OMICRON’s application engineer, Jakob Hämmerle, offers his insight into the importance of power transformer testing. Power transformers are the central hub in the field of energy distribution and transmission. As such, their condition is critical for reliable, fault-free operation. Any failures can have serious consequences. Therefore, we have developed the CPC 100 multifunctional measurement system covering a wide range of important electrical power transformer tests. 00:00 - Introduction 00:19 - Importance of regular diagnostic testing and condition assessment 00:27 - Overloads of grid sections 00:54 - The ideal multifunctional testing solution 01:36 - Automated 3 phase and tap changer testing 02:02 - Different operating modes to meet your personal preferences 02:21 - Summary: Here are 3 things to keep in mind ☝️ Learn more about CPC 100 on our website: https://www.omicronenergy.com/en/cpc100-electrical-science/ ☝️ Learn more about power transformer testing on our website: https://www.omicronenergy.com/en/application/offline-testing/power-transformer/ ▶️Interested in power transformer testing? – Watch all of our videos: https://youtube.com/playlist?list=PLzmbZeI1bhu_22G4fDZqRuRPdn3l6I8b7 _ Would you like to find out more about OMICRON, our passions, and our products? 🌐Check out our website: https://www.omicronenergy.com/en Or follow us on social media 👉On LinkedIn: https://www.linkedin.com/company/omicron-electronics/ 👉On our podcast Energy Talks: https://www.omicronenergy.com/en/energy-talks-podcast/ 👉On YouTube: https://www.youtube.com/channel/UC2F35zz5XMoi1vbXrMgEyGQ
Lukas Klingenschmid, product manager for our CPC 100 multifunctional test system, gives an insight about the importance of asset maintenance. Power plant assets like generators, transformers, circuit breaker as well as protection and control systems need to be in healthy state to fulfill this promise. He explains the advantages of CPC 100, the multifunctional substation test system to identify the health status of high-voltage equipment easily, before hazards occur. TIMESTAMPS: 00:00 – Importance of asset maintenance 00:33 – CPC 100 test system 01:04 – Testing solutions 01:36 – Modular test system 02:27 – PTM Software 02:48 – Recap 03:30 – Outro ☝️ Learn more about CPC 100 on our website: https://www.omicronenergy.com/en/products/cpc-100/ ▶️Interested in Testing Primary Assets? – Watch all of our videos: https://youtube.com/playlist?list=PL5F0FD9968998E6E7 _ Would you like to find out more about OMICRON, our passions, and our products? 🌐Check out our website: https://www.omicronenergy.com/en Or follow us on social media 👉On LinkedIn: https://www.linkedin.com/company/omicron-electronics/ 👉On our podcast Energy Talks: https://www.omicronenergy.com/en/energy-talks-podcast/ 👉On YouTube: https://www.youtube.com/channel/UC2F35zz5XMoi1vbXrMgEyGQ
Ari Tirroniemi, an application engineer at #OMICRON, explains why grounding systems are essential for the safe and reliable operation of electrical power systems. Improper #grounding systems may not be able to carry total fault currents. This may cause damage to primary assets such as #transformers. It may even harm or destroy the functionality of electronic devices, like protection relays and communication equipment. 00:00 - Introduction 00:08 - Grounding systems are an essential part of electrical power systems. 00:37 - Dangerous step and touch voltages can occur inside and outside a substation. 00:50 - Use CPC 100 and the coupling unit, CP CU1 to verify the condition of your grounding system. 01:16 - Safety: Line fault currents of up to 30.000 amperes are safely diverted to the ground. 01:28 - With our solution, the assessment is carried out according to IEC and IEEE standards. 01:35 - The CPC 100 uses the Frequency Selective Method (FSM) to inject a test current into the grounding system to provide very reliable results. 01:55 - The test current can be injected via power line injection or a current probe injection. 02:13 - With our hand-held measuring device HGT1, resulting voltages of the injection can easily be measured and recorded. 02:47 - Measurement points can be combined with pictures or maps, including GPS location, to obtain proper documentation. 03:02 - Summary: Here are 3 things to keep in mind. ☝️ Learn more about CPC 100 on our website: https://www.omicronenergy.com/en/cpc100-electrical-science/ ☝️ Learn more about grounding-systems on our website: https://www.omicronenergy.com/en/application/offline-testing/grounding-systems/ ▶️Interested in Testing Primary Assets? – Watch all of our videos: https://youtube.com/playlist?list=PL5F0FD9968998E6E7 _ Would you like to find out more about OMICRON, our passions, and our products? 🌐Check out our website: https://www.omicronenergy.com/en Or follow us on social media 👉On LinkedIn: https://www.linkedin.com/company/omicron-electronics/ 👉On our podcast Energy Talks: https://www.omicronenergy.com/en/energy-talks-podcast/ 👉On YouTube: https://www.youtube.com/channel/UC2F35zz5XMoi1vbXrMgEyGQ
OMICRON’s product manager, Fabian Öttl, offers his insight into the importance of stator core measurements. The reliable operation of rotating electrical machines, whether generators or motors, is essential for continuous power generation and critical industrial processes. Our stator core measurement upgrade option allows you to reliably detect interlamination imperfections in the stator core of rotating electrical machines. 00:00 - Introduction 00:25 - rotating machines are composed of multiple stacked layers 00:36 - local eddy currents 00:47 - low flux measurement method 01:26 - CPC 100 acts as excitation source and measurement device 01:54 - higher usability through the semi-automatic sensor movement 02:12 - manual mode 02:23 - controlled by Primary Test Manager software PTM 02:53 - Summary: Here are 3 things to keep in mind ☝️ Learn more about CPC 100 on our website: https://www.omicronenergy.com/en/cpc100-electrical-science/ ☝️ Learn more about testing ground systems on our website: https://www.omicronenergy.com/en/application/offline-testing/grounding-systems/ ▶️Interested in Testing Primary Assets? – Watch all of our videos: https://youtube.com/playlist?list=PL5F0FD9968998E6E7 _ Would you like to find out more about OMICRON, our passions, and our products? 🌐Check out our website: https://www.omicronenergy.com/en Or follow us on social media 👉On LinkedIn: https://www.linkedin.com/company/omicron-electronics/ 👉On our podcast Energy Talks: https://www.omicronenergy.com/en/energy-talks-podcast/ 👉On YouTube: https://www.youtube.com/channel/UC2F35zz5XMoi1vbXrMgEyGQ
The CPC 100 is a powerful multi-functional primary test set for substation commissioning and maintenance. It can generate up to 800 amps AC, up to 2000 volts AC at frequencies ranging from 15 to 400 hertz, and up to 400 amps DC. Using power electronics instead of copper & iron variacs allows combining all of these functions into a device that can be carried by one person." Get more Information about CPC 100: https://www.omicronenergy.com/en/products/cpc-100/ Interested in Testing Primary Assets? – Watch all of our videos: https://youtube.com/playlist?list=PL5F0FD9968998E6E7
The CPC can either be operated manually, or by using its built-in testing know-how, either directly from the front panel, or by remote-control from a laptop. For each task, QUICK mode, the test cards and Primary Test Manager provide easy, efficient and comprehensive ways to operate the CPC 100, corresponding to the individual preference. Get more Information about CPC 100: https://www.omicronenergy.com/en/products/cpc-100/ Interested in Testing Primary Assets? – Watch all of our videos: https://youtube.com/playlist?list=PL5F0FD9968998E6E7
The compactness of a gas insulated switchgear, or GIS, provides a lot of advantages but it also challenges the insulation between the high voltage parts and its surrounding. Thus, high voltage tests are carried out on GIS prior to switching them onto the grid. For testing at mains frequency, large and heavy test transformers are needed. A more lightweight and smaller alternative is a test system which uses resonance frequency. Watch how the High Voltage Resonance Test System from OMICRON, with the CPC 100 and the CP RC2, is used to prove the dielectric integrity of a GIS with a rated voltage of 123 kV during a high potential test (HIPOT test). ☝️ Learn more about CPC 100 on our website: https://www.omicronenergy.com/en/products/cpc-100/ ☝️ Learn more about test systems on our website: https://www.omicronenergy.com/en/products/cp-rc/ ▶️Interested in Testing Primary Assets? – Watch all of our videos: https://youtube.com/playlist?list=PL5F0FD9968998E6E7 _ Would you like to find out more about OMICRON, our passions, and our products? 🌐Check out our website: https://www.omicronenergy.com/en Or follow us on social media 👉On LinkedIn: https://www.linkedin.com/company/omicron-electronics/ 👉On our podcast Energy Talks: https://www.omicronenergy.com/en/energy-talks-podcast/ 👉On YouTube: https://www.youtube.com/channel/UC2F35zz5XMoi1vbXrMgEyGQ
Power transformers transform electrical energy from one voltage level to another - by stepping voItages up for transmission to minimize losses, or down for distribution. During regular operation, and in particular during an electrical fault, power transformers are subject to electrical, mechanical, thermal, and environmental stresses. Therefore, utilities and service providers test power transformers, in order to assess their condition, schedule maintenance work and plan their replacement. Interested in power transformer testing? – Watch all of our videos: https://youtube.com/playlist?list=PLzmbZeI1bhu_22G4fDZqRuRPdn3l6I8b7 Interested in testing primary assets? – Watch all of our videos: https://youtube.com/playlist?list=PL5F0FD9968998E6E7 More Information about CPC 100: https://www.omicronenergy.com/en/products/cpc-100/
OMICRON experts discuss the idea behind the CPC 100 and its multifunctional uses for different applications such as power transformers, current & voltage transformers, grounding systems and gas insulated switchgear. Find more details about CPC 100 on our website: https://www.omicronenergy.com/en/products/cpc-100/ Interested in Testing Primary Assets? – Watch all of our videos: https://youtube.com/playlist?list=PL5F0FD9968998E6E7
In the factory, the transformer ratio of each tap and the vector group are verified during production and acceptance testing. On site, ratio and magnetization current measurements are performed in order to assess possible winding damage, such as short circuits between windings or between turns. With the CPC 100, the ratio and magnetization current or excitation current can be measured at the same time. Interested in power transformer testing? – Watch all of our videos: https://youtube.com/playlist?list=PLzmbZeI1bhu_22G4fDZqRuRPdn3l6I8b7 Interested in testing primary assets? – Watch all of our videos: https://youtube.com/playlist?list=PL5F0FD9968998E6E7 Get more Information about CPC 100: https://www.omicronenergy.com/en/products/cpc-100/
In the factory, winding resistance is measured in order to assure proper manufacturing and calculate conductor losses. On site, this measurement is performed to evaluate possible winding damage, such as short circuits between windings or between turns, open circuits, contact problems and to assess the condition of the tap changer. Winding resistance measurement is one of several methods of transformer diagnostics offered by the multifunctional CPC 100. Interested in power transformer testing? – Watch all of our videos: https://youtube.com/playlist?list=PLzmbZeI1bhu_22G4fDZqRuRPdn3l6I8b7 Interested in testing primary assets? – Watch all of our videos: https://youtube.com/playlist?list=PL5F0FD9968998E6E7 More Information about CPC 100 on our website: https://www.omicronenergy.com/en/products/cpc-100
When manufacturers perform ratio and winding resistance tests at the end of the production process or during factory acceptance testing, time is costly and performing such tests efficiently is crucial. When performing diagnostic tests on site, there's also a limited window of time. The CPC 100 and the CP SB1 switchbox make ratio and winding resistance measurements efficient by avoiding climbing up and down the transformer repeatedly and reducing connection errors. Interested in power transformer testing? – Watch all of our videos: https://youtube.com/playlist?list=PLzmbZeI1bhu_22G4fDZqRuRPdn3l6I8b7 Interested in testing primary assets? – Watch all of our videos: https://youtube.com/playlist?list=PL5F0FD9968998E6E7 Get more Information about CPC 100: https://www.omicronenergy.com/en/products/cpc-100/
The condition of the bushings and the overall insulation of power transformers can be investigated by measuring the capacitance and dissipation factor, also known as the tangent delta, or power factor. Aging and decomposition of the insulation, or the ingress of water, increases the losses and thus more energy is turned into heat in the insulation. The level of this dissipation is expressed by the dissipation factor or power factor. The CPC 100 together with the CP TD1 can measure the capacitance and dissipation factor or power factor in laboratories, test fields, and on site. Interested in power transformer testing? – Watch all of our videos: https://youtube.com/playlist?list=PLzmbZeI1bhu_22G4fDZqRuRPdn3l6I8b7 Interested in testing primary assets? – Watch all of our videos: https://youtube.com/playlist?list=PL5F0FD9968998E6E7 Get more Information about CPC 100 on our website: https://www.omicronenergy.com/en/products/cpc-100/
Power plants and substations are the major components of the energy system. Aside from power transformers, the main parts of such a plant include instrument transformers, the protection and control system, as well as switching elements like circuit breakers and disconnectors. For a reliable supply of electricity, the correct operation of all individual components and their seamless interaction has to be assured - during the entire lifecycle of the plant. More Information about CPC 100 on our website: https://www.omicronenergy.com/en/products/cpc-100/ Interested in Testing Primary Assets? – Watch all of our videos: https://youtube.com/playlist?list=PL5F0FD9968998E6E7
During commissioning, several tests on current and voltage transformers need to be performed to identify manufacturing errors or transportation damages, to verify correct installation and wiring and to measure the secondary burden. If problems occur during the operation of the plant, further tests will be performed to identify the cause of the error. With the CPC 100, many of these electrical tests can be performed on current transformers and voltage transformers with one single device, saving test time and labor costs. Interested in Instrument Transformer Testing with CPC 100? – Watch more videos: https://youtube.com/playlist?list=PLzmbZeI1bhu-7ubPhQI6RvaqxSVzLoGS- Interested in Testing Primary Assets? – Watch all of our videos: https://youtube.com/playlist?list=PL5F0FD9968998E6E7 More Information about Instrument Transformer Testing on our website: https://www.omicronenergy.com/en/application/offline-testing/instrument-transformer-testing/
Protection and control systems have to be integrated correctly in order for a substation or power plant to work reliably: All signals must be connected with the correct polarity from the instrument transformers to the automation units, meters, and protection relays and from the relays' trip contacts to the circuit breakers. To assure the correct function of the protection system, each of its components is tested, as well as their interaction. The multiple functions of the CPC 100 allow it to be used to commission protection systems, identify faults and perform troubleshooting. More Information about CPC 100 on our website: https://www.omicronenergy.com/en/products/cpc-100/ Interested in Testing Primary Assets? – Watch all of our videos: https://youtube.com/playlist?list=PL5F0FD9968998E6E7
A station's switching apparatus and its connections have to handle load currents in the range of hundreds or thousands of amps. Low resistance values at all connection points - circuit breaker and disconnector contacts as well as any joint - assure low power dissipation. Keeping the equipment's temperature within its specifications is a precondition for normal and correct operation over its expected lifetime. The low contact resistance of circuit breakers and disconnector switches as well as any joints can be confirmed by micro resistance measurement. More Information about CPC 100 on our website: https://www.omicronenergy.com/en/products/cpc-100/ Interested in Circuit Breaker testing with CPC 100? – Watch more videos: https://www.youtube.com/playlist?list=PL5F0FD9968998E6E7
In stations with automation systems according to IEC 61850, network technologies are used for different types of information exchange. Binary information like switch positions or switching commands can be transmitted via the substation network. Analog voltage and current values can also be transmitted. From instrument transformers or sensors, the merging unit collects the measured values, merges these sampled values into a data stream belonging to one feeder, and publishes them to the substation network. The CPC 100 can test the ratio and polarity of instrument transformers in IEC 61850 applications. More Information about CPC 100 on our website: https://www.omicronenergy.com/en/products/cpc-100/ Interested in Testing Primary Assets? – Watch all of our videos: https://youtube.com/playlist?list=PL5F0FD9968998E6E7
Meet the Dream Team from OMICRON for off-line insulation testing up to 15 kV at rated frequency on all types of motors and generators. This flexible and modular solution can be used for testing a number of electrical parameters, including insulation capacitance and dissipation/power factor, DC winding resistance, contact resistance and impedances. You can also use it for voltage withstand tests and as a high-voltage (HV) source for partial discharge measurements. The compact and lightweight solution replaces the need for large and heavy HV source equipment, and it is ideal for testing in small spaces. ☝️ Learn more about CPC 100 on our website: https://www.omicronenergy.com/cpc100 ▶️Interested in Testing Primary Assets? – Watch all of our videos: https://youtube.com/playlist?list=PL5F0FD9968998E6E7 _ Would you like to find out more about OMICRON, our passions, and our products? 🌐Check out our website: https://www.omicronenergy.com/en Or follow us on social media 👉On LinkedIn: https://www.linkedin.com/company/omicron-electronics/ 👉On our podcast Energy Talks: https://www.omicronenergy.com/en/energy-talks-podcast/ 👉On YouTube: https://www.youtube.com/channel/UC2F35zz5XMoi1vbXrMgEyGQ
Christoph Engelen, product manager of the CPC Sync function, gives an insight of how the multifunctional test system CPC 100 becomes a powerful, modular and mobile high-voltage source. ☝️ Learn more about CPC 100 on our website: https://www.omicronenergy.com/cpc100 ▶️Interested in Testing Primary Assets? – Watch all of our videos: https://youtube.com/playlist?list=PL5F0FD9968998E6E7 _ Would you like to find out more about OMICRON, our passions, and our products? 🌐Check out our website: https://www.omicronenergy.com/en Or follow us on social media 👉On LinkedIn: https://www.linkedin.com/company/omicron-electronics/ 👉On our podcast Energy Talks: https://www.omicronenergy.com/en/energy-talks-podcast/ 👉On YouTube: https://www.youtube.com/channel/UC2F35zz5XMoi1vbXrMgEyGQ