source instead
of current which you have measured here you have to measure the voltage across terminals A B.
What will happen in that case? Again the R th would be given as the voltage across terminals
A B divided by the current supplied by current source. So, in that case the R th would be nothing
but V naught upon I naught. Now, in both of the cases you can use any one of the method in both
of the cases you will get the same value of R th. So, you will get eventually the same result.
Now, it often occurs that the R th which you calculate will become negative. So,
it implies that the circuit is delivering power. So, you need not to worry whether your solution
is correct or not if your R th is negative. So, sometimes R th would be negative and it
is also possible when the circuit is having dependent sources.
Now, this theorem is very important in the circuit analysis why? Because it helps in
simplifying the circuit. So, whatever the larger network outside the area of your study is present
you will simply equivalent that network which is outside the area of your study by Thevenin
equivalent. So, you will replace with V th and R th and you will use that particular equivalent
circuit to analyze the circuit which is of your interest. So, that is why this the Thevenin
equivalent replacement technique is very powerful tool in our circuit design.
Now, as we have discussed that linear circuit with variable load can be replaced by Thevenin
equivalent excluding the load. Now, this equivalent network will behave as same way as the external
circuit is behaving because you are creating the Thevenin equivalent of the external circuit
by keeping V i characteristic equivalent. So, how you will calculate the different ah
load voltage and load current values? Let us take one sample circuit and we will try
to find out the value of current flowing through the load resistance R L.
Now, what you will do? The circuit external to your load R L would be replaced by its
Thevenin equivalent that is V th and R th. So, what will happen in that case the circuit
ah R L this would be your load and there will be one resistance R th would be the Thevenin
equivalent resistance and it will both would be connected through voltage source which
is nothing but Thevenin voltage. So, this would be the equivalent circuit of your the
original circuit where the linear circuit is not known to us we are just simply replacing
it with the Thevenin equivalent. Now, how we will calculate the value of current
I L? Simply the value of current I L would be the voltage V th divided by R th plus R
L. So, that is simply the Kirchhoff voltage law you can apply and get the value of current
I L. Now, the voltage across load that is V L in this case would be I L into R L and
you will simply get the value of V L as V th into R L divided by R th plus R L.
So, when you get the values of R th and V th you can easily find out the variables across
the load that is voltage and current. Now, if you have multiple cases or multiple loads
through which you want to find out the current and across ah those loads voltages you need
not to change anything in this ah circuit ah that is R th and V th you have to just
keep on changing the loads across terminal A and B. So, based on the resistance of the
load your load current will keep on changing. So, in this way it will be very handy to process
the multiple cases when these are connected to two terminals.
Now, let us understand this particular aspect with the help of one example. Now, you see
ah there is a circuit given in this figure we need to find out Thevenin equivalent to
the left of terminal A B. So, these are the terminals A B and we have to find out the
current through the load when R L is equal to either 6 ohm or 36 ohm. So, this is the
variable load it will keep on changing. So, you need to find out the value of ah current
through the load under various loading conditions. So, for this particular case we are considering
two different loading conditions where R L is 6 ohm and 36 ohm.
Now, how we will do we find the Thevenin resistance by turning off the 32 volt source. Now, when
you replace the voltage source it will become short circuited and we have another source
which is current source that is 2 ampere current source. So, we will simply make it
open circuit. So, what will be the updated circuit in that
case we left with only the 4 ohm resistance in parallel with 12 ohm resistance and then
finally, the parallel combination in series with 1 ohm resistance. So, what happened when
you make the equivalent circuit the resistance which you will see through these particular
terminals that is A and B you will get the value of R th as 4 ohm because the parallel
combination of these two resistances would give you 3 ohm plus 1 ohm in series.
So, finally, the R th value is 4 ohm. Now, next step is finding out the value of Thevenin
voltage. Find the value of Thevenin voltage we have to consider the circuit and whatever
we discussed in previous classes we have to just recollect ah our study specially the
mesh analysis which we discussed because here it is you can see that you can create
two meshes you can apply match current I 1 and I 2 across these two meshes and you need
to find out the voltage V th across terminal A B.
Now, important thing which you need to see from this particular circuit is that current
I would be 0. Now, when current I is 0 the V th would be applied straight away across
this that means, the same would be applied across this because all are in parallel. So,
V th would be nothing but the voltage which is coming at this particular node. So, V th
would be the value of this node. Now, let us apply the mesh analysis for these
two loops. For loop 1 when you apply the mesh analysis what you will get? You will get ah
when you start from here you will get minus 32 volt because it is the current mesh current
is flowing from minus 2 plus this will be minus 32 plus 4 I 1 then 12 I 1 minus I 2
because I 1 would be flowing in this direction I 2 would be flowing in this direction. So,
net current would be I 1 minus I 2. So, this will become 12 into I 1 minus I 2 and that
would be equal to 0. So, this is the first equation which you get from mesh 1.
Now, if you see the ah mesh 2 you can straight away see that current I 2 is nothing but opposite
of the current source current value that is 2 ampere. So, you can simply write I 2 is
nothing but minus of 2 ampere. So, now, you have got two equations I 2 you have straight
away found next is you have to just place the value of I 2 in this equation and you
will get current I 1 as 0.5 ampere. Now, as you have got value of current I 1 and I 2
what you have to do? V th would be nothing but 12 into I 1 minus I 2. So, you can simply
write the value of V th as I 1 minus I 2 simply put the value of I 1 and I 2 you will
get V th as 30 volt. Now, instead of mesh analysis you can also
apply nodal analysis as well. So, if you apply the nodal analysis at this node because this
is the node where you are seeing the voltage V th. So, if you apply nodal analysis that
means, that you have to use Kirchhoff current law here. So, what will happen? You will simply
see what are the various currents flowing into the node and equate it equal to 0 because
total sum of current at that particular node would be 0. So, what would be the current
coming inside from left that would be 32 minus V th divided by 4 ohm. So, you have got first
term of the equation then next is 2 ampere current which is flowing in this direction.
So, you can simply put the value of 2 ampere third is the current which is flowing in this
direction. So, the current flowing in this direction would be sum of these two currents.
So, finally, this would be equal to V th by 12 because the voltage at this is V th and
the resistance connected between reference node and the node in ah in the question is
12 ohm. So, you will simply get this equation when you apply the nodal analysis.
Now if you rearrange the terms and simplify it you will again get the value of Thevenin
ah voltage that is 30 volt. So, in that way either you apply mesh analysis or the nodal
analysis in both way you will get the Thevenin voltage same. Now your equivalent circuit
of the particular figure which we discussed is 30 volt that is V th and 4 ohm that is
R th and across the terminal A B you will apply variable resistance where you have to
find out the value of current load current for 6 ohm and 36 ohm.
So, what you will do you will just put the value of R L when R L is equal to 6 ohm you
will simply get I L is nothing, but the you will simply apply Kirchhoff voltage law and
you will get the value of current I L as 3 ampere. Similarly if R L is 16 ohm you will
get current I L as 1.5 ampere when you will replace R L with 36 ohm you will get I L is
nothing, but 30 divided by the value 40. So, you will get 0.75 ampere. So, in this way the
benefit which you will get is that you will keep the left of this particular ah segment left of
the terminal A B same and you will keep on varying the load resistance and you can find out the value
of load current when various load resistances are given. So, in this way you can calculate the
value of the load current for various loading conditions. So, we stop here with the initial
discussion on the ah Thevenin theorem when we considered only the independent voltage or
current sources. In next session we will discuss the case where we have dependent voltage or
dependent current source is all is also available in the circuit. In that case how we will analyze
the circuit. Thank you.